1. 1. 1. INTRODUCTION
INTRODUCTION
INTRODUCTION
The instrument is a high performance, high accuracy, 3
high LCD multi-meter for measuring DC and AC voltage, DC and AC current,
Resistance and Capacitance, Frequency, temperature, duty circle, Transistor, Diode
and Continuity test. Design parameter: unit indication, data hold (HOLD), relatively
measuring (REL), AUTO/MANUAL range, auto off and buzzer sounds, etc.
The Dual-slop A/D converter
CMOS technology for auto-zero, polarity
selection and over-range indication. Full overload protection is provided. Because
of its outstanding features, it is most suitable for use on production lines or for lab,
R & D, maintenance and repair work.
2 2 2 .SPECIFICATIONS
.SPECIFICATIONS
.SPECIFICATIONS
2.1GENERAL
2.1
2.1
GENERAL SPECIFICATIONS
GENERAL
SPECIFICATIONS
SPECIFICATIONS
Display: 3 3/4digit LCD with a max readings of 3999
Measuring method: Dual-slop integrating A/D converter system.
Sampling rate: Approx. 3times/second.
Max. Common Mode Voltage: 500V DC/AC RMS.
Range select method: Automatic and Manual
Polarity: Automatic negative polarity indication.
Over range indication: Only the MSD " OL" display.
Low battery : The "
" displays.
Safety standards :
EMC/LVD. The meter is up to the standards of IEC1010
Pollution Degree 2, Over voltage categoryⅡor double insulationⅡ.
Operating environment: Temperature (0 ~ 40)℃, humidity<80%RH.
Storage environment: Temperature (-10~50)℃, humidity<80%RH.
Power: Double, standard 1.5 volt battery. AAA 7# battery.
Dimension: 190mm (H)×93.5mm (W) ×37mm (D).
Weight: Approx.420g(including battery).
2.2
ELECTRICAL
SPECIFICATIONS
2.2
2.2 ELECTRICAL
ELECTRICAL SPECIFICATIONS
SPECIFICATIONS
Accuracy is ±(percentage of reading + number of digit) at(23±5)℃,<75%RH.
DC
DC
DC Voltage
Voltage
Voltage
Range
Accuracy
400mV
4V
±(0.5%+4d)
40V
400V
±(1.0%+6d)
1000V
Input impedance: 400mV range: more than 40MΩ
Overload protection: 1000V DC or AC peak value
DC mV
DC
DC
mV
mV: : :
Range
Accuracy
400mV
±(0.5%+4d)
AC Voltage
AC
AC
Voltage
Voltage
Range
Accuracy
4V
40V
±(0.8%+10d)
400V
±(1.0%+10d)
750V
Input impedance: 400mV range: more than 40MΩ; other range: 10MΩ
Frequency response: 750V range : 40-100Hz
other range: 40-400Hz
Overload protection: 1000DC/750VAC RMS
Indication
: mean value response (rms of sine wave)
Resistance
Resistance
Resistance
Range
400Ω
4kΩ
40kΩ
400kΩ
3
/
digit, 42mm digit
4
4MΩ
40MΩ
Overload protection: 250V DC/AC peak value
Open circuit voltage: 400mV
Note: at 400Ωrange, should short the test leads and measure the resistance of the wire,
then, minus from measuring.
DC Current
DC
DC
Current
Current
Range
400uA
4000uA
40mA
400mA
10A
Overload protection: 0.5A/250V fuse, 10A/250V fuse.
Max measuring voltage: Full scale mA range: 1.2V; A range : 100 mV.
Max input current: 10A (max. up to 15 seconds).
AC
AC
AC mV
mV
mV
Range
400mV
AC
Current
AC
AC Current
Current
Range
400uA
4000uA
40mA
400mA
10A
Overload protection: 0.5A/250V fuse, 10A/250V fuse
Max measuring voltage: Full scale mA range: 1.2V
Resolution
Max input current: 10A (up to 15 seconds).
0.1mV
Frequency response: 10A range: 40-100Hz; other range: 40-400Hz
1mV
Capacitance
Capacitance
Capacitance
10mV
Range
100mV
4nF
1V
40nF
other range: 10MΩ
400nF
4uF
40uF
Resolution
200uF
0.1mV
Overload protection :250V DC/AC peak value
Resolution
Frequency
Frequency
Frequency
1mV
Range
10mV
100Hz
100mV
1000Hz
10kHz
1V
100kHz
1MHz
30MHz
Input sensitivity: 1.0V
Accuracy
Resolution
±(0.8%+5d)
0.1Ω
1Ω
10Ω
±(0.8%+4d)
100Ω
1kΩ
±(1.2%+10d)
10kΩ
Accuracy
Resolution
0.1uA
±(1.0%+10d)
1uA
±(1.2%+8d)
10uA
100uA
±(1.2%+10d)
10mA
Accuracy
Resolution
±(1.6%+8d)
0.1mV
Accuracy
Resolution
0.1uA
1uA
±(1.5%+10d)
10uA
100uA
±(2.0+15d)
10mA
A range: 100mV
Accuracy
Resolution
±(2.5%+20d)
1pF
10pF
100pF
±(3.5%+8d)
1nF
10nF
±(5.0%+10d)
100nF
Accuracy
Resolution
0.01Hz
0.1Hz
1Hz
±(0.5%+10d)
10Hz
100Hz
1kHz
Overload protection: 250V DC/AC peak value
Diode and
Diode
Diode
and continuity
and
continuity Test
continuity
Test
Test
Range
Description
Display read approx. forward
voltage of diode
Buzzer sounds if resistance
Between terminals V/ Ω and COM
is less than about70±30Ω.
Overload Protection : 250V DC/AC peak value
Warning: do not input voltage at the range for safety.
Transistor
Transistor
Transistor hFE
hFE
hFE Test
Test
Test
Range
Displaying value
hFE NPN or
0~1000
PNP
Temperature
Temperature
Temperature
Range
Displaying value
< < < 400℃ ±(1.0%+5d)
(-20-1000)℃
≥400℃ ±(1.5%+15d)
Thermocouple: K type
Warning: do not input voltage at the range for safety.
3. 3. 3. FRONT
FRONT PANEL
FRONT
PANEL DESCRIPTION
PANEL
DESCRIPTION
DESCRIPTION
1.LCD
2.Function key
2-1.HOLD Key
2-2.REL Key
2-3.Hz/DUTY Key
2-4 "select" key
2-5.RANGE Key
3.Rotary Switch
4.Voltage, Resistance, Frequency socket.
5.COM input jack terminal
6.Less than 400mA input jack terminal
7.10A input jack terminal
4.OPERATION
4.OPERATION
4.OPERATION
1. Check the 1.5-volt battery by setting the ROTARY Switch removes to OFF position.
If the battery is weak, a
sign will appear on the display. If this does not appear on
the display, proceed as below. See MAINTENANCE if the battery has to be replaced.
2. The mark, or sign next to the lead jacks, is for warning that the input voltage or
current should not exceed the indicated values.
This is to prevent from damaging the internal circuits.
3. The function switch should be set to the range that you want to test before operation.
4 4 4 .1 .1 .1 DC
DC Voltage
DC
Voltage measurement
Voltage
measurement
measurement
1) Insert the BLACK test lead to "COM" jack and RED test lead to the "V/Ω/Hz"
jack.
2) Set the FUNCTION switch to "
" range.
3) The default range is Auto range, and "AUTO" is displayed. Pressing RANGE key
switch to manual range, 400mV/4V/40V/400V/1000V can be selected.
4) Connect the test leads to the tested point, the voltage and polarity which connected
with the red lead will appear on LCD.
Note:
Note:
Note:
1) Manual range, if LCD display "OL", over range is being indicated and the
FUNCTION switch must be set to a higher range.
2) Do not measure over 1000V, or, the meter will be damaged.
3)Caution to avoid contact with high voltage circuits when measuring high voltage.
Test Condition
Forward
DC
Current
approx.0.5mA. Reversed
voltage approx. 1.5V.
Open
circuit
voltage:
0.5V
Test condition
Base Current approx.
15uA, Vce approx. 1.5V
Test condition
1℃
Need help?