PM1208M Wrist Gamma Indicator
Quick Start Guide
www. polimaster.com
polimaster@polimaster.com
To Start self-test
Linear analog
Press RESET button
During self-
test all LCD
segments will
flash for ~1 s
Circular analog
scale
indicates. We recommend to make this in
SELECT
button
After self-test the
Dose Equivalent Rate (DER) indication
mode will be switched, (
To select
DER
threshold
SET
mode
press and hold
SELECT button
To select
DER
references
modes press
DER value
SELECT button
The
To select
DE
threshold
SET
mode press and
hold SELECT
button
To select
DE
references
modes press
SELECT
button
To select
Time
SET
mode press
and hold SELECT
button
To select
Time
references
modes press
SELECT button
The
Communication with PC
additional settings (more detailed in p.3.2.6 of Manual)
IR adapter should
be directed to this
point from 10-20 cm
PCon word will
be indicated
Environmental operating conditions:
Temperature: 0 up to +45 °С ;
Humidity: up to 95% at 40°C ;
Water resistant to a depth of 100 m;
Environmental protection IP68
LIGHT
Clock arrow
scale
button
scroll button
WARNING.
Replace battery If bAtt
a special watch repair office
Sv/h)
Voice alarm sign
To turn on/off
voice alarm
and hold MODE
button 5 s
To select the
DE indication
mode press MODE button
Dose Equivalent (DE) indication
mode, (mSv)
To select the
indication
mode press
MODE button
The
Time indication
(hh.mm)
To select the
DER indication
mode press
MODE button
Time value
mode allows to make
To turn on
communication
mode press and
hold LIGHT
button
The
DER
threshold
mode, (linear scale is filled)
(Linear
To select next
reference
modes press
SELECT
button
The
DER
history
reference
MODE
button
(Linear
To select next
reference
modes press
SELECT
button
The
DER
mode, ( 00.00
(Linear
press
To return to
DER indication
press SELECT
button
The
DE
threshold
(Circular scale is filled)
Time
To select next
reference
modes press
SELECT
button
DE value
The
DE
mode,
To return to
DE indication
mode press
SELECT
button
The
Time reference
time will be shown at
To select indication of:
alarm time in hh.mm,
current day in DD.MM,
current year in YYYY,
PC
current time in mm.ss,
current time in hh.mm,
press SELECT button
reference
recording to
mode
registration
reference
will
displayed)
reference
mode,
Accumulated Time
reference
mode, (Alarm
first)
Current DER
threshold
value
(default value
is 99 99)
Current number
of recording
(d - - - means
history is full )
To record DER
value to history
press MODE
button
To start
registration
press MODE
button, DER
value will blink,
circular analog
scale will fill
Current DE
threshold
value
(default value is
99 99)
mode
Current DE
accumulated
time value
To turn on/off
alarm clock
press MODE
button
Sign of alarm clock
Need help?
Do you have a question about the PM1208M and is the answer not in the manual?