Do you have a question about the Grey Power Gator Maxi 100 and is the answer not in the manual?
Questions and answers
Summary of Contents for Just Water Solutions Grey Power Gator Maxi 100
Page 1
Warranty Terms and Conditions Your Grey Water Gator Maxi 100 is covered by a 1 year return to base warranty If any part should fail other than the main pit it should be returned to the manufacturer for inspection. Warranty commences from date of purchase. Unit must be installed by a licensed plumber or qualified installer. Incorrect operation of unit is not covered by warranty. Labour and shipping for warranty claims are not covered in the terms of this document Installation and Operating Instructions Damages incurred to property or persons by incorrect operation or installation are not covered by this warranty. Please provide proof of purchase with all warranty claims. Grey Water Gator Maxi 100 Our total liability under any warranty is limited to replacing the defective or damaged goods or refunding the purchase price. We shall not be deemed liable for any loss beyond our control, or for any indirect or consequential loss of any kind ACN 124 112 705 ...
Page 2
Guidelines for the GREY WATER GATOR MAXI 100 Schematic Drawing Your Just Water Solutions Grey Water Gator Maxi 100™ is specifically designed for Grey Water Gator Maxi 100 Grey Water reuse from the laundry, shower and bath waste water. Your Grey Water Unit must be installed by a licensed plumber in accordance with regulations AS/NZ 3500.2.2.2003 Do not connect to a kitchen sink or Toilet as this is classed as Black Water and is not suitable for this unit or for reuse. Only connect to sub surface irrigation such as Grey Water Drip tube or sullage drain pipe. We recommend that you also check with your local Water Authority for approval of this type of Seasonal Use Grey Water Diversion device. It is mandatory that the power circuit to this unit is protected by a residual current circuit breaker and we highly recommend a surge protection device be fitted as well. Your Grey Water Unit is pre assembled. Please check the contents on delivery as in‐ transit damage may occur. INSTALLATION This unit must be installed by a licensed plumber and or service agent. Failure to comply will void the warranty 1. Your plumber / installer will install or locate your dedicated Grey Water Waste pipes. 2. Allow approx 350 mm from ground level to cut‐in point Inlet pipe. 3. If your pipe work is deeper than this, optional risers of 200mm are available. 4. The overflow pipe must be connected to a sewer discharge point such as a gully trap. 5. Excavate a suitable area approx 800mm deep 1000mm long and 600mm wide. Allow enough room for connection to pipe work, electrical cable and conduit. 6. Make sure the base is level using free flowing packing sand. Take time to level the unit and set the correct heights for the pipe work. Grey Water Gator Maxi 100 Pit 25mm Tank Inlet Fitting 7. ...
Page 3
14. Make sure the diversion valve is open allowing Grey Water to flow into the unit. 11. Do not pump the residual through the irrigation system. 15. Turning on a fixture inside the house that is connected to the grey water 12. Once everything is cleaned you can now reinstall the filters to the tank pipe‐work will allow Grey water to flow into the unit. taking care to fit them back the same as they were removed. 16. Turn on the power briefly and check the pump is operating correctly. The 13. You can fill the unit with clean water to check operation of floats and use Irrigation System is not connected at this stage, this will allow the unit to be that clean water to flush the irrigation system. flushed out. 14. Once you are happy the unit is operating correctly lift the handle on the 17. Installation of the irrigation system can now take place bypass valve to open the flow into the unit. 18. Your unit is now commissioned and ready for use. 15. Refit the top cover and lock the lid with your key. Additional notes 16. Your unit is now serviced and ready for operation. If a manifold is used on the irrigation system, at least one valve must be open at all times to prevent the pump operating at closed head, that is a no‐flow condition. At this time it is good practice to check over your irrigation system. Operation under these conditions will void the warranty. Turn on the drain valves at the end of your irrigation lines and remove any Minimum pipe size from the unit is 25mm. Using 25mm Lilac low density poly tube or sediment that may have accumulated in the pipes. Check for any leaks or 25mm PVC pipe is recommended. damage to the irrigation pipe work. Repair as necessary. Troubleshooting ...
Page 4
DISTRIBUTION OF DIVERTED GREY WATER Do not distribute grey water from your Grey Water Maxi unit via sprinklers or Current Government Regulations state that you must disperse untreated grey allow for airborne dispersion. water via a Subsurface irrigation system. Only irrigate when necessary and switch unit to divert when raining. You must use an approved irrigation system that is specifically designed for Grey Do not let diverted Greywater to run off to neighbouring properties. Water. Do not leave unit unattended when carrying out maintenance or when the Recommendations and Guidelines for irrigation system: cover is removed. The area required for your Irrigation system depends on the soil type. The chart below In case of extended periods of non operation it is advised to complete a shows the suggested spacing required between dripper lines for different soil types, in service and clean of the unit to avoid the possibility of drying out the sludge relation to the total area. Minimum pipe size from the unit is 25mm PVC or Low on the filters. Density poly tube. Make sure the maximum length of drip tube is 20 metres from the main line MAINTENANCE OF YOUR GREY WATER UNIT Soil Texture & Structure and Dripper line and row spacing Your Grey Water Gator Maxi has been designed for minimum maintenance. Due to the high flow capabilities of the 3 dimensional filters you should only need to Area required per person* in household (m2) clean your unit after approximately 40,000 + litres of flow through. 1‐2‐ 3‐ 4‐ 5‐ 6 Persons Depending of the number of occupants and the amount of water flowing through your unit the cleaning cycle will be between 180 – 360 days. Your filters still will keep working even up to maximum capacity. Soil Types ...