10 Safety Discharge Valve and Condensate Connections
10.1 Safety Valve Discharge
A short discharge pipe with nut and washer are supplied in a
pack at the bottom of the boiler packaging. Connect the discharge
tube to the heating safety valve.This must be extended, using
not less than 15mm o.d. pipe, to discharge, in a visible position,
outside the building, facing downwards, preferably over a drain,
see diagram 10.1.
WARNING: it must not discharge above an entrance, window
or any type of public access area.
IMPORTANT NOTE: To facilitate servicing of the appliance,
the discharge pipe MUST ONLY be extended using compression
fittings.
The pipe must have a continuous fall and be routed to a position
so that any discharge of water, possibly boiling, or steam cannot
create any danger to persons, damage to property or external
electrical components and wiring. Tighten all pipe connection
joints.
10.2 Condensate Drain Connection
The condensate drain connection is beside the pump at the rear
of the boiler, see diagram 10.2. A condense adapter for
21.5mm plastic overflow pipe is supplied loose in the installation
pack and should be used to fit to the drain connection, if
required, to discharge condensate to a drain. The drain pipe
should have a fall of a least 2.5
Condensate should, if possible be discharged into the household
internal drainage system. If this is not practicable, discharge
can be allowed into the external household drains or a purpose
designed soak away.
It is recommended that any external condensate drain pipe is
insulated and also preferably of 32mm diameter, to prevent
freezing in adverse weather conditions.
The condensate is discharged periodically in 'slugs' by syphonic
action.
It is not necessary to provide air breaks or extra traps in the
discharge pipe as there is already a 75mm. high trap inside the
boiler. Fitting an extra trap may cause the boiler siphon to work
incorrectly.
Refer to BS5546 or BS6798 for advice on the disposal of boiler
condensate.
2000225242A
o
away from the boiler.
SAFETY VALVE
DISCHARGE
TUBING
NUT
(F28e SHOWN )
CONDENSATE
DRAIN
CAP
(F28e SHOWN )
32
DISCHARGE
PIPE
Diagram 10.1
CONDENSE
ADAPTER
CONENSATE
Diagram 10.2
DRAIN PIPE