  • Page 1: Installation And Safety

    LC Plus LED Video Display Panel Installation and Safety Manual...
  • Page 2: Dimensions

    The Martin logo, the Martin name and all other trademarks in this document pertaining to services or products by Martin Professional A/S or its affiliates and subsidiaries are trademarks owned or licensed by Martin Professional A/S or its affiliates or subsidiaries.
  • Page 3: Safety Information

    (protective earth). • Connect LC Plus panels to AC power and to each other using the 16 A rated, UL-listed, 16 AWG cables supplied by Martin for this product. Replacement power cables from other sources can be used as an alternative, but they must be 3-conductor Hypalon or neoprene rubber-jacket, approved for a current of 16 A and temperature of 90°...
  • Page 4 • Connect no more than five LC Plus panels in total to AC mains power in one chain using the power output (throughput) connectors in the base of the product. • When using the product in a wet location, use only the Amphenol IP67-rated connectors supplied by Martin and specified in this manual.
  • Page 5: Table Of Contents

    LC Plus flightcases ........
  • Page 6: Connections Overview

    (or a standard Ethernet connector for Warning! A maximum of FIVE LC Plus 2140 indoor use only). panels in total or TEN LC Plus 1140 panels in Warning! All connectors that are not in use total may be connected to power in one chain must be sealed at all times with the caps that draws power through the first panel’s...
  • Page 7: Introduction

    Unpacking LC Plus Series products are packaged either in sets of 4 panels in a 4-unit flightcase or as single panels in a cardboard box. The following items are included.
  • Page 8: Using For The First Time

    • 4 x 1.5 m (4.9 ft.) Ethernet patch cables with IP67 RJ-45 connectors: P/N 11840140 • LC Plus Installation and Safety Manual: P/N 35000218 * Threaded spigots for conical couplers in the Martin LC Plus are not interchangeable with the threaded spigots for the standard Martin LC Series.
  • Page 9: Physical Installation

    Figure 3: Safety limits for stacking and suspending attached panels Standing installation See Figure 3. One vertical stack with LC Plus 1140 panels resting on each other may contain a maximum of nine LC Plus 1140 panels stacked upright or eight LC Plus 1140 panels stacked on their sides.
  • Page 10: Flying From A Truss, Bar Or Other Structure

    One vertical stack with LC Plus 2140 panels resting on each other may contain a maximum of seven LC Plus 2140 panels stacked upright or five LC Plus 2140 panels stacked on their sides. An unlimited number of stacks of panels may be installed alongside each other.
  • Page 11 7. As soon as a panel is fastened in place, install two safety cables to secure it. Safety attachments must be able to bear at least 10 times the weight of all the panels they secure. See Figure 6. Loop safety cables in a figure-of-eight around vertical side columns and the supporting structure or the panel above so that if a rigging clamp or conical...
  • Page 12: Ac Power

    Disconnect the entire installation from power before carrying out installation work. Warning! A maximum of FIVE LC Plus 2140 panels in total or TEN LC Plus 1140 panels in total may be interconnected using power throughput connectors to form one chain that draws power via the first panel’s power input cable.
  • Page 13: Power Connection

    Amphenol C016 20 D 003 100 12 cable connector (female, IP67- rated). Power can be relayed to another LC Plus panel via the throughput socket (see E in Figure 1 on page 6). This socket accepts an Amphenol C016 20 H 003 100 12 cable connector (male, IP67- rated).
  • Page 14 Figure 9: Amphenol power cable connector assembly instructions The Amphenol C016 ecomate series power cable connectors used with the LC Plus accept power cable from 6 mm (0.24 in.) to 9 mm (0.35 in.) diameter when fitted with a standard cable gasket, or from 9 mm (0.35 in.) to 12.5 mm (0.5 in.) diameter when fitted with an optional heavy gauge cable gasket.
  • Page 15 Power plugs and power outlet sockets A power plug must be installed on the power input cable so that you can connect LC Plus panels to AC mains power. Install a grounding-type (earthed) industrial 3-prong type B plug (see Figure 10) that complies with IEC 60309 or a comparable national standard and is rated 16 A minimum, and use corresponding power outlet sockets.
  • Page 16: P3 Communication Link

    Each LC Plus panel has two RJ-45 Ethernet sockets (see A and B in Figure 1 on page 6) for connection to the P3 link. All sockets are bi-directional, handling both P3 signal input and output.
  • Page 17 P3 system layout: schematic overview P3-100 System Controller P3 signal Analog video Mouse Analog Keyboard video Monitor 1GB Ethernet switch required if installation exceeds 50 panels Max. 50 panels per daisy-chain 1GB Ethernet switch required if cable length exceeds 100 m 100 m cable Figure 11: Schematic diagram of P3 system connections...
  • Page 18: Connecting The P3 Link

    1. Plug an Ethernet patch cable running from the P3-100 System Controller’s P3 signal output socket into one of the RJ-45 Ethernet ports on the first LC Plus panel (it does not matter which port you use, as both P3 connectors can be used for input and output). In outdoor or wet locations, an IP67-rated Amphenol RJF RB 6 housing must be installed on the RJ-45 plug.
  • Page 19: Configuration And Testing

    This section covers the needs of the installer and technician only. It explains the options available for configuration and testing of LC Plus panels, but it does not explain how to allocate addresses to panels or the options available for displaying video. For details of these, see the P3-100 System Controller user documentation.
  • Page 20 2140 Panel model number (either 2140 or 1140) PLUS Identifies panel as LC Plus. Table 4: Start-up display messages The boot process generally takes approximately 4 seconds. When it is completed, the panel displays its address. It will continue to display its address permanently unless the control menus are activated.
  • Page 21: Resetting And Rebooting Panels

    Resetting and rebooting panels If it becomes necessary to reset an LC Plus panel, it is possible to force a 'normal reboot' (which causes the panel to reset and start up as it normally would when power is applied), or a 'factory reboot' (which causes the panel to start up the original factory-programmed firmware).
  • Page 22: Service And Maintenance

    The user will need to carry out periodic cleaning, and it is also possible for the user to update the LC Plus firmware quickly and easily from the P3-100 System Controller. All other service operations must be carried out by Martin Professional or its approved service agents.
  • Page 23: Troubleshooting

    Fault on P3 link. One or more panels displays connections. Repair or replace damaged cables. video incorrectly or does not Have faulty panel serviced by Martin service display video at all. Panel defective. technician. Other device (e.g. Ethernet switch) on P3 link Replace with a device known to be operating defective.
  • Page 24: Specifications

    Video signal processor ..... . . External P3-100 System Controller (one per system) Processor capacity ......500 000 pixels (400 LC Plus 2140 panels) with P3-100 Output resolution .
  • Page 25 Total heat dissipation, LC Plus 2140 (calculated) ........
  • Page 26 Four-unit flightcase for 4 x LC Plus 2140 video panels ......