0.5 bar (7 p.s.i.) Maximum supply pressure 10 bar (145 p.s.i.) Nominal commissioning times (minutes) full temperature ready Supreme 140 Supreme 155 Supreme 170 COMPONENT CHECKLIST Before commencing installation check that all the following components have been supplied with your Supreme heater.
1.0 IMPORTANT INSTALLATION POINTS 1.1 The Supreme stores and dispenses water at or close to boiling point at all times it is switched on. Due caution must be taken when choosing a location for the product to minimise misuse. Locate the unit over the draining board NOT over the sink or basin.
A drip tray is available as an accessory (Heatrae Sadia Code No. 95.970.123). The heater should be positioned at such a level that suitable tea, coffee, etc. making utensils can be placed under the outlet spout (approximately 250mm above the work surface is suggested).
Page 5
2.5 Mark the fixing positions and water, vent and electrical supply entry points. Drill and plug the fixing positions. Fix the mounting bracket to the wall using the two No.12 x 2” screws provided. 2.6 If rear entry services are to be used the necessary holes for these should be prepared prior to hanging the unit onto its bracket.
It is recommended that this is done automatically by incorporating a suitable timeswitch in the supply to the unit. The use of Heatrae Sadia accessory no. 95.970.124 is recommended. The timeswitch can then be set to switch the unit on for a suitable period to allow it to heat up before it is next to be used.
Page 8
6.0 COMMISSIONING 6.1 The electronic control system of the Supreme has a self commissioning and calibration function. Once the heater is installed and all services have been connected the unit should require no further adjustment before use. 6.2 Check that all electrical, water and vent pipe connections have been made and are secure.
Supreme Maintenance Plan Heatrae Sadia are pleased to offer a preventative maintenance program to ensure that your product will continue to operate to your satisfaction in even the most troublesome of water conditions.
8.0 FAULT FINDING SAFETY NOTE: DISCONNECT THE ELECTRICAL SUPPLY BEFORE REMOVING THE COVER AND CARRYING OUT ANY OF THE FOLLOWING ACTIONS. DO NOT BYPASS ANY SAFETY CONTROLS. SYMPTOM POSSIBLE CAUSE ACTION No indicator 1. If no water or heat - no 1.
Page 11
Unit left unused for several Empty and allow to refill water days. before use Any faults that cannot be identified using the Fault Finding chart, or in case of doubt, contact the Heatrae Sadia Service Department, telephone (08701) 600125, fax (08701) 600181.
DO NOT REPLACE WITH PARTS NOT RECOMMENDED BY HEATRAE SADIA - THIS WILL INVALIDATE YOUR GUARANTEE AND MAY RENDER THE INSTALLATION DANGEROUS. Element assembly 95 606 952...
Page 14
10.0 USER INSTRUCTIONS 10.1 Once installed the filling and heating cycles of the Supreme are completely automatic. 10.2 To dispense the water the tap handle should be pulled down and towards the user, a suitable container having been placed under the outlet spout.
Page 15
4. The unit has been used only for heating potable water. The unit is not guaranteed against damage by frost or due to the build up of scale. Please note that if Heatrae Sadia personnel or agents are requested to descale a unit, this work will be chargeable.
Page 16
780 South Street, Whiteinch, Glasgow G14 0SY Tel: 0141 4341530 Main No: 01603 420100 Main Fax: 01603 420218 Sales: 01603 420110 Service: 08701 600125 Service Fax: 08701 600181 Heatrae Sadia Heating Hurricane Way Norwich NR6 6EA www.heatraesadia.com 36 00 5826 Issue 4...
Need help?
Do you have a question about the SUPREME 140 and is the answer not in the manual?