GENERAL WARNINGS When installing, be sure to carefully follow the instructions given in this manual. The manufacturer declines all responsibilities for damage to equipment or people caused by non-standard system installations or modifications. NOTES When indicated, the right side of the vehicle is the “passenger side” and the left side of the vehicle is the “drivers side”. Contents Page MAIN COMPONENTS –...
Page 4
Description EVAPORATOR CONNECTION KIT CONDENSER CONDENSER MOUNTING KIT COMPRESSOR BOX COMPRESSOR BOX MOUNTING KIT TECHNICAL DATA Cooling Capacity: Up to 6100 BTU Power Consumption: Up to 62A (12V) Functioning with Engine Off: Voltage: 12V DC Refrigerant: R-134A 6 Ventilation Speeds Electronic temperature control with digital control panel Auto –...
Page 11
Evaporator MUST be mounted as high as possible in the sleeper area. The unit cannot be mounted under the bunk. NOTE: Install return air vents if unit is enclosed in a cabinet.
ELECTRIC DIAGRAM COLOR CODE COLOR CODE COLOR CODE WHITE BROWN GREEN YELLOW BLACK WHITE/RED GRAY RED/BLACK...
Page 16
All 4 buttons must be pressed at the same time...
Page 17
OPERATION / CONTROL PANEL “SLEEPING WELL ARCTIC PLUS” CAN BE USED BY ACTIVATING THE AIR CONDITIONING OR THE FAN FUNCTION ONLY. CONDITIONING (AC) : TEMPERATURE SET BY USER : AMBIENT TEMPERATURE DETECTED BY PROBE : COMPRESSOR ROTATION SPEED (2500 Rpm) : COMPRESSOR ROTATION SPEED (4000 Rpm) ON/OFF When the system is OFF, press the ON/OFF button (see fig.
Page 18
ERRORS SHOWN ON THE DISPLAY (AC / FAN) Description Message Symbol Battery Voltage (The battery-saver device has cut out. Voltage has fallen below the value of 10.8V D.C.) Fan Over Current Cut-Out (The condenser or evaporator fan overloads the central control unit above the limit allowed.
Page 19
REFRIGERANT FILLING PROCEDURE Before charging the system, (by means of the charge fittings on the condenser unit and compressor block) run vacuum cycle for 30 minutes. Disconnect the high-pressure attachment. Charge the system with 17.6oz (500 grams) R-134a into the circuit through the low-pressure attachment.
Page 20
SYSTEM MAINTENANCE Condenser Compressor Box Evaporator Batteries (Accessory) Spring Visual Inspection Visual Inspection Visual Inspection Visual Inspection Summer Fall Visual Inspection Visual Inspection Visual Inspection Visual Inspection Winter Condenser - Visual Inspection - Core should be clear/free of dirt and debris. Bracket mounting bolts are tight and secure to rear exterior sleeper wall.