LG MFL68026703 Owner's Manual page 10

Air-to-water heat pump
Table of Contents

Advertisement

Owner's Instruction
Weather-Dependent Operation
This mode is only applied to heating.
In order to save energy and to give highest comfort, setting temperature will follow outside
temperature. If outdoor temperature decreases, heating capacity for the house will increase
automatically in order to keep same room temperature. All parameters will be set by installer during
start-up procedure and will be adapted to the site characteristic.
Press OPER MODE button to select weather-dependent operation mode.
1
: Weather dependent
operation icon
2
Adjust the desired temperature level by pressing change TEMP buttons.
View Temperature
1
Press repeatedly VIEW TEMP
button
To select each temperature.
(Whenever press VIEW TEMP
button, the room temperature
will be displayed during 5
seconds.)
Temperature
Air
Water
10 Air-to-Water Heat Pump
Ex) Decreasing temperature profile by 3°C
Temperature Range
below 11
11 ~ 39
above 39
below 0
0 ~ 92
above 92
(based on room air temperature)
<Temperature adjust step (unit : °C)>
-5, -4, -3, -2, -1, 0, 1, 2, 3, 4, 5
Hot
Cold
: View room temperature
: View inlet temperature
: View outlet temperature
: View sanitary water temperature
(Only displayed when sanitary
water heating mode)
: View solar power temperature
(Only displayed when sanitary
water heating mode)
Display
actual temperature
actual temperature
(Unit:°C)
Lo
Hi
Lo
Hi

Advertisement