Control Module
DVTH132 A/F/AF
Owner' s Guide
T hank you for choosin g the DVTH132, a programmable
thermost at that provid es both energy savings and total
comfort.
Install the Control Module
Align the b racket t abs o n the control module with th e
holes loca ted on top of the po wer base.
T his co ntrol module must be i nstalled on a PB1 30 series
power bas e.
Control module
Air vent s
Power base
Note:
Keep the thermostat's air vents clean and free from
obstruc tions.
Note:
The screw cannot be removed completely .
DVTH132 Description
DAY/H OUR/MIN —Set the day and clock settings.
PGM—Program the schedule (progra ms).
MODE—Select the ope rating mode .
RETURN—To exit a function.
To configu re temperature setpoints:
,
Comfort
Economy and
Adjust the fl oor temperature limit (AF only).
—Increase and decrease temperature.
—Indicates the number of the curren t
program when Automatic mode is enab led.
Current operating mode (a uto
Auto mode, the program's associated setpoint icon is
also displayed (
).
Indica tes the room OR floor temperature.
Heating indicators (see "Temperature Control"
below).
First Power ON
On the first inst allation, the screen displays:
0:00 , MO,
and temperature (room/flo or).
For Fl oo r He ating Installation s:
One of the two foll owing messages may be dis-
played when a probl em occurs:
Air vent s
LO
: T he floor temperature is below 0°C,
the temperature sensor is de fective, or not
connected.
T he heating indicator
is displaye d and
the rela y is close d (e nergized).
HI
: T he floor temperature is abo ve
60°C , or the temperature sensor is
defective.
Set the Time and Day
Set t he time (HOUR - MI N) .
Set the day (DAY ).
If you remove the module from it s base for more than
2 hours, the time and day will have to be reprogramme d.
Models Overview
DVTH1 32-A
Thi s model h as been desi gned to control a room's ambi-
ent tempe rature.
The DVT H132-A has one temperature sensor loca ted
in the control module.
DVTH1 32-AF
Vaca tion.
Thi s model is designed to use a floor sens or to co ntrol the
room tempe rature.
The DVTH132-AF has two temperature sensors:
•
T he first one, inst alle d in the control module, controls
the a mbient temperature.
•
T he seco nd one , inst alled in the fl oor (and connected
/
manual
). In
to the power b ase), li mits the temp erature of the floor
(the default settin g of this limit is 28°C).
DVTH1 32-F
Thi s model is designed to co ntrol floor hea ting systems.
The DVT H132-F ha s one temperature sensor inst alled
in the floor (sensor is connected to the powe r base).
Adjust the Temperature Setpoints
Comfort
and Econo my
Th ese setp oints are associat ed with the schedule's pro-
grams (prog. 1 & 3 = Comfort, prog . 2 & 4 = Economy)
and are preprogrammed as fol lows:
A & AF mode ls—
or
F mode l—
28°C,
To modify a set point:
Set the temperature using
or
button until it is displ ayed on the screen .
Press MODE/RETURN to exit.
Vacat ion Set point
Th e vaca tion se tpoint is associated to the V acation oper-
ating mode an d is preprogrammed to 10 °C. T o modify this
setpoint, repeat above step s.
Floo r Temperat ure Se tpoin t (AF mode l on ly )
Th e floor te mperature limit is preprogrammed to 28 °C to
avoid damage to your floor.
To modify, p res s the a djustment bu tton (bel ow
pointed object, set the de sired temperature using
press MODE/RETURN to exit.
Configure the Switches
DVTH 132
part on the rea r of the control module, which are used to
set the fo llowing options:
Early Start
W hen the Early Start function is en able d (disabled by
default), DVTH132 calculates the optimum system start
time to obtain the d esired temperature by the se t time. To
enable this function:
Po sition switch #1 down .
Note:
Whe n this function is enabled, the
system can be activated before the pro-
gram's st art time.
Tempera tur e Dis pla y
By de fault, DVT H132 displa ys the temperature in °C. If
you wish to change to °F:
Po sition switch #2 up.
Note:
When you switch from °C to
versa , the
redefined.
Select the Operating Mode
Set point s
DVT H132 o ffers three operating modes:
Au toma tic
P ress MO DE to select
program number is displaye d.
20°C,
18°C
You can temporarily byp ass th e current
20°C
program b y settin g a spec ific temperature setpoin t
or by sele cting one of the pre-defin ed setpoin t
buttons (
and press and hold the
until the beg inning of the next program.
Ma nual
P ress MO DE to select
Se t tempera ture
defined se tpoint buttons (
Vaca tion
during a prolonged ab sence.
Pr es s
) using a
and
has two switche s, located on the upper-left
°F or vice
,
a nd
setpoi nts must be
—
Exe cutes the sche dule.
. T he c urrent
). Th e new se tpoint will be maint ained
—Maintains a constant temperature.
.
or select one of the pre-
).
—Maintains the V acation setpoint
.
DVK 132-000-A