Danmini YA-300-GSM User Manual

Danmini YA-300-GSM User Manual

Security gsm alarm system

Advertisement

Security GSM Alarm System
1 System Introduction
Wireless GSM intelligent anti-theft electronic alarm system is an innovative wireless mobile intelligent
warner integrating GSM digital signal processing techniques and imported STC microprocessor, and a variety
of technologies including digital voice announcer, English SMS, learning code, etc.
In addition, this alarm system is highly automatic, giving automatic voice or SMS alert in the event of
emergency without intensive manual settings required. Features of stability, reliability, safety, and humanizing
control enable it to be widely used for alert in shops, convenience stores, offices, villa as well as residential
communities.
2 Function Introduction
4 wired and 6 wireless defence zones;
Can preset and store 6 voice phones and 3 message phones;
Remote two-way intercom,Built-in intercom speaker;
Telephone (mobile phone) remote control programming;
SMS remote control preset & arm/disarm the main panel;
SMS alarm content can be changed;
3 groups of timely arm and disarm;
2 groups reply to timely control the home appliances open or close;
Can connect wireless siren(Option)
10-second automatic message recording;
Built-in intelligent English message;
Alarm locking memory and information clear for easy checking;
One-key-control function: Out Arm, Home Arm, Remote Arm;
Wireless intelligent learning encoding and comply additional accessories;
Arm, disarm, monitor and intercom by remote calling the alarm unit;
Real-time, delay, 24 hours, bypass defense zones programming function;
YA-300-GSM

USER MANUAL

Advertisement

Table of Contents
loading

Summary of Contents for Danmini YA-300-GSM

  • Page 1: User Manual

    Security GSM Alarm System YA-300-GSM USER MANUAL 1 System Introduction Wireless GSM intelligent anti-theft electronic alarm system is an innovative wireless mobile intelligent warner integrating GSM digital signal processing techniques and imported STC microprocessor, and a variety of technologies including digital voice announcer, English SMS, learning code, etc.
  • Page 2  Built in NI-HI rechargeable battery is available to provide power supply nearly 5hours automatically after power off;  AC and DC dual use are available for 24-hours-a-day normal guard;  Main unit anti-tamper and low-voltage detecting function. 3 Technical Parameter Input Voltage: DC9V~12V Standby Current:...
  • Page 3: Main Unit Settings

    Control Panel of Main Unit: ① Power hole ② Alarm output end ③ +12V power output or in ④ NO C Relay output ⑤ A Spare ⑥ Grounding wire (3-6) ⑦ SIM card slot ⑧ Setting button ⑨ Backup power switch ⑩...
  • Page 4 Arm indicator Always on Arm status Slow flickering Settings status/At home status Fast flickering Alarming status 3 seconds shiny look Home network successfully, and normal standby Lights Flicker Are registered or not installed SIM card network Extinguish System failure  Power-on for the First Time Following the method of installation, install the SIM card of main unit, make wired connection and fit the GSM antenna properly in order.
  • Page 5  Code Pairing by Remote Control Code Pairing of Remote Control In the status of disarm, enter settings and press [Set] once again, the main unit emits a short “ trigger remote controller ” and all the indicators of the defence zone are always on, which indicate that the unit enters remote control code pairing status;...
  • Page 6: Remote Control Programming

    main unit emits a long “ delete finished ”, and the indicator of defence zone 1 goes out. Code pairing for defence zone 1 is deleted successfully. 7 Remote Control Programming All the programming of the main unit are completed by key operations on a phone or send SMS commands, which shall dial GSM card number of main unit first.
  • Page 7 [Program password] + [57] + Message Receiving Phone [57]~[59] 3 groups [phone number] + [#] Number Delete Message [Program password] + [57] + [#] [57]~[59] 3 groups [Program password] + Defence zone Programming Factory default: 1/1/0 [60]+[01~08]+[1~4]+[1~8]+[0/1]+[#] [Program password] + Stay in defence zone Factory default: 0 [61] + [01~08] + [0/1] + [#]...
  • Page 8 alarm-receiving phone numbers from the first group the sixth group. Phone Number Settings: Delete Phone Number: Illustration: “X” indicates the set voice alarm-receiving phone number; set 0755-88824002 to be the second voice call number. SMS Command: 888852075588824002# Delete the third group of voice call number. SMS Command: 888853# Message Receiving Phone Number When it is set to alert through message, the main unit will send alarm SMS to three phone numbers, (for...
  • Page 9 Notes: “A” indicates the number of defence zone; “B” indicates the type of defence zone; “C” indicates the location of alarm; “D” indicates if the siren sounds. A: Number of defence zone: [1~6] corresponds to defence zone 1 to defence zone 6 respectively. B: Type of defence zone: [1] real-time, [2] 40 seconds delay, [3] 24 hours a day, [4] bypass.
  • Page 10: Clock Setting

    Clock Setting ■ In setup status, use keypad to input [32], then input the two digits [AA] of the present hour (24-hour system), the two digits [BB] of the present minute, and finally enter [#] to confirm. You will hear a long beep and a voice prompt “setting finished”.
  • Page 11 confirm. You will hear a long beep and a voice prompt “setting finished”. Operating method: [AA][BB][CC][#] indicates: 45 means 1st home appliance open address, 47 means 2nd home appliance open address, BB indicates: the hour of the setting time CC indicates: the minute of the setting time For example: turn on the 2 home appliance at 3:35a.m.
  • Page 12 It means to clear the memory of alarm. After the main unit sounds alarm, all the indicators of the triggered defence zone will be on and locked. In the status of disarm, only repeating the operations to disarm the guard can eliminate the lock display of the alarmed defence zone;...
  • Page 13: Maintenance

    [7] key: Open 2nd home appliance. [8] key: Close 2nd home appliance. [9] key: Open mini siren or wireless siren. If need to close siren, press any one of 1/2/3/4 keys. SMS command: 1234 [1-9] # ■ Home Appliance Control Home Appliance Switch Pairing:Home appliance switch can only accept the alarm unit signal control after paired.
  • Page 14 System Test Although the alarm system is used everyday, periodical maintenance and test are required to assure that it can run stably, reliably and safely. Usually thorough test must be performed on the alarm main unit every three months. You’d better check the sensor once a month; if not permitted by conditions, you shall check it at least every three months.
  • Page 15: Standard Package

    Do not drop this product on the ground or on hard objects, as it may lead to massive impact to cause faults and damage. Without approval and consent of relevant authorities, please do not set “999”, “110” or the alarm phone number of police station for this main unit.

Table of Contents