3. Technical Parameter Items Specification Parameter Rated Voltage 220 V AC Electrical Rated Frequency 50 Hz Performance Rated General Power 1000 W Rated General Current 5.8A Hot Tank Volume 1.8L Heating System Heating Power 900 W Heating Capacity 10L/h ≧90℃ Hot Water Temp.
5. Installation 5.1 In General This machine is only suitable for indoor use and must be installed in a cool, ventilated, stable surface, away from hot objects. Leave at least 10cm (4’’) space at the back of the machine and leave enough space for machine at the right and left side.
A-2 in Picture 3. Picture 3 5.3 Connect with Waste Water Discharge (RO Version) Connect the one side of PE pipe with waste water drain connector and another side into the floor drain or other reliable container. (Please refer the Picture 3) For RO version, during making the pure water, machine also produces waste water.
heating switch is on, and there no water in hot tank, the heating element will be burnt. • Check if the cooling switch is in switch off position, if not, please turn it off. • Check if the socket this machine use is well grounded, make sure the socket is work properly. (Note: this machine has high-power heating system, it must use three holes socket that can load at least 10A current.) 6.2.
Note: This clause only applies to the machine with cooling system. 7.4. Sterilization System 7.4.1 Ozone System Forced sterilization: After filling water process is finished, push ozone switch at the back of machine, machine entering sterilizing mode. The ozone icon lights on, 3 minutes later the process stopping, and the zone icon will shin for 10minutes then light off.
getting hot water.(if doesn’t push any buttons, 1 minutes later machine stop hot water outlet automatically ) Note: This clause only applies to the machine with heating system. 8.2 Get Cold Water 8.2.1. Get One Cup of Cold Water Push water button to get 200ml cold water.
Page 13
Filter Replacement To clean every 3 to 6 month Pre-Filter Change every 6 month ACF Filter change every 6 to 12 month Compound Filter RO Filter change every 12 to 18 month UF Filter change every 12 to 18 month Note: the replacement period recommended in the above table is for general water condition, it is just for reference only.
Page 14
Picture 5 Open— Turn the filter out (Counter clockwise) Close—Install filter (clockwise) Picture 6 9.1.4. How to replace UV After remove the decorative panel you can see on the top there is UV installed. (see picture 4) . Please do accordingly as following to replace UV. Taking off UV(Open).
The ozone generator is installed at the bottom of the machine (See picture 8). Cause the replacement of ozone generator leads to install of electrical parts, we suggest the replacement of ozone will be taken by professional service people. It is described in detail here.
First please turn off the water supply and electricity supply. Remove the decorative panel, you will see the hot tank cover (check Picture 4). Use tool to open the hot tank cover, then put clean water into hot tank. Use soft cloth or soft brush to clean the hot tank. After that, take off the hot tank drain stopper at the bottom of machine.
10. Precautions ◎The machine is only for indoor use, please do not put under direct sunlight. Do not put flammable material beside the machine. Do not put valuable appliance beside machine to prevent being damp. Do not sink machine into water. ◎This machine adopts the 230VAC or 120vac voltage , need to use with a 10A fuse socket.
11. Trouble Shootings If you find machine not work properly, please check the list blow, and then decide if you need to find professional person to repair. Failure Possible Reason Settlement •Check if machine has connected to power •haven’t connect to power supply supply •Power socket failure No water comes...