SHILOH TR002B Owner's Manual

High-efficiency woodstove

Advertisement

Quick Links

HIGH-EFFICIENCY WOODSTOVE
Model TR002B Owners Manual
Le manuel de langue français est disponible à www.vogelzang.com
READ ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING
THIS STOVE. FAILURE TO FOLLOW INSTRUC-
TIONS MAY RESULT IN PROPERTY DAMAGE,
BODILY INJURY, OR EVEN DEATH.
REFER TO MARKINGS ON STOVE LABELS FOR
ADDITIONAL INFORMATION.
SAFETY NOTICE: IF THIS STOVE IS NOT PROPERLY INSTALLED, A HOUSE/BUILDING FIRE MAY
RESULT. FOR YOUR SAFETY, CONTACT LOCAL OR MUNICIPAL BUILDING OR FIRE OFFICIALS
ABOUT PERMITS, RESTRICTIONS, AND INSTALLATION REQUIREMENTS FOR YOUR AREA.
TR002B | 20120125.0
THE SHILOH
EPA Certified (4.22 grams/hr)
(Save These Instructions)
French language manual is available at www.vogelzang.com
www.vogelzang.com
This stove meets test standards:
US: UL 1482-2010 & CDN: ULC-S627-00
NOTE: IT IS RECOMMENDED INSTALLATION
BE COMPLETED BY A QUALIFIED HEATING
EQUIPMENT INSTALLER!
DO NOT INSTALL IN A MOBILE HOME.
Vogelzang International Corporation
400 West 17th Street
Holland, Michigan 49423
www.vogelzang.com
Phone: 1-616-396-1911
Fax: 1-616-396-1971
Report No. 235-S-01c-2
SHILOH™ | Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TR002B and is the answer not in the manual?

Questions and answers

Summary of Contents for SHILOH TR002B

  • Page 1 THE SHILOH ™ HIGH-EFFICIENCY WOODSTOVE EPA Certified (4.22 grams/hr) Model TR002B Owners Manual (Save These Instructions) Le manuel de langue français est disponible à www.vogelzang.com French language manual is available at www.vogelzang.com Report No. 235-S-01c-2 This stove meets test standards: READ ALL INSTRUCTIONS CAREFULLY US: UL 1482-2010 &...
  • Page 2: Safety Precautions

    FLUE SERVING ANOTHER APPLIANCE. 18. The special paints used on your stove may give 9. DO NOT CONNECT A WOOD BURNING STOVE TO off some smoke and an odor while they are cur- Vogelzang International Corp. Page 2 | SHILOH™ TR002B | 20120125.0...
  • Page 3 Association (NFPA) publication, “Using Coal and door open. Always close the door after ignition. Wood Stoves Safely” NFPA No. HS-10-1978. Write 29. DO NOT CONNECT TO OR USE IN CONJUNC- NFPA, Batterymarch Park, Quincy, MA 02269. www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 3...
  • Page 4: Table Of Contents

    Glass Gasket Replacement ..............20 Door Gasket Replacement ..............21 OPTIONAL F-6 BLOWER MAINTENANCE & WIRING DIAGRAM ....21 PARTS – SHILOH™ ..................22 PARTS – GLASS DOOR ..................23 PARTS – FIRE BRICK ..................23 FLOOR PROTECTOR CALCULATIONS ............24 CHIMNEY &...
  • Page 5: Tools And Materials Required For Installation

    Figure 1 – DO NOT remove ceramic blanket from positioned toward the front and attach with six (6) inside stove pipe opening. This is NOT packing material but an integral component of the stove continued on next page combustion system. www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 5...
  • Page 6: Assembly Instructions

    9. Tip the stove assembly upright. properly positioned and ash cleanout cover is in 10. Set the ash drawer inside the open box formed by place. the pedestal front and sides. Vogelzang International Corp. Page 6 | SHILOH™ TR002B | 20120125.0...
  • Page 7: Locating The Stove

    According to UL 1482-2006 FLOOR FLOOR 16"/40.6cm min. 18"/46.8cm min. PROTECTOR PROTECTOR 15"/38.1cm 15"/38.1cm 23"/54.5cm 6"/15.2cm min. 23"/54.5cm 8"/20.3cm min. min. min. Fig. 10 – Top View Minimum Clearance Dimensions from Combustible Surfaces www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 7...
  • Page 8: Minimum Clearances

    Fig. 12a – Front View Fig. 12b – Side View Fig. 12c – Front View Fig. 12d – Side View Minimum Clearance Dimensions Minimum Clearance Dimensions from Combustible Surfaces from Combustible Surfaces Vogelzang International Corp. Page 8 | SHILOH™ TR002B | 20120125.0...
  • Page 9: Firebrick Assembly

    Fig. 13a– Step 1, Bottom Firebrick Installation Two (2) FF-Size; Two (2) T-Size; Two (2) X -Size; One (1) Y-Size; One (1) Z-Size Fig. 13c– Step 3, Back Firebrick Installation Four (4) A-Size www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 9...
  • Page 10: Connector Pipe Installation

    CONNECTOR PIPE AS A CHIMNEY - A HOUSE 2. Horizontal pipe must slope up towards the chimney FIRE COULD RESULT. at least 1/4˝/6.4mm per foot of horizontal run. CORRECT WRONG WRONG Fig. 14 – Stovepipe/Flue Connections Vogelzang International Corp. Page 10 | SHILOH™ TR002B | 20120125.0...
  • Page 11: Chimney Sizing

    BELOW ENTRY Should you have a problem with inadequate draft, HOLE you should contact a licensed heating and cooling contractor for assistance in solving the problem. Fig.15 - Masonry Chimney Connection www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 11...
  • Page 12 HVAC supply stores. You may wish to view chimney manufacturers’ information on-line. See, www.duravent.com, www. selkirkinc.com, or www.mtlfab.com. Fig. 17 - Chimney Construction Through Roof continued on next page Vogelzang International Corp. Page 12 | SHILOH™ TR002B | 20120125.0...
  • Page 13 The stove war- ranty will be void with such an installation. Do not create a hazard in your home by connecting in this manner. Fig. 19 - Fireplace Conversion www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 13...
  • Page 14 Fire Protection Association (NFPA) and request a copy of the latest editions of NFPA Standard 211 and NFPA Standard 908. Their address is: National Fire Protection Association Battery March Park, Quincy, MA 02269. Vogelzang International Corp. Page 14 | SHILOH™ TR002B | 20120125.0...
  • Page 15: Chimney Connection Systems & Clearances

    24 gauge thickness. Fasteners used to secure chimney section shall not penetrate chimney flue liner. www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 15...
  • Page 16: Operating Instructions

    VICINITY OF THE STOVE— WHETHER IN USE mance. Actual performance is dependent on chimney OR IN STORAGE. height, weather, log size, wood species and moisture continued on next page Vogelzang International Corp. Page 16 | SHILOH™ TR002B | 20120125.0...
  • Page 17: Starting A Fire

    flame spillage. 4. Ignite the paper and leave the door open slightly. continued on next page www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 17...
  • Page 18: Service Hints

    The use of green or wet wood will cause a rapid build up of creosote. Wood that hisses, sizzles and blackens without igniting in five minutes must be considered too wet to burn. continued on next page Vogelzang International Corp. Page 18 | SHILOH™ TR002B | 20120125.0...
  • Page 19: Chimney Draft

    Without the correct amount of draft, the stove will not the stove or chimney starts to glow, you are over operate properly. firing the stove. Masonry chimneys will take longer If there is excessive draft, an unsafe condition will www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 19...
  • Page 20: Glass Care & Replacement

    3. Do not build fires against (or that might fall against) the glass. 4. Do not clean the glass with materials that may Vogelzang International Corp. Page 20 | SHILOH™ TR002B | 20120125.0...
  • Page 21: Door Gasket Replacement

    AND WHENEVER SERVICING BLOWER ASSEMBLY. NOTICE: ANY REPLACE- MENT WIRING MUST HAVE E Q U I VA L E N T I N S U L A - TION AND TEMPERATURE RATING (105°C). www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 21...
  • Page 22: Parts - Shiloh

    ORDERING PARTS - TROO2B SHILOH™ STOVE When ordering missing or replacement parts, always give the of the stove, , and Part Description. Use the illustrations and part lists provided to identify parts. Contact us at 616-396-1911 to order parts. 5, 6...
  • Page 23: Parts - Glass Door

    Fire Brick M-size ........... 2 2B-11T Fire Brick T-size ..........2 2B-11X Fire Brick X-size ........... 1 2B-11Y Fire Brick Y-size ..........1 2B-11Z Fire Brick Z-size ..........2 Fire Brick: Back Fire Brick: Bottom www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 23...
  • Page 24: Floor Protector Calculations

    Rbrick + Rmin.brd = 0.80 + 0.431 = 1.231 = Rsystem Step 4: Compare Rsystem to Rspecs Rsystem = 1.231 is larger than Rspecs of 0.893. System R-value exceeds the required specifications and therefore is an acceptable alternative. Vogelzang International Corp. Page 24 | SHILOH™ TR002B | 20120125.0...
  • Page 25: Chimney & Stove Maintenace Log

    CHIMNEY & STOVE MAINTENANCE LOG DATE OF SERVICE PERFORMED BY DESCRIPTION www.vogelzang.com TR002B | 20120125.0 SHILOH™ | Page 25...
  • Page 26 BELIEVES IN HIM SHALL NOT PERISH BUT HAVE ETERNAL LIFE” JOHN 3:16 MADE IN CHINA Vogelzang International Corporation 400 West 17th Street Holland, Michigan 49423 www.vogelzang.com Phone: 1-616-396-1911 Fax: 1-616-396-1971 Vogelzang International Corp. Page 26 | SHILOH™ TR002B | 20120125.0...

Table of Contents