DIS Central Unit CU 6010 User Manual

DIS Central Unit CU 6010 User Manual

Central unit for series dcs 6000 voting units, conference units, interpreter units, ambient noise microphone, channels selectors and audio output units
Table of Contents

Advertisement

DCS 6000
User Manual
CU 6005/6010/6011 Central Unit
Central Unit for series DCS 6000 Voting Units, Conference
Units, Interpreter Units, Ambient Noise Microphone, Channels
Selectors and Audio Output Units
Danish Interpretation Systems
Digital Conference System
DIS

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Central Unit CU 6010 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for DIS Central Unit CU 6010

  • Page 1 DCS 6000 User Manual CU 6005/6010/6011 Central Unit Central Unit for series DCS 6000 Voting Units, Conference Units, Interpreter Units, Ambient Noise Microphone, Channels Selectors and Audio Output Units Danish Interpretation Systems Digital Conference System...
  • Page 2 Danish Interpretation Systems User Manual Copyright © 2007 DIS CU6005 6010 6011 REV V.DOC 16-07-2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.
  • Page 3: Table Of Contents

    Danish Interpretation Systems List of Contents List of Contents... 3 Important ... 5 Compliancy... 5 Important safety instructions... 5 Labels ... 5 Installation precautions ... 5 Cleaning & Repacking... 6 Warranty ... 6 Description of the DCS 6000 system ... 7 Features...
  • Page 4 Danish Interpretation Systems Microphone conference system with 3+1 ch. interpretation & IR, CU 6005... 32 Microphone conference system with 15+1 ch. interpretation & IR, CU 6010... 32 Various configurations with RP 6004 Repeater and PS 6000 Power Supply ... 33 Small system with SW 6000 Conference Management Software...
  • Page 5: Important

    Danish Interpretation Systems Important Compliancy The equipment has been tested and found to comply with the limits of the following standards for digital devices: EN55103-1 (Emission) EN55103-2 (Immunity) EN60065 safety UL6500 safety FCC rules part 15, class A (Emission) The device complies with part 15 of the FCC rules. Operation is subject to the following conditions: (1) The device may not cause harmful interference, and (2) the device must accept any interference...
  • Page 6: Cleaning & Repacking

    Danish Interpretation Systems To avoid moisture condensations do not install the unit where the temperature may rise rapidly. When installing the unit inside a 19” rack, observe that the rack is properly ventilated. The maximum allowed temperature inside the rack is 40 C. Cleaning &...
  • Page 7: Description Of The Dcs 6000 System

    Danish Interpretation Systems Description of the DCS 6000 system Features The DCS 6000 system has the following main features: Fully digital Excellent sound quality “State of the Art” fully digital integrated interpretation, discussion and voting system offering interpretation, language distribution, conference microphone and voting facilities with attendance check with Chip Card ™.
  • Page 8: System Components

    Danish Interpretation Systems System components The CU 6005/6010/6011 Central Unit supports all available units in the DCS 6000 series: Central equipment etc. EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004 Repeater for four chains JB 6002...
  • Page 9: Operating Instructions

    Danish Interpretation Systems Operating instructions CU 6010 Central Unit General description The CU 6010 Central Unit for the DCS 6000 is the heart of the system. One CU 6010 is needed in each DCS 6000 system. The CU 6010 consist of four main parts: Main processor board with Power PC and DSP DCS-LAN Network Control Card with 4...
  • Page 10: User Controls, Indications & Connectors

    Danish Interpretation Systems User Controls, indications & connectors Front plate layout The front plate layout of the CU 6010 Central Unit consists of a large illuminated LCD display and 8 buttons for setting up/controlling the system: Details of display Front plate controls The CU 6010 Central unit features the following controls and display: Power switch...
  • Page 11 Danish Interpretation Systems Buttons The buttons below and to the left of the display are used when stepping through the different menus and for setting up the system: Four select buttons Four buttons placed on the left-hand side of the display.
  • Page 12: Back Panel Layout

    Danish Interpretation Systems Back Panel Layout Back Panel Connectors Mains Power connector Connection for mains power. See specs. Analog Audio Line input XLR Input connector. For connection of external Line input signal i.e. the Floor (Speaker) signal from another Conference Microphone System or audio mixers.
  • Page 13: Audio Control

    Danish Interpretation Systems A selection is made in the Main menu by scrolling through the menu items with the Up/Down buttons, and pressing the Select button associated with the desired menu item. When scrolling through the menu items, the Main menu wraps around the list of menu items, i.e.
  • Page 14 Danish Interpretation Systems Delegate setup “Delegate setup” menu following entries: Max Speakers Max. Requests Operation Mode Voice Detection Auto Off Setup Max Speakers This menu point has two settings: Max. Total Speakers Max. Delegate Speakers Values: {1, 2, 3, 4, 5, 6, 7, 8} The number of ‘Total Speakers’...
  • Page 15 Danish Interpretation Systems More delegates will be put in the request queue when they press their ON/OFF buttons, until the maximum of requests is reached. Their green ‘Request’ lamps will light up steadily. When one of the turned ON microphone units is switched off, the first delegate unit in the queue is automatically switched ON, and the next delegate unit in the queue will...
  • Page 16 Danish Interpretation Systems This setting is used to set the time from the delegate stops talking until the microphone turns off. The default value is 4 sec. Auto Off Setup This menu point has two settings: Auto Off Auto Off time Those settings determine the behaviour of the Auto Off facility for the conference units.
  • Page 17 Danish Interpretation Systems Complete Lock With this setting an interpreter cannot switch on his microphone to any occupied interpreter channel. This is the default setting. No Lock With this setting an interpreter turning on his microphone to any occupied interpreter channel, will turn of the interpreter occupying the channel.
  • Page 18: Security Setup

    Danish Interpretation Systems The Chain info menu displays information to the user about units connected to the CU. The information is divided into Chain A, Chain B and total. Found units are connected units, where the communication is maintained, and expected units comprises all units, which are defined in the ‘Configuration’.
  • Page 19 Danish Interpretation Systems The load is aborted with the Menu button and accepted with the Enter button. In both cases, the menu system returns to the Main menu. Save configuration If the “Save configuration” item is chosen this confirmation display is shown: This will overwrite the configuration in flash.
  • Page 20: Normal Operation

    Danish Interpretation Systems The user returns to the main menu by pressing either the Menu button or the Enter button. Normal Operation Powering up Switch on power at the CU 6010. After powering up, the display on the CU 6010 is showing the Start-up screen: Initializing Please Wait...
  • Page 21: Cu 6011 Central Unit

    Danish Interpretation Systems The LinelnLevel Adj has to be set as high as possible for maintaining the best S/N ration, but not too high to avoid clipping, whereas the LineIn- Units AO/IS CS/IS/DM CU 6011 Central Unit General description The functionality of CU 6011 is identical to the CU 6010 Central Unit.
  • Page 22: Cu 6005 Central Unit

    Danish Interpretation Systems CU 6005 Central Unit General description The functionality of CU 6005 is basically identical to the CU 6010 Central Unit; however the main parts are slightly different: Main processor board with Power PC and DSP DCS-LAN Network Control Card with 2 individual DCS-LAN outputs (instead of 4) One Power supply (instead of 4) LCD display and buttons for system settings...
  • Page 23: User Controls, Indications & Connectors

    Danish Interpretation Systems User Controls, indications & connectors Front plate layout Identical to the CU 6010 Central Unit. Front plate controls Identical to the CU 6010 Central Unit. Back Panel Layout Back Panel Connectors As the CU 6010 Central Unit with the following differences: Chain A1 &...
  • Page 24: System Setup

    Danish Interpretation Systems System Setup General guidelines Connect the CU 6005/6010/6011 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. The operation of the DCS 6000 units is found in the User Manual for the specific units. Please observe the following guidelines: Maximum cable length in one chain is 200 (before...
  • Page 25: Cm/Dm 60X0P Chairman/Delegate Units – Cu 6005

    Danish Interpretation Systems Maximum number of units to be connected The following table shows the maximum number of units, which can be connected to each of the four outputs on a CU 6010/6011 (A1, A2, B1 or B2) CM/DM 60x0P Chairman/Delegate Units – CU 6010/6011 Length of Feeding Cable Type CAT5 AWG24 10 m...
  • Page 26: Cm/Dm 6060F/6510F Chairman/Delegate Units - Cu 6010/6011

    Danish Interpretation Systems Length of Feeding Cable, Type CAT5 AWG24 10 m 30 m 50 m 100 m 150 m CM/DM 6060F/6510F Chairman/Delegate Units – CU 6010/6011 The following table shows the maximum number of units, which can be connected to each of the four outputs on a CU 6010/6011 (A1, A2, B1 or B2)
  • Page 27: Dc 6990P Conference Units - Cu 6010/6011

    Danish Interpretation Systems DC 6990P Conference Units – CU 6010/6011 The following table shows the maximum number of units, which can be connected to each of the four outputs on a CU 6010/6011 (A1, A2, B1 or B2) Length of Feeding Cable Type CAT5 AWG24 10 m 30 m...
  • Page 28: Mu 6040C/D And Mu 6042D Without Connected Loudspeaker - Cu 6010/6011

    Danish Interpretation Systems MU 6040C/D and MU 6042D without connected loudspeaker – CU 6010/6011 This table shows the maximum number of MU 6040 Microphone Units, which can be connected to each of the four outputs (A1, A2, B1 or B2) 6010/6011 Central Unit or on each output on an EX 6010 Extension Unit or on the output of a PS 6000.
  • Page 29: Is 6132P W/Jb 6004 And Ls 6032 - Cu 6010/6011

    Danish Interpretation Systems IS 6132P w/JB 6004 and LS 6032 – CU 6010/6011 Length of Feeding Cable, Type CAT5 AWG24 10 m 10 m 30 m 30 m 50 m 50 m 100 m 100 m 150 m 150 m CS 6032F Channel Selector w/back light on –...
  • Page 30: Typical Schematics

    Danish Interpretation Systems User Manual Typical schematics The following schematics are showing various configurations: Small conference microphone system with CU 6005 Small conference microphone system with CU 6010 Manual 01 18 04438...
  • Page 31: Large Size Conference Microphone System

    Danish Interpretation Systems User Manual Large size conference microphone system Microphone conference system with interpretation CU 6010 Manual 01 18 04438...
  • Page 32: Microphone Conference System With 15+1 Ch. Interpretation & Ir, Cu 6010

    Danish Interpretation Systems User Manual Microphone conference system with 3+1 ch. interpretation & IR, CU 6005 Microphone conference system with 15+1 ch. interpretation & IR, CU 6010 Manual 01 18 04438...
  • Page 33: Various Configurations With Rp 6004 Repeater And Ps 6000 Power Supply

    Danish Interpretation Systems User Manual Various configurations with RP 6004 Repeater and PS 6000 Power Supply Manual 01 18 04438...
  • Page 34: Small System With Sw 6000 Conference Management Software

    Danish Interpretation Systems User Manual Small system with SW 6000 Conference Management Software Manual 01 18 04438...
  • Page 35: Large System With Sw 6000 Conference Management Software

    Danish Interpretation Systems User Manual Large system with SW 6000 Conference Management Software Manual 01 18 04438...
  • Page 36: Appendix

    Danish Interpretation Systems Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. EIA 568-B wiring shall be used. It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.
  • Page 37: Accessories (Not Supplied)

    Danish Interpretation Systems Important Please observe that either the RS232 Serial Connection or the RS422 Serial Connection can be used. It is not possible to use both at the same time. Analog Audio, Line output (XLR3 male) Signal Ground DIS type #2914 In phase signal or 2 x 0.25 mm shielded.
  • Page 38: Technical Specifications

    Danish Interpretation Systems Technical specifications Digital Section Sound quality ...24 bit audio @ 32 kHz sampling frequency Analogue Section Floor output signal type ... electronically balanced Nominal output level ... -8 dBm at nominal input Max. output level...3.5V RMS +13 dBm Line input signal type ...
  • Page 39 Danish Interpretation Systems User Manual Manual 01 18 04438...

Table of Contents

Save PDF