  • Page 1 DCS 6000 User Manual Digital Conference System PS 6000 Power Supply Danish Interpretation Systems...
  • Page 2 Danish Interpretation Systems User Manual Copyright © 2007 DIS PS6000 REV B.DOC 21-05-2007 No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.
  • Page 3: Table Of Contents

    Central equipment etc... 6 Interpreter equipment ... 6 Voting equipment... 6 Conference equipment and channel selectors . 6 Operating instructions ... 7 PS 6000 Power Supply ... 7 General description ... 7 Features ... 7 Connectors... 7 Copyright © 2007 DIS No part of this publication may be reproduced or utilised in any form or by any means without permission in writing from the publisher.
  • Page 4: Important

    Safety Check that the voltage of your local power supply is within the operating voltage of the unit (100-240V AC). If a voltage conversion is required, consult your DIS dealer or qualified personnel.
  • Page 5: Description Of The Dcs 6000 System

    50 units on 2 chains or by the CU 6010 Central Unit, which drives up to app. 200 units on 4 chains. EX 6010 Extension Units or PS 6000 Power Supplies available if more units are required A total of 4000 units (delegate and/or interpreter units) can be connected to the system.
  • Page 6: System Components

    Danish Interpretation Systems System components The CU 6005/6010 Central Unit supports all available units in the DCS 6000 series: Central equipment etc. EX 6010 Extension Unit PS 6000 Power Supply AO 6004 Audio Output box AO 6008 Audio Output box RP 6004...
  • Page 7: Operating Instructions

    One connector for connection previous unit (i.e. CU 6005/6010. System design There are no settings to be done on the PS 6000 Power Supply. However it is important to observe, that the unit is only adding power to one of the chains on the CU 6005/6010 Central Unit.
  • Page 8: Use Of Ps 6000

    Danish Interpretation Systems Use of PS 6000 The PS 6000 can be inserted at any point in a DCS 6000 chain, where extra power is needed. The PS 6000 is used, when extra power is needed typically, where long feeding cables are needed.
  • Page 9: System Setup

    Danish Interpretation Systems System Setup General guidelines Connect the PS 6000 to the various DCS 6000 units using Cat5 or Cat5e FTP or STP screened cables. Please observe the following guidelines: Maximum cable length in one chain is 200 without repeater.
  • Page 10: Max. Number Of Units To Be Connected

    50 m 100 m 150 m CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply. Length of inter connecting Cable, Type CAT5 AWG24 6002. Maximum 5 m cable from JB 6002 to CM/DM 60x0 and max.
  • Page 11: Cm/Dm 6060F/6510F Chairman/Delegate Units

    50 m 100 m 150 m CU 6010 Central Unit or to each output on an EX 6010 Extension Unit or to the output of a PS 6000 Power Supply. Length of inter connecting Total cable length Cable, Type CAT5 AWG24...
  • Page 12: Mu 6040 C/D Without Connected Loudspeaker

    Danish Interpretation Systems MU 6040 C/D without connected loudspeaker This table shows the maximum number of MU 6040 Microphone Units, which can be connected. The numbers are with no audio in loudspeaker (no Length of Feeding Cable, Type CAT5 AWG24 10 m 30 m 50 m...
  • Page 13: Is 6132P W/Jb 6004 And Ls 6032

    Danish Interpretation Systems IS 6132P w/JB 6004 and LS 6032 Length of Feeding Cable, Type CAT5 AWG24 10 m 10 m 30 m 30 m 50 m 50 m 100 m 100 m 150 m 150 m CS 6032F Channel Selector w/back light on Length of Feeding Cable Type CAT5 AWG24 30 m...
  • Page 14: Appendix

    Danish Interpretation Systems Appendix Technical appendix Cabling CAT5 The DCS 6000 system uses CAT5, CAT5e or CAT6 FTP or STP cables with screened RJ45 connectors. EIA 568-B wiring shall be used. It is important to use only FTP or STP (screened) cables and screened RJ45 connectors and not UTP cable, which is unscreened.