RS-232 Command and Configuration
RS232 Serial Remote Control Command
Item
Description
Baud Rate
19200
Parity Bit
none
Data Bit
8
Stop Bit
1
Assign Port
COM1
Power On Command
Send String
BE, EF, 10, 05, 00, C6, FF, 11, 11, 01, 00, 01, 00
Response
06
Comment
Power Off Command
Send String
BE, EF, 03, 06, 00, DC, DB, 69, 00, 00, 00, 00, 00
Response
06
Source Command
Send String
BE, EF, 02, 06, 00, 57, D0, 2E, 00, 00, 00, 00, 00
Response
06
Comment
Auto-Sync Command
Send String
BE, EF, 02, 06, 00, 86, D1, 2F, 00, 00, 00, 00, 00
Response
06
Comment
Menu(for OSD) Command
Send String
BE, EF, 02, 06, 00, E9, D3, 30, 00, 00, 00, 00, 00
Response
06
Comment
Up (for OSD) Command
Send String
BE, EF, 02, 06, 00, 6D, D2, 34, 00, 00, 00, 00, 00
Response
06
Comment