  • Page 2 PRO S3 Graphics Items including the Software and any related documentation that you may have. Copyright 2014. ViewZ USA. All rights reserved NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
  • Page 3: Table Of Contents

    CHAPTER5 SERVER FEATURE SETTING ................. 25 5.1 SERVER CONFIGURATION ....................25 5.2 LAUNCH THE SERVER ......................35 CHAPTER6 MASTER FEATURE GUIDE ..................36 6.1 LOG IN ............................. 36 6.2 MODEL ............................ 48 6.3 PLAN ............................52 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page3...
  • Page 4 CHAPTER7 RS232TOOLS ......................60 7.1 SLAVE RS232 SETTING ......................60 7.2 MASTER RS232 SETTING ...................... 62 7.3 USING RS232T ......................... 63 CHAPTER8 SMARTTRANSMITTER ................... 65 8.1 SMARTTRANSMITTER INSTALLATION ................65 8.2 RUN SMARTTRANSMITTER ....................68 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page4...
  • Page 5: Chapter1 Introduction

    Windows 7 or new Table1-1 1.4 Software requirements  User needs to install ViewZ embedded or PRO S3 Graphics VideoWall driver on Slave machine. Before installing the PRO S3 MaxWall, please install the following software for playing media files: ...
  • Page 6: User Guide Overview

    S3 MaxWall‟s capabilities. [Quick start]. • Component Reference Section: describes all windows, menus, commands and other functions. Refer to this section to learn more about specific functions in PRO S3 MaxWall. [Components] PRO S3 Graphics MaxWall User Guide 7/7/2014 Page6...
  • Page 7: Chapter2 Installation

    RS232line Source Master Server Matrix Output Slave Control line Data line 2.1 Slave Installation 1. Run Slavesetup.msi on Machine1 to start Slave installation. 2. Click the Next button in the Welcome page. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page7...
  • Page 8 Figure 2.1-1 3. In the End-User License Agreement page, check “I accept the terms in the License Agreement” and click the Next button. Figure 2.1-2 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page8...
  • Page 9 4. Setup type: Choose Typical. Figure 2.1-3 5. Click the Install button to begin the installation. Figure 2.1-4 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page9...
  • Page 10: Server Installation

    After installation, there will be two new icons on the desktop. Slave configuration is used to change Slave configuration, Slave is used to start Slave. 2.2 Server Installation 1. Run serversetup.msi on Machine2 to start Slave installation. 2. Click the Next button in the Welcome page. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page10...
  • Page 11 3. In the End-User License Agreement page, check “I accept the terms in the License Agreement” and click the Next button. Figure 2-2-2 4. Click the Next button to continue. Figure 2-2-3 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page11...
  • Page 12 5. Setup type: Choose Typical. Figure 2-2-4 5. Click the Finish button to exit. Figure 2.2-5 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page12...
  • Page 13: Master Installation

    2. Click the Next button in the Welcome page. Figure 2.3-1 3. In the End-User License Agreement page, check „I accept the terms in the License Agreement’; click the Next button. Figure 2.3-2 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page13...
  • Page 14 4. Setup type: Click Typical. Figure 2.3-3 5. Click the Install button to begin the installation. Figure 2.3-4 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page14...
  • Page 15: Patch Installation

    6. Click the Finish button to exit the Setup Wizard and complete the installation. Figure 2.3-5 2.4 Patch Installation Check whether patch is in package, patch package helps user to update the SW Version without uninstalling and reinstalling. Figure 2.4-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page15...
  • Page 16: Chapter3 Quick Reference

    7. In Mode page, user can set XRGB, YUY2 color setting. Figure 3.1-1 3.2 Launch Slave Sentinel HASP Driver/License Key Plug the USB license key into Slave machine before running the Slave. Figure 3.2-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page16...
  • Page 17: Server Configuration

    5. In Source Group page, user can create and edit Source Group. 6. In Mode page, user can choose Slave running mode on Slave machine. 7. In Import/Export page, user can import or export Slave and Server setting database for use. PRO S3 Graphics MaxWall User Guide 7/7/2014...
  • Page 18: Launch Server

    Double-Click Master icon on desktop, input password, address, port, and click the OK button to log in Master. Note: The default settings are as follows: Password: admin Address: Slave server Computer IP Port: 2020 Figure 3.5-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page18...
  • Page 19: Create A New Model

    3. Click “Send changes to Slave in realtime” button, you can edit the model that is currently running. 4. Click “Control Server Remotely”, you can remotely control Slave-side by using a mouse & key board. Click “Esc” to exit. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page19...
  • Page 20: Chapter4 Slave Feature Settings

    User can customize the port, the modified port will be saved and kept for future use. 4.1.2 Change Passwords In Network page, set Slave passwords. Default Password: Admin. Note: keep passwords in Slave-side. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page20...
  • Page 21 User can set it as sharing to Master account, so that master account can perform media upload accordingly. Media page provides a background image setting, this background should be a picture or clip. Enable this function and the background will be stored there. Figure 4.1-3 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page21...
  • Page 22 4.1.5 Sensors User can set hardware range‟s warning value for slave machine. If hardware range‟s warning value exceeds the limit during running the Slave machine, PRO MaxWall will warn Slave and Master machine. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page22...
  • Page 23 Choose the color setting in Mode page, YUY2 is set as default value. Decode: If a HW decode card is inserted, enable EVR can enhance your CPU performance. Debug: For debug purpose only. Figure 4.1-7 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page23...
  • Page 24: Launch Slave

    Show PRO S3 MaxWall version and copyright Note:When pressing Esc to exit from Slave player, Slave icon still appears in the notification area, user needs to launch Slave again to play media files. PRO S3 Graphics MaxWall User Guide 7/7/2014...
  • Page 25: Chapter5 Server Feature Setting

    After installing the Server on Machine2, Server and ServerConfig icon will be shown on desktop. Double-click ServerConfig icon on desktop to start Server Config. Slave Port Settings User can change Master and Server communication Port in this page. Default Port: 2020. Figure 5.1-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page25...
  • Page 26 Change Password User can change Server password in this page, the default password is: Admin. Figure 5.1-2 Add Slave User can add one or more Slaves to Server in this page, Password: Admin (user can change this password in SlaveConfig) Address: Slave machine IP address Port: 6028 (user can change this password in SlaveConfig) Click Add Slave button to add Slave, use can add one or more Slaves.
  • Page 27 1. Select Use Matrix, select Matrix type and add it into Server. 2. Edit Matrix name. 3. Input Matrix Input Size, output Size and Com. 4. Click Auto Config, Server will automatically configure the Capture Source and Output Num. Figure 5.1-4 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page27...
  • Page 28 Source Group Grouping and editing inputs Figure 5.1-5 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page28...
  • Page 29 Click ‘Create’ button to make a new group name and write down the descriptions if needed. Figure 5.1-6...
  • Page 30 Select sources from the list and import them to right side, edit setting for each source such as: Pixels, positions, cut edges. Figure 5.1-7...
  • Page 31 Figure 5.1-8 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page31...
  • Page 32 Super large video grouping If customer needs to playback super resolutions video, simply split the video to several videos, group them by position and slave can combine them to one. This split and grouping will not sacrifice video quality, the frame timing difference between grouping videos will be less than 16ms.
  • Page 33 Full Screen: Content running as Full Screen mode on Slave computer. Click “Esc” key to exit player and stop Slave Server. Meanwhile user can set fade in and fade out effects, longest time of the effect is 5000ms. Figure 5.1-11 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page33...
  • Page 34 Import/Export 1. Click Export to export database of Slave and Server configuration 2. Click Import to import database file that have been saved, this function can reduce time to configure the SlaveConfig and ServerConfig. Figure 5.1-12...
  • Page 35: Launch The Server

    To stop Server, right-click Server icon in the notification area, as shown in the below dialog box. Figure 5.2-3 Start Server Start Server and re-connect Master Stop Server Stop Server Exit Exit Server About PRO S3 MaxWall Server Show PRO S3 MaxWall Serer version and copyright PRO S3 Graphics MaxWall User Guide 7/7/2014 Page35...
  • Page 36: Chapter6 Master Feature Guide

    Click Wakeup Machine button. User can select wakeup Slave or Server Machine. Figure 6.1-1 Note:The default settings are as follows: Address: Slave Machine IP Port: 2020 Password: Admin (user can change this password on ServerConfig) PRO S3 Graphics MaxWall User Guide 7/7/2014 Page36...
  • Page 37 Align content to the right edge of the canvas Tile Window Arrange all the content windows in tile Maximum Maximum model Extend Extend content Align Grid Align content to grid Hide Hide content window Show Caption Show content window caption PRO S3 Graphics MaxWall User Guide 7/7/2014 Page37...
  • Page 38 The Current Task list shows the plans or missions that will be running on Slave. When running on Slave-slide, the model will be marked as “ONPLAY”. Move the mouse cursor over the item in the task list to show the tip information. PRO S3 Graphics MaxWall User Guide 7/7/2014...
  • Page 39 Model Window shows the model that is currently running on Slave-side, user can edit it in this window in real-time. Right-click the Source layer on model window, a dialog box will show as below: Figure 6.1-6 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page39...
  • Page 40 Show Property Selecting this option allows user to check the content information. Figure 6.1-7 Set Source These settings allow user to change the Source properties. Figure 6.1-8 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page40...
  • Page 41 Slave machine provides video signal devices including Capture Card, IP Camera, Video files, and APPS. Figure 6.1-9 Right-click the folder in source list and a menu will appear as shown below: Figure 6.1-10 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page41...
  • Page 42 Right click the IPC folder in source list: Figure 6.1-11 Add new IPC Click Probe Devices to show the list of IPC in intranet. User can move them to source list. Figure 6.1-12 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page42...
  • Page 43 Create a new source folder Create a new folder under IPC Figure 6.1-13 Change the descriptions Figure 6.1-14 Right click Web browser: Figure 6.1-15 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page43...
  • Page 44 1. Input the new source name. 2. Select the source type in pull-down menu. 3. Add description in Description Window. 4. Click OK button. Create a Source Filter Create a new file in Source List. Figure 6.1-17 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page44...
  • Page 45 Change Source Filter Description Figure 6.1-18 Right-click the source item in Source List, as shown in below menu: Figure 6.1-19 Rename Source Rename the source name. Figure 6.1-20 Delete Source Delete the selected source. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page45...
  • Page 46 Change Description User can check and update the source description. Figure 6.1-21 Show Property Click this option; open the dialog box as shown below to check base description. Figure 6.1-22 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page46...
  • Page 47 Set Source User can open this option to change source properties. Figure 6.1-23 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page47...
  • Page 48: Model

    Align Up Align content to the upper edge of the canvas Align Down Align content to the lower edge of the canvas Align Left Align content to the left edge of the canvas PRO S3 Graphics MaxWall User Guide 7/7/2014 Page48...
  • Page 49 Click this option to view model properties. 6.2.3 Source List Source list shows all the sources on Slave-side. User can directly drag the source into model windows during real-time control. User can refer to 6.1.4 Source List PRO S3 Graphics MaxWall User Guide 7/7/2014 Page49...
  • Page 50 Figure 6.2-4 6.2.5 Model Property Model Property shows the Selected Model Information that is in the Model List. Figure 6.2-5 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page50...
  • Page 51 Content Property shows the Selected Source Information that is in the Source List. Figure 6.2-6 6.2.7 Content List Content list shows the content information that is listed in the Model Window. Figure 6.2-7 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page51...
  • Page 52: Plan

    Note: Model duration must be more than 10s. Figure 6.3-1 6.3.1 Tools Bar Figure 6.3-2 Create a new plan Open Open a plan Delete Delete a plan PRO S3 Graphics MaxWall User Guide 7/7/2014 Page52...
  • Page 53 Right-click a plan to appear the dialog box as shown below: Figure 6.3-4 Rename Change plan name Delete Delete the selected plan. Change Description Change the selected plan information. Show Property Clicking this option enables user to check the plan properties. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page53...
  • Page 54 User can open several plans to edit at the same time. Right-click the model in plan window to appear the dialog box as shown below: Figure 6.3-6 Show Property Click this option to view the model properties. PRO S3 Graphics MaxWall User Guide 7/7/2014 Page54...
  • Page 55 Figure 6.3-7 Adjust Item Change the model duration time. Figure 6.3-8 6.3.4 Model List Model List shows all the models in Slave Server. User can refer to 6.2.2 Model List PRO S3 Graphics MaxWall User Guide 7/7/2014 Page55...
  • Page 56: Mission

    Run a mission Copy Copy mission item Paste Paste mission item Cut mission item Delete Delete mission item Align Up Align mission item upward Align Down Align mission item downward Zoom Zoom workspace PRO S3 Graphics MaxWall User Guide 7/7/2014 Page56...
  • Page 57 Figure 6.4-3 Mission window is the main user interface for editing the mission. It lists a week time. User can drag model or plan into mission window. 6.4.3 Model List Figure 6.4-4 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page57...
  • Page 58: Message

    User can refer to 5.2.2 Model List 6.4.4 Plan List Figure 6.4-5 User can refer to 6.3.2 Plan List Message Message provides scroll message function on Slave Figure 6.5-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page58...
  • Page 59: Options

    6.6 Options Option shows Slave properties, such as monitor resolution. Double-click “Screen Grid column” and “Screen Grid Row”, you can change their values. View current task. Figure 6.6-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page59...
  • Page 60: Chapter7 Rs232Tools

    7.1 Slave RS232 setting RS232 does not need to control the Slave via master, just connect to Slave directly. In slave machine: enter computer management Device managerPort, choose COM port, setting the property Figure 7.1-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page60...
  • Page 61 Open server config, choose ‟Use COM‟ Port: Set COM of the Slave as „1‟ BaudRate means Bits per second in Device Manger COM property, default is 9600 Figure 7.1-2 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page61...
  • Page 62: Master Rs232 Setting

    7.2 Master RS232 setting 1. In Server machine: enter computer management Device managerPort, choose COM port, setting the property Figure 7.2-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page62...
  • Page 63: Using Rs232T

    2. Open Rs232Tool,set the COM Port as COM3,Baud rate is 9600 Figure 7.2-2 7.3 Using RS232T 1. Click connect button to start RS232 control PRO S3 Graphics MaxWall User Guide 7/7/2014 Page63...
  • Page 64 Figure 7.3-1 2. Choose Model and click “RunSelectModel”, Slave will run the selected model Figure 7.3-2 3. Click “RunMission”to run the mission accordingly Figure 7.3-3 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page64...
  • Page 65: Chapter8 Smarttransmitter

    Chapter8 SmartTransmitter S3 SmartTransmitter is designed for uploading Windows desktop to slave for display. 8.1 SmartTransmitter installation SM@RTTransmitteSetup.msi to install the transmitter on which machine you want to upload its content. Figure 8.1-1 Figure 8.1-2...
  • Page 66 Figure 8.1-3 Figure 8.1-4 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page66...
  • Page 67 Figure 8.1-5 Figure 8.1-6 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page67...
  • Page 68: Run Smarttransmitter

    Click SM@RTTransmitter shotcut. Right click SmartTransmitter from the taskbar to list all the available slaves. Running it will click the tab and it will show your desktop to slave machine. Figure 8.2-1 PRO S3 Graphics MaxWall User Guide 7/7/2014 Page68...