Les foyers DON-BAR Fireplaces CFS series Installation, Operation And Maintenance Manual

Advertisement

Quick Links

Installation, Operation
and Maintenance Manual
LES FOYERS
DON-BAR
FIREPLACES
Série
CFS
CFS SERIES
WOOD STOVES
Les foyers DON-BAR Fireplaces, inc.
Shop and Showroom: 741, St-Vallier Ouest, Quebec (Quebec) G1N 1E2
Phone: (418) 686-9114 - Fax: (418) 686-9117
Website: www.don-bar.com - Email: don-bar@don-bar.com
REV. 2010-01

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFS series and is the answer not in the manual?

Questions and answers

Summary of Contents for Les foyers DON-BAR Fireplaces CFS series

  • Page 1 Maintenance Manual LES FOYERS DON-BAR FIREPLACES Série CFS SERIES WOOD STOVES Les foyers DON-BAR Fireplaces, inc. Shop and Showroom: 741, St-Vallier Ouest, Quebec (Quebec) G1N 1E2 Phone: (418) 686-9114 - Fax: (418) 686-9117 Website: www.don-bar.com - Email: don-bar@don-bar.com REV. 2010-01...
  • Page 2: Table Of Contents

    LES FOYERS DON-BAR FIREPLACES Installation, Operation, and Maintenance Manual The manual is divided into 5 parts: Page 3 PART 1: Installation ..........Page 11 PART 2: Security, Operation and Maintenance ... Page 18 PART 3: Parts List ..........Page 19 PART 4: Chimney Fires ..........
  • Page 3: Part 1: Installation

    PART 1: INSTALLATION 1. Important notice 8. Floor protection installation 8.1 Non-combustible floor protection 8.2 Removing the existing resilient flooring 2. Listed chimneys 2.1 Approved chimneys 9. Optional accessories installation 3. Before beginning the 9.1 Anti-smoke flap installation installation 9.2 Humidifier tray 3.1 Choosing the best location 9.3 Removable ash shelf 3.1.1 Chimney...
  • Page 4: Part 1: Installation

    PART 1: INSTALLATION Typical installation with a ceiling outlet 1. IMPORTANT NOTICE WARNING: Any modification, change, or substitution of any fireplace component and/or not following the installation, operation, and maintenance instructions will void the warranty and can put your security at risk. Round top Factory-built insulated...
  • Page 5 4. Before beginning the installation Typical nstallation with a wall outlet Before 3.1 Choosing the best location: beginning the installation, make sure the spot you Factory-built have in mind for the fireplace and the chimney insulated chimney meet the following requirements: 2100 degrees See Pages 9 and 10 for diameters...
  • Page 6 5. Factory-built chimney installation Chimney minimum height above the roof 5.1 Ceiling (or wall) support installation: Use and install only parts furnished by the manufacturer of the chimney. 10 feet (3 m) Radius Chimney lengths installation: Continue with the installation of the chimney by positioning lengths with the male end up.
  • Page 7 7.2 Telescopic duct installation: Fix the duct to Stove pipe minimum the back of the fireplace as shown in Drawing 5. clearances 18" (460 mm) If necessary, if the warm air outlet in the from ceiling basement is not in line with the telescopic duct, 9"...
  • Page 8 Protection for combustible 8.2 Removing the existing resilient flooring: floors Prior to installing the floor protection, remove any existing resilient flooring. (carpet, etc.) 9. Installation of optional accessories 8" (200 mm) minimum 9.1 Anti-smoke flap (optional): For installation 18" (460 mm) details, see Drawing 27.
  • Page 9: Floor Protection

    50-80 60-90 69-61 69-69 69-80 80-60 80-69 20-1/2” 23-1/2” 27-1/4” 27-1/4” 27-1/4” 31-1/2” 31-1/2” 48-1/4” 1226 1226 1226 48-1/4” 48-1/4” 1226 48-1/4” 1226 48-1/4” 1226 48-1/4” 1226 48-1/4” 13” 16” 19-3/4” 19-3/4” 19-3/4” 24” 24” 19-3/4” 24” 13” 19-3/4” 19-3/4” 16”...
  • Page 10 CFS-R 69-61 CFR-S 69-69 CFR-S 80-69 CFR-S 27-1/4” 27-1/4” 31-1/2” 48-1/4” 1226 1226 48-1/4” 48-1/4” 1226 19-3/4” 19-3/4” 24” 19-3/4” 13” 16” 20-3/4” 20-3/4” 22-3/4” 6-7/8” 6-7/8” 6-7/8” 14” 17” 14” Outlet 8" Outlet 8" Outlet 8" reducible reducible reducible to 7"...
  • Page 11: Part 2: Security, Operation And Maintenance

    PART 2: SECURITY, OPERATION AND MAINTENANCE 1. General operation 8. BBQ installation 1.1 Combustion control 8.1 BBQ grill installation 1.2 Air intake control 1.3 Smoke outlet control 9. Chimney maintenance 1.4 Danger of burns 9.1 Creosote build-up and removing 9.2 Inspection and regular maintenance 2.
  • Page 12 PART 2: SECURITY, OPERATION AND MAINTENANCE 1. General operation Using the removable handle to control the air intake 1.1 Combustion control: Two valves are used to control combustion. The first one (Drawing 20), controls the air intake in the combustion chamber.
  • Page 13 supply to maintain the combustion. If the room is Using the handle to control the under a negative pressure, if the house is too HE sliding smoke deflector airtight, or if a ventilation device is in operation it may be necessary to open a door or a window to Open fully the smoke damper Close the smoke damper to start a fire or when making...
  • Page 14 the air intake control must be fully open. Always Recommended wood species: For an use a firescreen with an open fire. Note that the efficient and economical operation, use only dry air intake control is inoperative when the door is hardwood such as maple, oak, wild cherry, birch, open.
  • Page 15 4.7 Forbidden flammable liquids: Never use 6. Fireplace maintenance and flammable liquids or accelerators such as gas, protection lamp oil, kerosene, BBQ starters, or other flammable substances to start or stir up a fire. Always keep these products away from the fire Finish maintenance: Your fireplace is when using the fireplace.
  • Page 16: Anti-Smoke Flap Installation

    Soot build-up on the HE smoke sliding Cleaning of the HE smoke deflector deflector (Drawing 26): During the chimney cleaning, be sure to remove any creosote or soot To prevent soot build-up the build-up over the HE smoke deflector. The build- smoke deflector must be up of soot on the deflector can prevent the flow of cleaned at regular intervals...
  • Page 17: Part 3: Parts List

    PART 3: REPLACEMENT PARTS LIST To order a part: 1) Check the replacement part required 2) Specify the year of the fireplace installation _________________ 3) Fax this list with your coordinates to 418-686-9117 HE Combustion System Sliding damper Deflector (without the sliding damper) Rod and plate assembly for the sliding damper Chimney adaptor Standard Parts...
  • Page 18: Part 4: Chimney Fires

    PART 4: CHIMNEY FIRES DIRECTIVES IN CASE OF A CHIMNEY FIRE How to detect a chimney fire What to do - Odour: Smell of smoke in the air. - Immediately alert the occupants of the building about - Sight: The colour of the pipe change. Flames at the potential danger.
  • Page 19: Part 5: Warranty

    LES FOYERS DON-BAR 25 YEAR LIMITED WARRANTY FIREPLACES 1. The first 5 years: If, during this 5- year period, and in the course of a normal 1.4 Gaskets: Fireplace gaskets are 8. The duration of the warranty on any use, a component part of the fireplace warranted for 90 days following the part that is the object of a claim must becomes defective due to a material or...