General Lubrication; Check Tire Pressure - Ariens SNO-THRO 924505 - 1332 Owner's/Operator's Manual

Ariens snow blower user manual
Hide thumbs Also See for SNO-THRO 924505 - 1332:
Table of Contents

Advertisement

CHECK CLUTCHES
Auger / impeller must stop within 5 seconds
when attachment clutch/impeller brake lever is
released.
Wheels must stop quickly when traction drive
clutch lever is released.
If clutches do not engage or disengage
properly, adjust or repair before operation (see
Service and Adjustments).
CLEAN ENGINE
Refer to Engine Manual for detailed
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked
every 5 hours of operation. Oil level MUST be
maintained in safe operating range on dipstick
at all times or engine damage will result (See
Engine Manual).
Park unit on a level surface. Refer to Engine
Manual for detailed instructions.
CHANGE ENGINE OIL
Change oil after first 2 hours of operation,
thereafter change oil every 25 hours (more
often if required). Refer to Engine Manual for
detailed instructions.
Run engine just prior to changing oil. Warm oil
will flow more freely and carry away more
contamination.

CHECK TIRE PRESSURE

Keep tires at pressure listed on the tire
sidewall.
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be
maintained.
Gear cases are filled to the correct level at the
factory. Unless there is evidence of leakage,
no additional lubricant should be required.
Check oil level each season or every 25 hours
of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 9). Lubricant
must be at least up to bottom of lubricant
filler hole with unit resting on a level-
surface.
2. Add lubricant if required. Allow oil to drain
to level of plug and replace plug.
IMPORTANT: Use only Ariens special gear
lubricant L-2 (Part Number 00008000).
1
1. Auger Gearcase - Cast Iron
2. Oil Fill and Drain Plug
3. Auger Gearcase - Aluminum

GENERAL LUBRICATION

IMPORTANT: Wipe each fitting clean before
and after lubrication.
IMPORTANT: DO NOT allow grease or oil to
get on friction disc, friction plate or belts.
NOTE: Apply Stens Mix Hi-Temp Grease or
equivalent to the lubrication fittings. See
Service Parts.
Sno-Thro should be lubricated (Figure 10) at
beginning of season or every 25 operating
hours.
Auger Shaft
NOTE: To grease auger shaft, remove shear
bolt nuts, and shear bolts. Turn auger on shaft
while applying grease at zerk fittings. Replace
shear bolt per instructions in Service and
Adjustments.
GB - 20
2
3
Figure 9
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents