Mitsubishi Electric MSH-GA50VB Service Manual page 18

Wireless type
Hide thumbs Also See for MSH-GA50VB:
Table of Contents

Advertisement

9-6. Test point diagram and voltage
MSH-GA50VB -
E1
Indoor electronic control P.C. board
Fuse (F11)
250V AC 3.15A
R132
Receiver P.C. board
MSH-GA60VB -
E1
Release of "Auto restart function"
Solder jumper wire to JR07.
(Refer to page 10.)
MSH-GA80VB -
E1
Indoor coil thermistor(RT12(main), RT13(sub))
18
Fan motor power supply
}
Power supply input
230V AC
}
+
Room temperature ther-
mistor(RT11)
Indoor coil
thermistor(RT12(main))
MSH-GA80VB
Indoor coil
thermistor(RT13(sub))
Emergency operation
switch
Timer short mode point
(JPS, JPG)
(Refer to page 9.)
+
12V DC
Room temperature thermistor (RT11)
5V DC

Advertisement