Reo-Pure EC9052545 Installation, Operation And Maintanance Manual page 16

4 stage reverse osmosis system with uv disinfection ec series

Advertisement

PROBLEM
-Feed water supply may be turned off.
-Water supply to the system may not be sufficient
and/or not meet operating specifications.
-Filter cartridges may be clogged.
-Tubing may be kinked or blocked.
-System just started up.
System makes
product water slow,
-Air pressure in the storage tank is too high.
or not at all.
-Product water check valve may be blocked.
-Membrane may be fouled or clogged.
-System over used.
-Storage tank shut-off valve may be closed.
-The water line from the tank to the faucet is too far
away, or too small in diameter.
-Low air pressure in storage tank.
Water flow from the
faucet is slow.
-Storage tank may not be holding air pressure.
-This is normal when system is operating, but should
Water is constantly
stop when not operating. The drain line flow
running to drain.
restrictor may not have been installed.
-Flow restrictor may be damaged/broken.
-Flow restrictor may be damaged/broken.
-Filtered water may have a different taste than what
you are used to.
-Carbon filter cartridge is depleted.
Water has unpleasant
-Fouled membrane element.
taste and/or odor.
-Contamination in storage tank and/or system.
-Membrane preservative and/or sanitizer may not be
flushed out of system.
-Low water usage.
-Storage tank and/or system may be contaminated.
-Product water and drain line may be reversed.
-The amount of chlorine in your water supply
exceeds maximum limits and has destroyed the
Bad taste and/or odor
membrane.
in the product water.
-The carbon filter is no longer removing chlorine
from the water supply.
-Filter cartridges and/or membrane element may
need replacing.
-Membrane may be fouled or damaged.
-Membrane element brine seal and/or o-rings may
be damaged or not positioned properly.
High TDS product
-The membrane element is new.
water.
Water has air bubbles
-Air in the system at start-up is common.
(cloudy).
Noise from the
-Air gap faucet.
faucet.
No water to drain.
-Drain line flow control plugged/blocked.
Leaks (dry the area
-Fittings may be loose or broken.
and isolate the
location of the leak).
-O-rings may be worn or twisted/kinked.
-Drain line tubing kinked or plugged.
-Drain line tubing kinked or plugged.
Water over flow at
Water over flow at
faucet air gap.
-Drain line tubing is not positioned correctly.
EC SYSTEM TROUBLESHOOTING GUIDE
POSSIBLE CAUSE
#EC9052545-9055045-9051004 -- Page 15
SOLUTION
-Check feed water line and incoming valves are open.
-Increase the water pressure by adding a booster pump.
Precondition the feed water to meet the System Specifications
(See Operating Manual).
-Replace filter cartridges.
-Inspect and remove restriction.
-It may take 2-3 hours to fill the storage tank. Low water
pressure and/or cold water temperature can reduce the
production rate.
-Back pressure from the storage tank will slow production.
Check that the air pressure in the tank is between 8-10 psi, when
the tank is empty.
-Remove and clean, or replace.
-Replace membrane element.
-Note the System's daily production rating. Low water pressure
and/or cold water temperature can reduce the production rate.
Consider a larger tank or system.
-Check that the tank shut-off valve is fully open.
-Keep lines direct and as short as possible. Increase tubing
diameter from tank to faucet.
-Add pressure to the storage tank. When the tank is empty, the
pressure should be 8-10 psi.
-The bladder inside of the storage tank may be damaged.
Replace the storage tank.
-Check that the drain line flow restrictor is installed in the drain
line connection. Also check that it has been installed correctly.
-Replace drain line flow restrictor.
-Replace drain line flow restrictor.
-This is normal
-Replace carbon filter cartridge(s).
-Replace membrane element.
-Use sanitizing procedures.
-Fill the storage tank a few times and flush to drain.
-Completely drain system and allow to refill.
-Sanitize system and tank, and replace filters and membrane.
-Check plumbing. See the flow diagram for assistance.
-If the water supply contains more the 2.0 ppm of chlorine,
additional filtering of the water supply to the system is needed.
-Replace the membrane element and filter cartridges.
-Replace if necessary.
-Replace membrane element.
-Remove membrane element and examine brine seal and o-
rings. Repair or replace.
-Do not drink the first water produced from a new membrane
element. Flush the first few tanks to drain prior to drinking.
Product water TDS may be higher until thoroughly rinsed.
-This will clear up after the system runs a few days.
-When the system is running, it is normal to hear noise from an
air gap faucet.
-Replace drain line flow restrictor.
-Remove fittings and check for damage. Replace or clean and re-
tape threads.
-Remove and check for damage. Replace if necessary.
-Inspect and eliminate restriction. Periodic inspection is
-Inspect and eliminate restriction. Periodic inspection is
recommended.
-Check for low spots and loops. Reposition if necessary.