Download Print this page

Sony SNCA-ZX104 Installation Manual page 2

Hybrid camera receiver
Hide thumbs Also See for SNCA-ZX104:

Advertisement

A
B
SNCA-ZX104
SNCA-ZP104
C
IPELA HYBRID-compatible camera
Coaxial cable × 4
I/O port
connector
Coaxial cable × 4
To a
keyboard
Network cable
AC adaptor
(straight,
not supplied)
10BASE-T/
100BASE-TX
To an analog
To power
monitor
socket
Hub
Network
The section within the dotten line applies to
SNCA-ZX104 only.
D
IPELA HYBRID-compatible camera
(Serial PTZ-compatible)
Keyboard
Camera 1
SNCA-ZX104
(RS-485: On)
Camera 2
Network
SNCA-ZP104 or
SNCA-ZX104 (RS-485: Off )
Camera 3
SNCA-ZP104 or
SNCA-ZX104 (RS-485: Off )
Camera N
SNCA-ZP104 or
SNCA-ZX104 (RS-485: Off )
Camera N+1
SLOC (IP coaxial
transfer)
Camera 255
E
SNCA-ZX104
SNCA-ZP104
210 (8
/
)
3
8
Unit: mm (inches)
Location and Function of Parts
Front
 POWER indicator (green)
When the receiver receives power, an internal system check is performed.
The indicator lights up when the unit is operating normally.
 NETWORK indicator (green)
The indicator lights up or flashes in green when the unit is connected to the network.
The indicator remains off when the unit is not connected to the network.
 SLOC indicator (orange)
The indicator lights up in orange when an SLOC connection to a hybrid camera is
established.
The indicator flashes in orange when an SLOC transmission error is occurring.
Rear
 SLOC (IP coaxial transfer) port
Use this terminal to connect the unit to an IPELA HYBRID-compatible camera via a
coaxial cable.
 DC IN 12 V DC (power input) terminal
Connect to the supplied DC 12 V AC adapter.
 Video output terminal (BNC)
Outputs composite video signals.
 Reset switch
To reset the unit, press this switch. To restore the unit's factory default settings, press
this switch for more than 3 seconds.
To push the switch, use a pointed object.
 RS-485 selection switch (SNCA-ZX104 only)
Set this switch to ON to enable network functions; this unit's settings can then be
changed over the network that is connected via the LAN port. This unit's Serial PTZ
functions are also enabled; the unit can accept input from the keyboard connected to
this unit's I/O port.
Set this switch to OFF to disable network functions and block input from the I/O port.
 I/O (input/output) port (SNCA-ZX104 only)
This unit includes an RS-485 port. You can connect a keyboard that is compatible with
Pelco-D protocol control signals in order to control the unit.
Indication
Function
NC
G
RS-485 reference GND
+
RS-485 (+) input/output (GND level reference)
RS-485 (–) input/output (GND level reference)
 LAN (network) port (RJ-45)
Connect to a 10BASE-T or 100BASE-TX network using a network cable (UTP, category
5).
Caution
 For safety, do not connect the connector for peripheral device wiring that might
have excessive voltage to this port. Follow the instructions for this port.
 When you connect the LAN cable of the unit to peripheral device, use a shielded-
type cable to prevent malfunction due to radiation noise.
Connection
Connecting to the Network
Connect the unit via its LAN port using a network cable (not supplied).
Connecting to a Monitor
Connect a video output terminal of the unit to an analog monitor using a coaxial cable
(not supplied).
Connecting to an IPELA HYBRID-compatible Camera
Connect a SLOC port of the unit to an IPELA HYBRID-compatible camera's SLOC port
using a coaxial cable (not supplied).
The maximum coaxial cable length is RG-59 300 m.
Note
The high-frequency characteristics of coaxial cables may differ, even if the cables are of
the same classification. Use a high-quality, high-frequency coaxial cable with this unit.
For details on coaxial cables and cameras that can be connected to this unit, refer to the
instruction manual of the connecting SLOC device. For further details, please consult an
authorized Sony dealer.
Connecting to a Keyboard (SNCA-ZX104)
Using the supplied I/O port connector, connect a keyboard (not supplied) that
supports the Pelco-D protocol, and set the RS-485 selection switch to ON.
Set the RS-485 selection switch of SNCA-ZX104 units without connected keyboards to
OFF.
For details on settings related to the Serial PTZ function and settings related to connecting
the keyboard, refer to the SNCA-ZX104 User's Guide.
For details on camera settings related to Serial PTZ, refer to the camera's Instruction
Manual.
Connecting the Power Source
Connect to the supplied DC 12 V AC adapter.
Connecting multiple receivers and using the Serial PTZ
function
Using an SNCA-ZX104 as the first receiver, set its RS-485 switch to On, and then
connect the keyboard.
An SNCA-ZX104 with its rear RS-485 switch set to Off, or an SNCA-ZP104 can then be
connected and used.
For details on setting the receiver's Serial PTZ function, refer to the SNCA-ZX104 User's
Guide. For details on settings for the connected camera(s), refer to the connected
device's Instruction Manual.
For compatible IPELA HYBRID cameras, contact your authorized Sony dealer.
Specifications
Interface
SLOC input
BNC ×4, 75Ω termination
Analog video output
BNC ×4, composite 1.0 Vp-p, 75Ω termination
Hub
Network port
10BASE-T/100BASE-TX, auto negotiation (RJ-45)
I/O port (SNCA-ZX104 only)
Camera control interface: ×1 (RS-485)
Others
Power supply
DC 12V
Consumption current
0.7 A
Operating temperature
0 °C to 45 °C (32 °F to 113 °F)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Operating humidity
20% to 80% (no condensation)
Storage humidity
20% to 80% (no condensation)
210 × 44 × 250 mm (8
/
× 1
Dimensions 
3
8
(without the projecting parts)
Mass
Approximately 1.2 kg
Supplied accessories
CD-ROM (User's Guide and supplied programs) (1)
Installation Manual (this document) (1)
B&P Warranty Booklet (1)
AC adaptor (AC-NB12A) (1)
Power cord (1)
I/O port connector (SNCA-ZX104 only) (1)
Note
This package may contain additional installation
manuals and/or documentation.
AC adaptor (AC-NB12A)
Power supply
AC 100 to 240 V, 50/60 Hz
0.65 A to 0.35 A
Output
DC 12 V, 2.5 A
Operating temperature
0 °C to 45 °C (32 °F to 113 °F)
Operating humidity
20% to 80% (no condensation)
Storage temperature
–20 °C to +60 °C (–4 °F to +140 °F)
Storage humidity
20% to 80% (no condensation)
Dimensions
49.5 × 28 × 99.5 mm (2 × 1
the projecting parts)
Mass
Approximately 0.2 kg (7 oz)
Design and specifications are subject to change without notice.
Recommendation of Periodic Inspections
In case using this device over an extended period of time, please have it inspected
periodically for safe use.
It may appear flawless, but the components may have deteriorated over time, which
may cause a malfunction or accident.
For details, please consult the store of purchase or an authorized Sony dealer.
NOTICE TO USERS
© 2012 Sony Corporation. All rights reserved. This Installation Manual, in whole or in
part, may not be reproduced, translated or reduced to any machine readable form
without prior written approval from Sony Corporation.
SONY CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL,
THE UNIT OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY
DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY
PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE UNIT OR SUCH OTHER
INFORMATION. IN NO EVENT SHALL SONY CORPORATION BE LIABLE FOR ANY
INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, WHETHER BASED ON TORT,
CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THIS
MANUAL, THE UNIT OR OTHER INFORMATION CONTAINED HEREIN OR THE USE
THEREOF.
Sony Corporation reserves the right to make any modification to this manual or the
information contained herein at any time without notice.
 "IPELA",
and
Sony Corporation.
 Adobe and Adobe Reader are trademarks of Adobe Systems Incorporated in the
United States and/or other countries.
 sloc™ is a trademark owned by the Intersil Corporation family of companies.
All other company and product names are trademarks or registered trademarks of
the respective companies or their respective makers.
/
× 9
/
in) (w/h/d)
3
7
4
8
1
/
× 4 in) (w/h/d) (without
8
are trademarks of

Advertisement

loading

This manual is also suitable for:

Snca-zp104