TABLE OF CONTENTS Chapter 1 BeneCheck Blood Glucose Monitoring System Introduction......................1-2 Contents of the Kit....................3 Labelling and Informations................4 System Components Meter..........................5-6 Test Strips........................7 Code Strip........................8 Chapter 2 Setting-up the Meter Installing/Replacing the Batteries............9-10 Set the Year/Month/Day/Hour............10-11 Set the Minute/Unit of Temperature............12 Coding the Meter..................13-15...
Chapter 7 Icon and Alert Tones............31 Intended Use : The BeneCheck Blood Glucose Monitoring System is designed to measure the blood Chapter 8 Error Message and Trouble Shooting......32-34 glucose levels in whole blood. The test strips are for testing outside the body ( in vitro diagnostic use ).
The BeneCheck Blood Glucose Monitoring System is calibrated by J&J DT60 1.2 Contents of the Kit Analyzer (Kodak EKTACHEM DT60 Analyzer) using venous plasma. The DT60 Please check the whole package for the BeneCheck Blood Glucose Monitoring Analyzer is calibrated by VITROS DT calibrators which were referenced to NIST System.
1.3 Labelling and Informations 1.4 System Components Meter ( Front Side ) Do not re-use Use by Test Port : Where you insert the test strip for test. Keep dry Read instructions Caution, consult Keep away from sunlight accompanying documents LCD Screen : Operation temperature for display of operating...
Fo r h o l d i n g t h e m e t e r together, do not open or the meter. disassemble the BeneCheck Sample Inlet : Blood Glucose meter. The inlet where the whole blood or control...
Test Port of the Instructions : meter. Hold the meter with one hand, slightly lift the back cover lid to open the back cover. BeneCheck Blood Glucose Meter Model : PD-A016 General Life Biotechnology Co., Ltd. No.53, Jung Jeng Rd., Shin Juang,...
Set the Year 1. Press the front button to advance one year until you get a correct year number. Please back the cover onto the meter. 2. After you set the desired year number, press the back setting button again then the meter enters into month setting. Set the Month 1.
The BeneCheck Blood Glucose Meter should be coded before testing with 1. Press and release the front button until the correct minute BeneCheck Glucose Test Strips for the first time, or every time a new box of appears. BeneCheck Glucose Test Strips is used. Each vial of test strips has an assigned 2.
2.4 Control Test Wait for the code number to appear on the screen. A control solution is used to check the performance of the BeneCheck Blood Glucose Monitoring System, including BeneCheck Blood Glucose Meter, BeneCheck Blood Glucose Test Strip, and the user’s operating skill. The system performs adequately if the control test result falls within the indicated control range listed on the test strip vial.
Page 11
● Any time the blood glucose test results are not consistent with how you feel, or any time you think your results are not accurate. ● Any time you drop or bump the meter. A blood drop symbol “ ” blinking on the screen means ●...
Page 12
● Close the test strip vial lid tightly after use. results. Compare the results to the control range listed on ● Do not use BeneCheck Blood Glucose Monitoring System to do any test until the test strip vial. you can get the control test result falls within the range listed on the test strip vial.
The meter will turn on automatically. Materials required to perform a blood glucose test include : ● BeneCheck Blood Glucose Meter ● BeneCheck Blood Glucose Test Strip ● Lancing Device / Lancet After “ CH ” and “...
If turned off, remove and re-insert the test strip to do the test again. Insert the BeneCheck Blood Glucose Test Strip and take a ● Test strips cannot be reused. If a used test strip is inserted, a warning blood sample according to the instructions for lancing device message “...
Note : Note : ● Please check your system performance regularly or when you suspect your test ● Please complete the test procedures within 3 minutes or the meter will result is inaccurate. automatically turn off. ● Dropping, bumping or other violent impact may damage the meter or cause ●...
6. To turn the meter off, press the “Front Button” for over 3 seconds and the meter will make a long “beep” sound. The meter will also automaticallyshut down The BeneCheck Meter automatically stores up to 180 records, both blood glucose after 3 minutes.
Chapter 5 How to Set the Glucose Measurement Units 4. Press the setting button once will shift to temperature setting. Press “Setting Button” again will finish the setting and turns off automatically. Directions : 1. Make sure that no test strip is inserted in the meter. Note : 2.
Chapter 6 Storage and Handling of Meter and Strips Chapter 7 Icon and Alert Tones Due to sensitive to heat and humidity, the performance of test strips may be 7.1 lcon on the Screen Memory Number Icon Code Number Icon affected by improper storage and handling.
Chapter 8 Error Message and Trouble Shooting Message Cause Solution U s a g e o f t h e c o d e s t r i p Check that the code number on the Message Cause Solution was inserted improperly, meter display matches the code There may be a problem Repeat the test with a new code...
Chapter 9 Specifications Message Cause Solution System Accuracy : ± 20% at glucose level > 75 mg/dL 1.Blood glucose level is 1. Review the instructions and try Test Sample : Capillary whole blood higher than 600 mg/dL. again with a new test strip. Measuring Time : Less than 10 seconds 2 .Test strip has problem.
Hct above 55% may cause reduced glucose results versus a whole blood reference. 3. BeneCheck Blood Glucose Test Strip is for single use only, please do not reuse the test strip. 4. Handle the strip with clean and dry hands; lancing site for the test should be cleaned and dried thoroughly.
Need help?
Do you have a question about the GLU and is the answer not in the manual?