INSTALLATION MANUAL SAFERA Siro R-line stove guard Power control units: PCU3 PCU3-W PCU5.1-U PCU5.1-P 20812 V4.5.0 ENG SIRO R-LINE...
Page 2
Install and check the application accor- meant for household use: • Power Supply Ⓓ 3. Troubleshooting ding to the instructions. SAFERA is not • Power Control Unit Ⓒ liable for any damages or expenses caused • Traditional cast-iron cookers and hobs •...
Page 3
INSTALLATION - STEP 1/6 Mount the Sensor unit Install the Cental Unit Ⓐ on the wall above the cooktop and follow these dimensions: 200 mm Installation Width Cooker width Height Align the Sensor unit ±15 mm with the centre of Max.
Page 4
INSTALLATION - STEP 2/6 Mount the Power Control Unit Ⓒ. Install the Power Control Unit according to the following instructions. PCU3 PCU5.1-U Fixed 3-phase connection. Fixed 1-phase connection. See pages 8-9. See pages 12-13. PCU3-W PCU5.1-P Perilex-connectors. 3-pin plug. See pages 10-11.
Page 5
Installation PCU3 - INSTALLATION Fixed 3-phase connection. Remove the fuses to the cooker and oven. Mount the power control unit Ⓒ on the wall behind the cooker or into the cabinet next to the cooker. Couple the protective earth first (PE).
Page 6
Installation PCU3-W - INSTALLATION 3-phase, Perilex-connectors. Remove the fuses to the cooker and oven. Mount the power control unit Ⓒ on the wall behind the cooker or into the cabinet next to the cooker. Install the power control unit Ⓒ with Perilex-connectors.
Page 7
Installation PCU5.1-U - INSTALLATION Fixed 1-phase connection. Remove the fuses to the cooker and oven. Mount the power control unit Ⓒ on the wall behind the cooker or into the cabinet next to the cooker. Couple the protective earth first (PE). Couple the other wires.
Page 8
PCU5.1-P - INSTALLATION 3-pin plug. 230V MAX. 25A MICRO DISCONNECTION 59-79 mm 73 mm 60 mm 68-80 mm ѥ WARNING ⚐ ATTENTION Connect the stove with Make sure that there is no power supply to Install the power control unit Ⓒ so that it 3-pin plug.
Page 9
INSTALLATION - STEP 3/6 INSTALLATION - STEP 4/6 Set up the wireless connection Calibrate the system Connect the power supply Ⓓ to the When the indicator light panels ❽ start blinking yellow-green, you need to calibrate Sensor unit Ⓐ: indicator light panels the system.
Page 10
INSTALLATION - STEP 5/6 Adjust the alarm limit Check closest When you adjust the Installation Alarm Limit Color of the indicator Number of Location of the Cooker Alarm Limit recommended alarm alarm limit, the new Height (1-12) light panels ❽ beeps limit from the refe- alarm limit is indica-...
Page 11
INSTALLATION - STEP 6/6 Check-list 3. INSTALLATION TROUBLESHOOTING Check the working order of the appliance and fill in the installation checklist: Problem Remedy Installation is not proceeding You can re-start the installation process anytime by as expected. pressing the adjustment mode button ❼ for five seconds until you hear the signal and continue from step 3/6.
Page 12
4. INSTALLING THE WATER LEAKAGE SENSOR (optional) Stove Guard can be equipped with max. four SAFERA Water Leakage Sensors. The sensors are placed in the typical leakage areas, e.g. under the dishwasher or sink. Attach the sensors Ⓕ in place.