Gas category II 2E+ 3+ Expansion vessel net capacity 5.4 l Expansion vessel initial pressure 0.7 bar Nominal gas flow rate at 15°C and 1013 mbar BRITONY System II 80 BRITONY System II 100 Maximum Minimum Maximum Minimum power kW...
Pump and expanssion vessel characteristics PUMP HEAD AVAILABLE Pression disponible Minimum flow rate (with all heating thermostatic valves closed) Débit mini (robinets thermostatiques fermés) m CE Flow Débit 1000 1100 1 = by-pass closed 2 = by-pass open Note : The system initial pressure should be over the following value : System static height (in metre) + 0.7 = Initial pressure (in bar) Head available / flow Components location...
FUNCTIONING COMPONENTS LOCATION Switching on 1) Check that the gas service tap is opened at the gasmeter and main power is on. 2) Check that pressure in central heating system is above 0.7 bar and below 2.5 bar with the pressure gauge 3) Open the gas tap 3 by turning from right to left.
Central Heating It is possible to override the 3 minute delay by pressing the To be able to supply heating, the main switch 15 must be RESET button 23 turned fully clockwise to position. This will be confirmed by the green indicator light Lock out procedure When there is a demand for heating (either from the room Flame disappearance :...
ELECTRICAL WIRING continuation ADJUSTMENTS ON CONTROL PCB N° Designation Wiring colours The following adjustments are available on the regulation PCB. To -Overheat sensor Brown gain access to them, pivot down electrical box, remove the rear -Electrical box cover and the rear panel of electrical box, unplug connectors from 14a.
REMOVAL AND REPLACEMENT OF PARTS Before removing appliance case, isolate 5. Ignition Electrodes 10. Pressure Switch the gas and electrical supplies. Isolate boil- Carry out steps 1 and 2 as above. Hinge Remove outer case and sealed chamber er from the system and drain before down electrical box by pressing retaining front panel as in steps 1 and 2.
Page 7
14. Flow switch 20. Thermistor Drain boiler as in step 12. Disconnect the Drain the boiler as step 12. Disconnect the plug, remove the retaining clip pull the electrical plug, turn the top cover anti- thermistor out. Reassemble in reverse order. clockwise, remove the O-ring and the 37 = Heating thermistor brass piston.
Page 12
This appliance is suitable for Natural gas or LPG. A gas conversion must be made by a competent person. Chaffoteaux & Maury are continuously improving their products and therefore reserve the right to change specifications without prior notice and accepts no liability for any errors or omission in the information contained in this document. Manufacturer: Chaffoteaux &...