Panamax MB1000 Instructions Manual
Panamax MB1000 Instructions Manual

Panamax MB1000 Instructions Manual

Fully programmable, uninterruptible power supply, voltage regulator & power conditioner
Hide thumbs Also See for MB1000:

Advertisement

MB1000 Instructions
A Fully Programmable, Uninterruptible Power Supply, Voltage Regulator & Power Conditioner
FAULT
Features:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MB1000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Panamax MB1000

  • Page 1 MB1000 Instructions A Fully Programmable, Uninterruptible Power Supply, Voltage Regulator & Power Conditioner FAULT Features:...
  • Page 2 Table of Contents Before You Begin UNPACKING Inspect the UPS upon receipt.
  • Page 3: Important Safety Instructions

    The MB1000 has a handling capacity of 1000VA or approxi- mately 600 watts. Excessive power consumption beyond CAUTION! The battery can energize hazardous live parts these specifications can affect battery life and performance.
  • Page 4: Installing Your Ups

    Installing Your UPS HARDWARE INSTALLATION GUIDE 4. Press and hold the power switch for 2 seconds to turn the UPS on. The display will say “Initializing”, followed by the 1. Your new UPS may be used immediately upon receipt. normal operation screen. However, recharging the battery for at least four hours is recom- mended to insure that the battery’s maximum charge capacity is 5.
  • Page 5 BANKS WIRING FAULT POWER MENU MB1000 Line Fault Indicator Outlet Bank 2 Indicator Outlet Bank 1 Indicator This LED will illuminate in red to warn the user that a wiring problem such as a bad/miss- Illuminated blue when outlet Illuminated blue when outlet ing ground or reversed wiring exists within the AC receptacle.
  • Page 6: Operating Modes

    Sensitive AVR: when receiving input voltages of 98 VAC – 135 CCW rotation of the navigation dial DECREASES the selected VAC, the MB1000 supplies a regulated voltage of 120 VAC ± 5 parameter, or goes back to the PREVIOUS value. Pressing the VAC.
  • Page 7 IR2 SETUP IR2 TEST IR2 PROGRAM IR2 SAMPLE FAIL Pass/ Fail Fail IR2 SAMPLED Pass BACK IR OUTPUT DELAY IR OUTPUT DELAY XXX SEC BACK BUZZER MODE BUZZER MODE UPS TEST RUN TEST? XXX PANAMAX MB1000 SYSTEM INFO FIRMWARE REV A...
  • Page 8: Advanced Operation

    Setup for Automatic Voltage Regulation parameters. but not limited to Pro Audio, Broadcast and High-End Home Theater equipment. The MB1000 takes this to the next level with Outlet Bank 2 Setup a number of features designed specifically for AC Power back up Adjusts the battery charge threshold in which Outlet Bank 2 is applications.
  • Page 9: Rs-232 Communications Protocol & Command Set

    Advanced Operation RS-232 Communications Protocol & Command Set RS-232 Control with Open Protocol 2. If the delay settings are the same for both IR1 and IR2, the IR2 The RS-232 serial interface can be used in the following ways: code will be sent to both outputs 2 seconds after IR1. 1.
  • Page 10 MB1000. Connector Pin-out: Note: Responses are only transmitted if unsolicited feedback is Pin 2, Transmit. The MB1000 transmits data on this pin. enabled (!SET_FEEDBACK) Pin 3, Receive. The MB1000 receives data on this pin. Pin 5, SG (signal ground).
  • Page 11 RS-232 Communications Protocol & Command Set SWITCH OUTLET BANK SET BANK 2 THRESHOLD Turns a specific outlet bank on or off. Switching is immediate Sets the battery level threshold in which Outlet Bank 2 shuts off. with no delay. Send to UPS: !SET_BATTHRESH level<CR>...
  • Page 12 RS-232 Communications Protocol & Command Set SET AVR MODE SET METER BRIGHTNESS Sets AVR (Automatic Voltage Regulation) MODE. Sets the LCD display and outlet bank indicator brightness. Command: !SET_AVR mode<CR> Send to UPS: !SET_BRIGHT xxx<CR> mode = {OFF, STANDARD, SENSITIVE} xxx = {100, 075, 050, 025} _________________________________________ _________________________________________...
  • Page 13 Model number and firmware revision will be provided. Send Query to UPS: ?POWER<CR> Response: $PANAMAX<CR> Action: Voltage status messages will be $MB1000<CR> displayed $FIRMWARE revision<CR> _________________________________________ Response: $VOLTS_IN = vvv<CR> OUTLET STATUS $VOLTS_OUT = vvv<CR> Requests the on/off status of the outlet banks $WATTS = xxxx<CR>...
  • Page 14 RS-232 Communications Protocol & Command Set BATTERY LEVEL STATUS !SET_BRIGHT<CR> ?VOLTAGE<CR> Requests the battery level, expressed as a percentage of maxi- !SET_SCROLLMODE<CR> ?LOADSTAT<CR> mum (full charge). !SET_SLEEPMODE<CR> ?BATTERYSTAT<CR> ?ID<CR> ?LIST_CONFIG<CR> Send Query to UPS: ?BATTERYSTAT<CR> ?OUTLETSTAT<CR> ?HELP<CR> ?POWERSTAT<CR> _________________________________________ Action: Load level will be displayed RESPONSES &...
  • Page 15: Fcc Notice And Warranties

    WARRANTY LIMITATION FOR INTERNET PURCHASERS Panamax warrants to the purchaser of this Panamax audio/video Panamax products purchased through the Internet do not carry a valid component style uninterruptible power supply, for a period of three (3) Connected Equipment Protection Policy unless purchased from an Au-...