Advertisement

Table of Contents

- - - - - - - - - - - - - - - - - - - - - - - 2
Introduction- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Overview - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 2
Display - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
Insert batteries - - - - - - - - - - - - - - - - - - - - - - - - - - - - 3
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Switching ON/OFF - - - - - - - - - - - - - - - - - - - - - - - - - 4
Clear - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Message Codes - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Adjusting measuring reference - - - - - - - - - - - - - - - - - 4
Distance unit setting - - - - - - - - - - - - - - - - - - - - - - - - 4
Beep ON/OFF- - - - - - - - - - - - - - - - - - - - - - - - - - - - - 4
Measuring single distance - - - - - - - - - - - - - - - - - - - - 5
Permament measuring- - - - - - - - - - - - - - - - - - - - - - - 5
Area- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
Volume- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6
Pythagoras (2-point) - - - - - - - - - - - - - - - - - - - - - - - - 7
Pythagoras (3-point) - - - - - - - - - - - - - - - - - - - - - - - - 7
Minimum Tracking - - - - - - - - - - - - - - - - - - - - - - - - - - 8
Maximum Tracking - - - - - - - - - - - - - - - - - - - - - - - - - 8
- - - - - - - - - - - - - - - - - - - - - - - - - - 9
- - - - - - - - - - - - - - - - - - - - - - - - 10
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 10
- - - - - - - - - - - - - - - - - - - - - 10
Areas of responsibility - - - - - - - - - - - - - - - - - - - - - - 10
Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11
- - - - - - - - - - - - - - - - - - - 5
Prohibited use - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Hazards in use - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Limits of use - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Disposal - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -11
Electromagnetic Compatibility (EMC) - - - - - - - - - - - -11
FCC statement (applicable in U.S.) - - - - - - - - - - - - -12
Laser classification- - - - - - - - - - - - - - - - - - - - - - - - -12
Labelling - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -12
EC Declaration of Conformity - - - - - - - - - - - - - - - - -13
Stabila LD 320
EN
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LD 320 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stabila LD 320

  • Page 1: Table Of Contents

    Areas of responsibility - - - - - - - - - - - - - - - - - - - - - - 10 Permitted use - - - - - - - - - - - - - - - - - - - - - - - - - - - - 11 Stabila LD 320...
  • Page 2: Instrument Set-Up

    Pythagoras/ reference / Important paragraphs which must be adhered to in practice Min./Max. Unit as they enable the product to be used in a technically Tracking correct and efficient manner. Clear / Off Stabila LD 320...
  • Page 3: Display

    Instrument Set-up Display Insert batteries To ensure a reli- able use, do not use zinc-carbon Battery Pythagoras batteries. Change batter- ies when battery Area / symbol is flash- Volume ing. Measuring reference Info Min/Max Measuring Units Main line Stabila LD 320...
  • Page 4: Operations

    Distance is measured from the rear front of the device. of the device (standard setting). Distance unit setting Beep ON/OFF Switch between the following units: 2 sec 0.000m simultaneously 2 sec 0.00m 0.00ft 0‘00‘‘ 1/16 0.00in 0 1/16in Stabila LD 320...
  • Page 5: Measuring Functions

    8.532 es. Against dark surfaces the measuring time increases. Aim active laser at target. Permament measuring The last value mea- sured is displayed. 2 sec Stops permanent measur- ing. 8.532 Aim active laser at target. Stabila LD 320...
  • Page 6: Area

    Volume Aim laser at first Aim laser at sec- Aim laser at third target point. ond target point. target point. The result is shown in the main line and the measured value above. 78.694 Stabila LD 320...
  • Page 7: Pythagoras (2-Point)

    Aim laser at lower point. per point. tangular point. The result is shown in the main line and the measured distance above. Pressing the measuring key for 2 sec in the function activates automatically Minimum or Maxi- mum measurement. 8.294 Stabila LD 320...
  • Page 8: Minimum Tracking

    Min. ble for Py- Distance thagoras calculations. Current 2.332 Min. measured 2.332 2.847 Distance value Maximum Tracking Min/max measurement is also availa- Max. ble for Py- Distance thagoras calculations. Current 4.684 Max. measured 4.242 4.684 Distance value Stabila LD 320...
  • Page 9: Technical Data

    100 x 54 x 30 mm 3.94 x 2.13 x 1.18 in Weight (with batteries) 100 g / 3.21 oz Temperature range: - Storage -25 to 70 °C -13 to 158 °F - Operation 0 to 40 °C 32 to 104 °F Stabila LD 320...
  • Page 10: Message Codes

    Clear button and Warranty Responsibilities of the manufacturer observe the following instructions: of the original equipment: Cause Correction Stabila provides a two-year warranty for STABILA Messgeräte the Stabila LD 320. Calculation error Perform measurement Gustav Ullrich GmbH again.
  • Page 11: Permitted Use

    • Aiming directly in the sun humans. Do not use the product in explo- requirements of the relevant standards sion hazardous areas or in aggressive and regulations. environments. Yet, the possibility of causing interference in other devices cannot be totally excluded. Stabila LD 320...
  • Page 12: Fcc Statement (Applicable In U

    CAUTION receiver is connected. Looking into the laser beam may be • Consult the dealer or an experienced hazardous to the eyes. radio/TV technician for help. Subject to change (drawings, descriptions and technical data) without prior notice. Stabila LD 320...
  • Page 13: Ec Declaration Of Conformity

    EC Declaration of Conformity Stabila LD 320...

Table of Contents