Convergence Adjustment - Sony KV-XA34M66 Service Manual

Trinitron
Hide thumbs Also See for KV-XA34M66:
Table of Contents

Advertisement

4
BMC (Hexapole) Magnet.
If the red, green and blue dots are not balanced or aligned, then
use the BMC magnet to adjust in the manner described below.
R G
B
R
R
B
G
R
5
Y separation axis correction magnet adjustment.
1. Receive the cross-hatch signal and adjust [PICTURE] to [MIN]
and [BRIGHTNESS] to [STANDARD] .
2. Adjust the Y separation axis correction magnet on the neck
assembly so that the horizontal lines at the top and bottom of
the screen are straight.
(2) Dynamic Convergence Adjustment
Preparation:
Before starting this adjustment, adjust the horizontal static
convergence and the vertical static convergence
R B
G
B
R
G B
G
B
G
R
B
TLH
R B
YCH
Blue
Neck assy
Red
VM1 board
Note
1. The Red and Blue magnets should be equally far from the
horizontal center line.
2. Do not separate the Red and Blue magnets too far. (Less than
8 mm)
B
R
TLV
R
B
XCV
– 67 –
KV-XA34M66/XA34M86
RM-953
KV-XA34M80/XA34N90
RM-954
RM-914
Red
Neck assy
Blue
VM1 board