General Specification
MD3CN12M
Type / Format
NTSC
2:1 Interlace,
Scanning Element
H15.734KHz / V :59.9Hz
Image Picture Element
1/3" Interline CCD
Effective Picture Element
510(H) x 492(V)
Resolution (TV lines)
330
Minimum Illumination
0.7 Lux @ F1.6
S/N Ratio
48dB
Back Light Compensation
Central Area for DC IRIS Lens
Exposure Control
DC Type Auto IRIS Control
Sync System
INT
Gamma Compensation
0.45
1.0Vpp, 75 Ω Unbalanced
Video Output
Automatic White Balance
White Balance
2500K – 9700K
Auto White Ballance Range
Power Range*
DC 12V ±10%
Power Consumption
1.6W (Max)
Operating Temperature
-10°C ~ +50°C
Storage Temperature
-20°C ~ +60°C
Lens Specification
Focal Length
4mm~9mm
F-No.
Iris Range
F1.6~F2.4
Minimum Object Distance
4mm (71.3x48.3 cm)
Diagonal
92.8º~39.4º
Field Of View
Horizontal
71.0º~31.6º
51.6º~23.6º
Vertical
Funtion Control
Electronic Shutter
BLC
ON/OFF
AGC-UP
ON/OFF
Low Light Chroma Suppression
Regulatory Compliance
Emissions
FCC part 15 Class B
CE: EN55011
ICES-003
EN55022
CISPR 11
CISPR22
ANSI C63.4
Immunity
CE: EN50130-4
FCC COMPLIANCE:
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the
FCC Rules. These limits are designed to provide reasonable protection against armful interference in a residential installation.
This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the
instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will
not occur in a particular installation.
If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced Radio/TV technician for help.
CISPR 22 WARNING:
This is a Class B product. In a domestic environment this product may cause radio interference in which case the user may be
required to take adequate measures.
POWER SUPPLY REQUIREMENTS:
For use with listed Audio/Video product and only connected to 15W or less power supply.
*Power supply should be a NEC Class 2 / LPS Supply.
EQUIPMENT MODIFICATION CAUTION:
Equipment changes or modifications not expressly approved by seller.
The party responsible for FCC compliance could void the user's authority to operate the equipment and could create a
hazardous condition.
This class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
Please visit our website for more information
www. deview.com
MD3 Series
Tamper Proof Internal Dome Camera
Quick Installation Guide
* US Patent Pening
MD3CP12M
MD3CN12H
PAL
NTSC
2:1 Interlace,
2:1 Interlace,
H15.625KHz / V :50Hz
H15.734KHz / V :59.9Hz
H15.625KHz / V :50Hz
1/3" Interline CCD
500(H) x 582(V)
768(H) x 494(V)
480
1.2 Lux @ F1.6
48dB
Central Area for DC IRIS Lens
DC Type Auto IRIS Control
INT
0.45
1.0Vpp, 75 Ω Unbalanced
Automatic White Balance
2500K – 9700K
DC 12V ±10%
1.8W (Max)
-10°C ~ +50°C
-20°C ~ +60°C
F1.6
9mm (28.3x20.8cm)
------
AUTO
RoHS
Connecting Video-Power Cables
MD3CP12H
Video Output
PAL
2:1 Interlace,
752(H) x 582(V)

Camera Adjustments

Function Control Dip Switches
Switch 1
Switch 2
(Normal Mode)
Hardware Kit Contents
• 1/2" Rubber Grommet
• 3/4" Rubber Grommet
• Screw Pack
• Torx Driver
• Optional Quick Install Adaptor
• Wire-ended Power Adaptor lead
Template
Surface mount (In a wall or ceiling)
Using Quick Install Adaptor:
Create an aperture in the mounting surface to a diameter of
V531-DF000-240
1.5" (38mm) as indicated by "T2".
Ver A.070615
The aperture is also avaliable for cable access (3/4", 19mm).
Using screws:
Create four holes at template positions 'T1', use the screws
and plugs provided in the screw kit where the mounting
surface is appropriate.
Side Knock-out
Side Knock-out
RoHS
Power Input
GND
12VDC
Red : +12VDC
Black:
0 VDC
Wire-ended Power Adaptor Lead
A1 : Focus Adjuster
A2 : Field of View Adjuster
A3 : Function Control Dip Switches
*A4 : AI Level Adjustment
A1
A3
A2
A4
*AI Level Adjustment is factory set.
Should not normally require adjustment
Back Light Compensation
OFF
ON
Auto Gain Control
OFF
ON
(Turbo Mode)
Cable access
When the cables are threaded through the mounting surface,
create an apture indicated "T2". It can be simply threaded for
use with the quick install adapter .
When mounting the dome on a surfce with the four T1 screws,
use one of the side knock-outs as indicated for cable entry
(see Installation Guide overleaf ).
T1
T2
T1
Cable Access
T1
Side Knock-out
T1
Side Knock-out

Advertisement

loading

Summary of Contents for DeView MD3CN12M

  • Page 1: Camera Adjustments

    Connecting Video-Power Cables General Specification MD3CN12M MD3CP12M MD3CN12H MD3CP12H Video Output Type / Format NTSC NTSC 2:1 Interlace, 2:1 Interlace, 2:1 Interlace, 2:1 Interlace, Power Input Scanning Element H15.734KHz / V :59.9Hz H15.625KHz / V :50Hz H15.734KHz / V :59.9Hz H15.625KHz / V :50Hz...
  • Page 2: Preparation Before Installation

    Quick Install Adaptor Locking Arms Use the quick install adaptor on a wall or ceiling application. Installation Preparation before installation Use the template (see overleaf) to mark-out and prepare the mounting area. In order to mount the base, first remove the camera module by gently pulling down on the tabs that hold the camera module in place (see image right) and remove camera assembly.

This manual is also suitable for:

Md3cp12mMd3cn12hMd3cp12h