EFM Heating VT 700 E Installation Instructions Manual

For hot water heating systems

Advertisement

NOZZLE SIZE
MODEL
GPH + TYPE
______________________________________________________________________________________
1.00 - 80 H
____________________________________ _
0.85 - 80 H
____________________________________ _
VT 700 E
0.75 - 80 H
____________________________________ _
0.65 - 80 H
______________________________________________________________________________________
1.65 - 80 H
____________________________________ _
1.50 - 80 H
____________________________________ _
VT 1000 E
1.35 - 80 H
____________________________________ _
1.10 - 80 H

Installation Instructions

CAUTION:
1. Installer must be a trained, experienced serviceman.
2. Inspect the boiler, jacket and all components to be sure damage has not occurred in shipment. If
damage is evident you must file a claim with the freight carrier immediately.
3. Disconnect power supply before connecting wiring.
4. Refer to local installation codes for oil burning equipment, for recommended installation practice.
5. A complete heat loss calculation is necessary to choose the proper size unit to install. The boiler
should be sized to within 25% of the actual heat loss of the structure.
6. Conduct thorough checkout when installation is complete.
1) Place the boiler on a level non-combustible
floor, preferably raised and as close to the
chimney as possible. The following minimum
clearances must be adhered to during instal-
lation and maintained thereafter to properly
clean, inspect and service your boiler: sides
and back - 6"; front - 24" and vent connector
e
f
m
Sales Company
Emmaus, Pennsylvania

Specifications

HEATING
NET
CAPACITY
OUTPUT
BTUH
BTUH
116,000
100,000
100,000
86,000
88,000
77,000
77,000
67,000
193,000
166,000
174,000
151,000
159,500
137,000
131,500
113,000
Installation Instructions
Boiler Burner Unit
Model VT 700 E
Model VT 1000 E
(For Hot Water Heating Systems)
NET
BECKETT
OUTPUT
CAPACITY
BURNER
SQ. FT.
664
570
AFG76XN
510
444
1,107
1,006
AFG76YB
915
754
18". Reduced clearance installations must
follow NFPA-31 guidelines.
2) For location of piping refer to the installation
drawing in Figure 5 and 6. The circulator is
shipped loose. Wire the circulator as shown
on the wiring diagrams in this manual. The
WATER
SMOKE
CHIMNEY
OUTLET
GAL.
SIZE
9
6
19
7
SHIPPING
WEIGHT
SIZE
POUNDS
8X8X15
315
8X8X15
435

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VT 700 E and is the answer not in the manual?

Questions and answers

Summary of Contents for EFM Heating VT 700 E

  • Page 1: Installation Instructions

    Installation Instructions Boiler Burner Unit Model VT 700 E Model VT 1000 E (For Hot Water Heating Systems) Sales Company • • • Emmaus, Pennsylvania Specifications HEATING WATER SMOKE SHIPPING NOZZLE SIZE BECKETT CHIMNEY MODEL CAPACITY OUTPUT OUTPUT CAPACITY OUTLET...
  • Page 2 circulator may be located on the return line 5) Be certain the chimney is clean and free of as shown in the diagram or in the supply obstructions. Connect boiler flue outlet to piping if desired. The aquastat is wired at the chimney using galvanized smoke pipe.
  • Page 3 8) The boiler is shipped with a nozzle installed. 2) Boilers Less Tankless Coil. This boiler is Check the nozzle and change it if a different equipped with a combination aquastat con- trol which has high and low limits to be set firing rate is desired.
  • Page 4 shown in the burner manual provided along Servicing the Boiler/Burner Unit with this manual. Burner settings are listed 1) Burner Components: If replacement of burn- on the Service Man’s Label attached to the er parts is necessary, always use parts rec- boiler and on the Burner Unit specifications ommended by the manufacturer.
  • Page 5: Installation Dimensions

    INSTALLATION DIMENSIONS Figure 1 Note: The circulator may be located on the supply side piping if desired. WIRING DIAGRAM SINGLE ZONE Figure 2...
  • Page 6 WIRING DIAGRAM MULTI-ZONE WITH CIRCULATORS Figure 3 WIRING DIAGRAM MULTI-ZONE WITH ZONE VALVES Figure 4...
  • Page 7: Piping Diagrams

    PIPING DIAGRAMS SUPPLY TO HOT WATER OUTLET HEATING CIRCUITS DISHWASHER TEMPERING/ TEMPERED MAKE UP MIXING WATER VALVE WATER COLD WATER RETURN FROM SUPPLY TO COIL HEATING CIRCUITS TANKLESS WATER HEATER PIPING Figure 5 Note: the circulator may be located on the supply side piping if desired.
  • Page 8 SERVICEMAN LABELS • • • V T S E R I E S S/N: MODEL: VT 1000E Firing Rate G.P.H.: 1.10 1.35 1.65 Input BTU/HR: 154,000 189,000 231,000 DOE Cap. BTU/HR: 131,500 159,500 193,000 Net Rate BTU/HR: 113,000 137,000 166,000 Val.

This manual is also suitable for:

Vt 1000 e

Table of Contents