WARNING
Before installation inspect each vent component for damage and correct seal placement. Do not
attempt to fix or install any damaged vent components.
Condensate
When the total vent system length is greater than 5 ft. (1,52 m), condensate will form which could damage
the water heater. For vent lengths greater than 5 ft. (1,52 m), a condensate collector and trap must be
installed.
Recommended vent/air intake terminal position
Terminals should be so positioned as to avoid products of combustion entering openings into buildings or
other flues or vents.
Figure 12
* For clearances not specified in ANSI Z223.1 / NFP A 54 or CGA-B149, please use clearances in accordance with
local installation codes and the requirements of the gas supplier .
** For other than Direct Vent Appliance, 4 feet (1.22 m) below or to side of opening; 1 foot (300 mm) above opening.