The stainless steel cylinder gives longevity of service and also less maintenance because there is no sacrificial anode. The Everlast™ Series 2000 Electric Water Heater will provide continuous hot water for many years to come. Features of your Everlast™ Water Heater The Everlast™...
Page 3
Pressure and temperature relief valve (P&T) The Everlast™ Series 2000 is fitted with an 850 kPa P&T valve, which is located on the side of the water heater and is essential for its safe operation.
Figure 2. Whilst this is necessary to ensure that the sheetmetal base of conventional water heaters does not corrode; wet conditions do not effect the Everlast™ polymeric casing which is corrosion proof. A base pad is optional and will ensure even support. There is no need for any external weather protection for your Everlast™...
The Everlast™ Series 2000 water heater is designed to ensure total drainage for flushing if required. It is recommended that a drain cock be installed on the cold water inlet pipe adjacent to the heater to facilitate flushing annually in poor water quality areas.
Pressure Limiting Valve set to 500 kPa. Hot Water Outlet 3/4 " BSP The Pressure & Temperature Relief Valve supplied with the Series 2000 is set at 850 kPa and 99 C. The Expansion Control Valve if required by some ottom Element 3/4 "...
Page 7
* Solar thermostats are designed for auto-reset and the Solar Installation, or Solar panel retrofit to existing installation, will include thermostatic bypass in the solar panel return piping design to ensure that thermal cut-out does not operate in normal use. EVERLAST MANUAL 16pp.indd 7 9/07/10 11:02 AM...
Page 8
EVERLAST HYDRO SYSTEMS SINGLE ELEMENT WIRING PLAN SERIES 2000 MODEL 160S, 250S & 315S TESTING: There is no circuit switching in the Single Element Models. The testing is limited to the Circuit Continuity Test across the element which should indicate an element resistance of approx.
Page 9
TOP ELEMENT 4.8 KW BOTTOM THERMOSTAT SET AT 70 C EWT1L2-5085 FOUR TERMINALS BOTTOM ELEMENT 4.8 KW ACTIVE ACTIVE NEUTRAL TOP RED BOTTOM RED BLACK GD or O/P O/P Main Common BOOST TERMINAL CONNECTOR EVERLAST MANUAL 16pp.indd 9 9/07/10 11:02 AM...
Electrical Connection The Everlast™ Series 2000 water heater is designed for single phase 240 V. A.C. supply only. Australian Standard AS 3000 – (Wiring Code), and local supply authority regulations apply. Electrical safety requirements of AS/NZS 60335 apply. The Wiring Plans shown at Figure 3 and 4 indicate the correct connection for single and twin element water heaters.
Flushing and Draining: To flush or to drain the Everlast™ Series 2000 water heater, power must be turned off and then turn off the cold water supply to the water heater. The lever on the pressure and temperature relief valve should be opened but care should be taken so the lever does not snap back as it could damage the valve seat.
Everlast™ accredited Service Agent’s premises will be charged to the owner. EVERLAST ™ Hydro Systems is excluded to the extent allowable by law from responsibility for any consequential loss including; injury to persons, injury to property, economic loss, pain and suffering or legal or other damages flowing from any manufacturing fault/defect.
Page 13
*Where the heater is installed outside the boundaries of a Capital Cities Metropolitan area i.e. those areas STD, the cost of transport, insurance and travelling between the nearest Everlast accredited Service Agent’s premises will be charged to the owner. Printed May 2012 Product Code number: 44953 EVERLAST MANUAL 16pp.indd 13...
Page 14
Address ________________________________________________________________ Town/Suburb__________________________State____________Postcode ___________ Electrician____________________________________Licence No. _________________ Address ________________________________________________________________ Town/Suburb__________________________State____________Postcode ___________ EVERLAST™ HYDRO SYSTEMS PTY LTD. 14 COMMERCIAL DRIVE, DANDENONG. VIC 3175 PH (03) 9768 2404 FAX (03) 9768 2406 www.everlastwaterheaters.com everlasthydro@everlastwaterheaters.com ACN 087 168 116 (A MEMBER OF THE CHB GROUP OF COMPANIES ) EVERLAST MANUAL 16pp.indd 14...
Page 15
Electrician___________________________________Licence No. ______________ Address ______________________________________________________________ Town/Suburb_____________________________State________Postcode _________ Installation Date _________________________ RETURN TO : EVERLAST™ HYDRO SYSTEMS PTY LTD. 14 COMMERCIAL DRIVE, DANDENONG. VIC 3176 PH (03) 9768 2404 FAX (03) 9768 2406 www.everlastwaterheaters.com everlasthydro@everlastwaterheaters.com ACN 087 168 116 (A MEMBER OF THE CHB GROUP OF COMPANIES ) EVERLAST MANUAL 16pp.indd 15...
Need help?
Do you have a question about the series 2000 and is the answer not in the manual?
Questions and answers