Page 1
Logitek MON-10 Meter Monitor & Switcher Operation & Service Manual...
Page 2
All information contained herein is con- fidential. No portions of this manual may be reproduced by any means with- out written permission from Logitek Electronic Systems, Inc. COPYRIGHT 1990, LOGITEK ELECTRONIC SYSTEMS, INC.
50-60 hz (optional factory modification for 220-240 VAC) 1-4 Instrument Identification The MON-10 is identified by a model number and a three or four digit serial number. The model number ** MON-10 Instruction Manual ** and serial number appear on a label on the back of the unit near the power cord.
When feeding unbalanced equipment from the output of the MON-10, it is important that the “-” output termi- nal be left unconnected. Connecting this terminal to ground will not harm the equipment. However, it might cause undesired crosstalk.
3-4 VOLUME Control This control sets the level fed to the internal speaker, the external speaker and the headphone jack. It DOES NOT affect line output signal or the me- ter. ** MON-10 Instruction Manual ** Page 4...
18 volt outputs which feed the unit’s amplifier stages. 4-4 Switching and Amplification Circuitry Input signals to the MON-10 are selected by the in- put selector pushbuttons S1-S10 and fed directly to the LINE OUT terminals on the unit’s rear panel. The...
SECTION 6 — MANUFACTURERS LIST CODE ** MON-10 Instruction Manual ** MANUFACTURER Aavid Engineering Belden Wire and Cable Bourns, Inc. Bergquist Co. Centralab Electronics Div. Clarostat Mfg. Co., Inc. Chicago Miniature Lamp, Inc. Electronic Components Groupe Ecam Technology General Instruments/Quality Technologies Grayhill Inc.