Power Led Blinking Timing Chart - Panasonic TX-37LZD80F Service Manual

Hide thumbs Also See for TX-37LZD80F:
Table of Contents

Advertisement

Power LED blinking timing chart

1.
Subject
Information of LED Flashing timing chart.
2.
Contents
When abnormality has occurred the unit, the protection circuit operates and reset to the stand by mode. At this time, the
defective block can be identified by number of blinking of the Power LED on the front panel of the unit.
Blinking
times
Once
1
2
3
4
5
6
7
8
9
13
Blinking timing
4 sec
Light
No Light
13
Contents
A BOARD, P BOARD
INVERTER_SOS
FAN_SOS
SOS
DTV_12V
MAIN_9V
SUB_5V
A BOARD, M BOARD
SUB_3.3V
MAIN_3.3V
SOUND_SOS
Emergency SOS
Check point
LCD PANEL
A BOARD
A BOARD
P BOARD
P BOARD
A BOARD
A BOARD
P BOARD
A BOARD
A BOARD
A BOARD
A BOARD