Back-UPS (VA):
Back-UPS PRO (VA):
STEP 1:
Connect the UPS's Internal batteries (Figure 1):
NOTE: Battery Disconnect/Connector may vary or be
omitted on some models. Figure 1 illustrates some of the
variations in connectors. Please follow the illustration
which best resembles your UPS.
Procedure for Figure 1: (1, 2)
1.1 Remove the two screws holding the battery door.
1.2 Lay the UPS on its side and open the door
1.3 Gently pull the battery out.
1.4 Connect the two wires to the battery
NOTE: Make sure to observe the polarity (Red-to-Red, Black-to-Black)
NOTE: Small sparks at the battery connections are normal.
1.5 Insert the battery in the UPS. Carefully avoid pinching the wires.
1.6 Close the battery compartment door and replace the screws.
Procedure for Figure 1: (A)
1.1 Locate the 'Battery Disconnect' on the rear panel of the UPS. It is typically
a Yellow connector.
1.2 If the Battery Disconnect has a metal cover, remove the fastening screws
and move the cover
A
1.3 Press the yellow connector into the Battery Jack. A snap will be felt as the
connector partially engages the jack. A second snap will be felt as the
connector securely seats in the Battery Jack.
STEP 2:
Connect wiring & charge UPS (Figure 2):
NOTE: Ensure equipment is turned off.
2.1 Connect equipment to UPS
2.2 Connect UPS Power Cord to a suitable power receptacle
2.3 Reset the UPS Circuit Breaker by pushing-in the button
(Circuit breakers may differ on some models)
2.4 Power-up the UPS by pressing the
Switch.
2.5 Wait for the Self-Test to complete, then Power-up equipment.
2.6 Allow UPS to charge batteries for 24 hours prior to operating
on battery or performing additional Self-Test or Calibration
tests.
C B M _ O T Q G _ B U 3 _ 2 0 1 1 0 8 0 9 V 0 2
250, 280, 300, 400, 420, 450, 500, 600, 650
650, 1000, 1100, 1400
1
2
OR
1
2
3
button or
1
OR
1
1
2
A
Figure 1
2
3
Figure 2
Page 1

Advertisement

loading

Summary of Contents for CBM 250

  • Page 1 Back-UPS (VA): 250, 280, 300, 400, 420, 450, 500, 600, 650 Back-UPS PRO (VA): 650, 1000, 1100, 1400 STEP 1: Connect the UPS’s Internal batteries (Figure 1): NOTE: Battery Disconnect/Connector may vary or be omitted on some models. Figure 1 illustrates some of the variations in connectors.
  • Page 2 UPS Front Panel (Figure 3): NOTE: Symbols & functions may differ on some UPS models. Figure 4 illustrates some of the variations in displays. Please use the illustration which best resembles your UPS. Figure 3 ONLINE - UPS is supplying utility power to the POWER ‘ON/OFF’...
  • Page 3 UPS troubleshooting: NOTE: Troubleshooting procedures may differ depending on UPS model. Back-UPS troubleshooting Problem: Solution: UPS will not turn on (lamp within power I/O switch is not illuminated), but beeps when power I/O switch is on  Line cord plug is loose. Check fitting of line cord plug.
  • Page 4 For the complete User Manual or comprehensive troubleshooting, please visit the following websites: APC: http://www.apc.com or CBM: http://www.buyupsonline.com C B M _ O T Q G _ B U 3 _ 2 0 1 1 0 8 0 9 V 0 2...

This manual is also suitable for:

400420300280450500 ... Show all