Installation Tips The sensor must not have The sensor must be firmly The sensor must not be The sensor must not have any fluorescent lighting in placed directly behind a fastened to prevent any object likely to move its sensing field. vibration.
Mechanical Installation Opening the Microwave Motion Sensor (MSS) From behind, before installation From the front, after installation Mounting the MMS Paste the template at desired Insert screws but do not screw Optional cable routing: location. them fully in. Notch the cover as shown in the picture.
Mechanical Adjustments THE WIDTH OF THE SENSING FIELD IS DETERMINED BY THE CHOICE OF THE PLANAR ANTENNA (OPTION) 6.4’ 3.2’ 3.2’ 6.4’ 3.2’ 6.4’ Wide sensing field: Narrow sensing field: 3-element antenna 6-element antenna 9.6’ 3-Element 6-Element Antenna Antenna SENSING FIELDS ACCORDING TO THE TYPE OF ANTENNA The sensing fields above correspond to the following adjustments:...
Page 5
6.4’ 3.2’ 3.2’ 6.4’ 3-Element Antenna 70º 6-Element Antenna For ceiling mounting, the vertical tilt angle of SENSING FIELDS – CEILING MOUNT the antenna must be set at the maximum The sensing fields above correspond to position of 70-75° and the spherical part of the following adjustments: the sensor must be oriented in the opposite Vertical angle of antenna: 70º...
The MMS is factory preset with the MTF ON. MTF is recommended for use in short vest bule areas to help reduce unwanted door hold-open time. Refer to the Programming Guide to alter this setting. LCN recommends keeping the MTF enabled for all applications. The detection capabilities perform as follows: BI-DIRECTIONAL MODE: •...
Sensitivity Relay Hold Time Relay hold time refers to the hold time on the 0 = Minimum Sensitivity output relay of the Eagle. Values range from 0 to 9 = Maximum Sensitivity Default: 8 0 = .5 sec. 1 = 1 sec through 9 = 9 sec in 1 second intervals Detection Mode Default: 0 Detection mode offers 3 different levels of...
Company Contact Do not leave problems unresolved. If a satisfactory cannot be achieved after troubleshooting a problem, please contact LCN at 1-800-526-2400. If you must wait for the following workday to call, leave the door inoperable until satisfactory repairs can be made. Never sacrifice the safe operation of the automatic door or gate for an incomplete solution.