Page 1
S E C U R I T Y S Y S T E M 4110DL Installation Instructions • Installation Instructions • Installation Instructions N5672V3 10/96...
Page 2
Capability has been added for the control to call a pager on the secondary telephone number. This can only be used if the primary reporting format is Ademco Contact ID. The following entries have been added to program field *49 (Split/Dual Reporting) for the...
Keyswitch Operation ..............10 Section 5. TESTING THE SYSTEM ................11 REGULATORY AGENCY STATEMENTS..........12 DOC STATEMENT..................13 THE LIMITATIONS OF THIS ALARM SYSTEM ........14 SUMMARY OF CONNECTIONS DIAGRAM .... INSIDE BACK COVER ADEMCO LIMITED WARRANTY .......... BACK COVER –4–...
RECOMMENDATIONS FOR PROPER PROTECTION The Following Recommendations For The Location Of Fire And Burglary Detection Devices Help Provide Proper Coverage For The Protected Premises. Recommendations For Smoke And Heat Detectors With regard to the number and placement of smoke/heat detectors, we subscribe to the recommendations contained in the National Fire Protection Association's (NFPA) Standard #72 noted below.
Section 1. GENERAL DESCRIPTION The 4110DL is a microprocessor-based state-of-the-art security controls intended for wired applications. The Control Panel supports up to 6 hardwired zones and can be programmed either through the keypad or remotely using ADEMCO's V-LINK downloading software.
––––––––––––––––– ZONE RESPONSE TYPE CHARACTERISTICS –––––––––––––––––– Zone Response Type Characteristics 1 – Entry/Exit Burglary • Provides exit delay time when panel is armed in any arming mode. • Provides entry delay when panel is armed in Away and Stay modes only.
Section 2. SYSTEM INSTALLATION AND WIRING ––––––––––––––––––––––––– INSTALLING THE SYSTEM ––––––––––––––––––––––– Refer to the Summary of Connections diagram on the inside back cover of this manual for terminal connections when following these procedures. 1. Mount the Control Cabinet. 2. Mount the PC board. BE SURE TO USE THE PLASTIC MOUNTING CLIPS (SUPPLIED) TO ISOLATE THE CIRCUIT BOARDS FROM THE CABINET.
Section 3. PROGRAMMING THE SYSTEM ––––––––––––––––––– THE MECHANICS OF PROGRAMMING –––––––––––––––– For actual program fields, refer to the programming form included at the center of this manual. Entering Program Mode Use one of the following methods: • Press both the [*] and [#] keys at the same time within 50 seconds after power is appled to the Control. •...
Section 4: SYSTEM OPERATION –––––––––––––––––––––––––––– USER ACCESS CODES ––––––––––––––––––––––––––– Adding a Secondary User Code MASTER CODE + [CODE KEY] + USER # ( 2, 3, OR 4) + DESIRED 4-DIGIT ACCESS CODE. (The system will emit a single beep when a secondary code has been successfully entered.) Deleting a Secondary User Code MASTER CODE + [CODE KEY] + USER # (2, 3 OR 4) Notes:...
Section 5. TESTING THE SYSTEM After installation is completed, the Security System should be carefully tested, as follows: Test Mode 1. With the system in the disarmed state, check that all zones are intact. If a NOT READY message is displayed, press the [ ] key to display the faulted zone(s). Restore faulted zone(s) if necessary.
REGULATORY AGENCY STATEMENTS UL NOTICE: This is a "Grade A" residential system. FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15 STATEMENT This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC requires the following statement for your information: This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in strict accordance with the manufacturer's instructions, may cause interference to radio and television reception.
CANADIAN DEPARTMENT OF COMMUNICATIONS (DOC) STATEMENT NOTICE The Canadian Department of Communications label identifies certified equipment. This certification means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company.
WARNING THE LIMITATIONS OF THIS ALARM SYSTEM While this System is an advanced design security system, it does not offer guaranteed protection against burglary, fire or other emergency. Any alarm system, whether commercial or residential, is sub ject to compromise or failure to warn for a vari ety of reasons.
Page 15
STEADY FOR BURGLARY/PANIC, IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) IT MAY NOT No. 6137: 85mA PULSING FOR FIRE (e.g. USE ADEMCO CAUSE HARMFUL INTERFERENCE, (2) IT MUST ACCEPT ANY INTER- AL FIRE PROTECTION ASSOC., BATTERYMARCH No. 702 OR 719 SIREN, OR 12V BELL) FERENCE THAT MAY CAUSE UNDESIRED OPERATION.
24 months from the date stamp con trol on the product or, for products not having an Ademco date stamp, for 12 months from date of original purchase unless the installation instructions or catalog sets forth a shorter period, in which case the shorter period shall apply.