Motorola HT Series Service Manual page 98

Professional series two-way portable radios
Hide thumbs Also See for HT Series:
Table of Contents

Advertisement

8-8
If the error code
displayed is ...
No Display
For LTR Models
If the error code
displayed is ...
ESN BAD
AppCode Fail
EER: Watchdog
Unprogrammed
ERROR: NO PTG
Backdoor
Table 8-2. Power Up Self-Test Error Codes (Continued)
Then, there is
a ...
improperly connected
display module or
damaged display
module.
:
Table 8-3. Power Up Self-Test Error Codes (LTR Models)
Then, there is
a ...
defective PTCB
defective PTCB
firmware
firmware failure
programming error
no primary talk group
---
Maintenance: Power Up Self-Test Error Codes
To correct the problem ...
check connection between main board and display module or
replace with new display module.
To correct the problem ...
return to factory for PTCB replacement.
reflash PTCB firmware.
restart radio
use CPS to properly program radio and PTCB.
use CPS to program zone with a Primary Talk Group.
turn radio off and restart.

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Mtx seriesPro series

Table of Contents