Operating The Lock; Bank User Group, Pin Positions, And User Codes; Bank User Group - Sargent and Greenleaf 6128 Programming And Operations Manual

Access management system a series
Table of Contents

Advertisement

5
Positions 00, 02, and 10 have default PIN Codes set at the factory:
PIN Position Description  
Programmer Code
Officer Code
User Code
Programmer Code (PC) can only set-up the operating parameters of the lock and download
the audit trail data . The Programmer Code cannot open the safe.
Bank User Group consists of up to 16 PIN Code positions; 2 Officers and 4 Administrators
who manage the lock programs and up to 10 Users who open and close the lock .
If the lock still has the original S&G factory default settings, you can open the lock by entering
a PIN position and PIN Code, which makes up an 8-digit User code, followed by the # key .
The lock is set to default to Multiple User mode which allows opening of the lock by entering
any valid code other than the Programmer Code . (See 3 .3 Setting Access Mode) .
(If lock does not open and beep patterns were heard after pressing the # key, reference
section 2 .3 .1 "Beep Patterns" to identify condition .)
We recommend that Users change their PIN Codes immediately after the PIN positions are
assigned (Section 3 .1) .
2.1 — Bank User Group, PIN Positions, and User Codes
2.1.1 — Bank User Group
Bank User Group is the factory default and is always active in each lock (unless disabled
under Service Mode operation) . The Bank User Group has an access hierarchy of Officers
(PIN positions 02 and 03), Administrators (PIN positions 04, 05, 06 and 07), and Users (PIN
positions 10 through 19) . See Tables A&B beginning on the next page for access privileges .
Bank User Group can be configured to operate in three different User access modes .
• Multiple User mode — any valid code for the lock (other than the Programmer Code) can be
used to open it .
• Manager / Employee mode — the Officers or Administrators enable/disable the access
privilege of individual User Codes . When in this mode the officer and Administrator Codes do not
open the lock .
• Dual Control mode— two independent User Codes are needed to open the lock . Officer and
Administrator Codes can be used to open the lock in this mode .
630-600
OPERATING THE LOCK
PIN Position 
Default PIN Code
00
02
10
MODEL 6128/6129 PROGRAMMING & OPERATIONS GUIDE
123456
020202
101010
.