NOZZLE SIZE
MODEL
GPH + TYPE
______________________________________________________________________________________
1.00 - 80 H
____________________________________ _
0.85 - 80 H
____________________________________ _
VT 700 E
0.75 - 80 H
____________________________________ _
0.65 - 80 H
______________________________________________________________________________________
1.65 - 80 H
____________________________________ _
1.50 - 80 H
____________________________________ _
VT 1000 E
1.35 - 80 H
____________________________________ _
1.10 - 80 H
Installation Instructions
CAUTION:
1. Installer must be a trained, experienced serviceman.
2. Inspect the boiler, jacket and all components to be sure damage has not occurred in shipment. If
damage is evident you must file a claim with the freight carrier immediately.
3. Disconnect power supply before connecting wiring.
4. Refer to local installation codes for oil burning equipment, for recommended installation practice.
5. A complete heat loss calculation is necessary to choose the proper size unit to install. The boiler
should be sized to within 25% of the actual heat loss of the structure.
6. Conduct thorough checkout when installation is complete.
1) Place the boiler on a level non-combustible
floor, preferably raised and as close to the
chimney as possible. The following minimum
clearances must be adhered to during instal-
lation and maintained thereafter to properly
clean, inspect and service your boiler: sides
and back - 6"; front - 24" and vent connector
e
f
m
Sales Company
•
•
•
Emmaus, Pennsylvania
Specifications
HEATING
NET
CAPACITY
OUTPUT
BTUH
BTUH
116,000
100,000
100,000
86,000
88,000
77,000
77,000
67,000
193,000
166,000
174,000
151,000
159,500
137,000
131,500
113,000
Installation Instructions
Boiler Burner Unit
Model VT 700 E
Model VT 1000 E
(For Hot Water Heating Systems)
NET
BECKETT
OUTPUT
CAPACITY
BURNER
SQ. FT.
664
570
AFG76XN
510
444
1,107
1,006
AFG76YB
915
754
18". Reduced clearance installations must
follow NFPA-31 guidelines.
2) For location of piping refer to the installation
drawing in Figure 5 and 6. The circulator is
shipped loose. Wire the circulator as shown
on the wiring diagrams in this manual. The
WATER
SMOKE
CHIMNEY
OUTLET
GAL.
SIZE
9
6
19
7
SHIPPING
WEIGHT
SIZE
POUNDS
8X8X15
315
8X8X15
435