"APOLLO" control panel manufactured, by SIGMA SECURITY is a
modern, state of the art, security system which can cover the security
needs of a household, or an office. It has been designed to combine
easiness of use and the best possible security.
In this manual is described in detail, the use and operation of this
unit, so that you understand and take full advantage of its capabilities.
For any further questions, please contact the technician who has carried
out the installation of the system.
In order to better understand the settings and the operation of the
system, read carefully the explanation of the main terms, which you will
find in this manual.
ZONE: it is a specific region of the protected area, which can be
protected by magnetic contacts, P.I.R. detectors, Glass Break detector
etc. Furthermore, smoke, gas or humidity detectors can be connected
in a single or various zones. Zones, depending on their mode of
operation, may be characterized as:
Internal: these zones are bypassed when you activate home arming.
(Arming the system, while, you stay in the house).
Perimeter: these zones are armed, if the panel is armed, regardless
the arming mode of the panel (HOME, or AWAY). These zones may
be bypassed.
24 hours: these zones are always armed, regardless the condition of
the panel (wether the panel is armed or disarmed).
BYPASS: is the operation by which you temporarily deactivate any
zone(s), while you arm the system.
Code: It is the 4-digit, 5-digit, or 6-digit number, which you must use
for arming, disarming and user programming of the system.
Automatic Arming and Disarming: is the capability of the system
to automatically arm and disarm at a specific time and day(s), of the
week.
Quick Arming: is the arming of the system by using only a single
digit number and [ENTER], instead of the entire code.
Partitions: is the capability of the system to operate at two different
partitions (fully independent subsystems).
APOLLO
SIGMA "APOLLO"
User Manual
Page 1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Apollo and is the answer not in the manual?

Questions and answers

Summary of Contents for Sigma Apollo

  • Page 1 SIGMA "APOLLO" “APOLLO" control panel manufactured, by SIGMA SECURITY is a modern, state of the art, security system which can cover the security needs of a household, or an office. It has been designed to combine easiness of use and the best possible security.
  • Page 2: Indications And Use Of The Keypad

    16 keys. In every keypad you have the indication of the partition it belongs to. You may change partitions, using a valid code. This operation is described in the relative chapter of this book. Page 2 User Manual APOLLO...
  • Page 3: Indication Led's

    It turns on if a delay zone is unbalanced or if a key is pressed. The illumination LED's also turn off if within 1 minute, no key is pressed. KEYS • 0 - 9: Numeric keys. They are used to enter numbers, during arming, APOLLO User Manual Page 3...
  • Page 4: Programming The System

    CODE] & [ENTER]. The dot on the LED Display will start blinking to indicate the panel is in programming mode. The main user code is 1777. This code must be changed using the CODE editing procedure. Page 4 User Manual APOLLO...
  • Page 5 PARTITION MAIN CODE: Arms and disarms the partition (partition) to which it belongs and the partitions it has access to. It sets up or deletes the codes, cards and remote controls that belong to its partition. Furthermore, it APOLLO User Manual Page 5...
  • Page 6: Programming, Editing, Deleting Codes

    The panel will report the quick arming to the Central Station. Press, [CODE] [9] [8] [Χ]. [Χ]=[0-9], is the quick arming number. Only main user code can program the quick arming number. This function is disabled in factory default programming. Page 6 User Manual APOLLO...
  • Page 7: Programming Date And Time

    [ENTER]. [D] is the number corresponding to the current day of the week (1-7). For Sunday press 1, for Monday press 2, for Tuesday press 3, e.t.c. When you press the relative key the relative LED of the day will turn APOLLO User Manual Page 7...
  • Page 8: Programming The Date

    [TIME] [4] [H] [H] [M] [M], for partition A. [TIME] [7] [H] [H] [M] [M], for partition B. To read auto arm time, press: [READ] [TIME] [4], for partition A. [READ] [TIME] [7], for partition B. To cancel auto arm time, press: Page 8 User Manual APOLLO...
  • Page 9 (date) and also the LEDs of the days of the week that the system will automatically disarm, will turn on. For Sunday the Led 1 will turn on, for Monday the Led 2, for Tuesday the Led 3, e.t.c. Every time you press a APOLLO User Manual Page 9...
  • Page 10 NOTE: This function may be programmed only by main user code (01) using the system keypad, and not by the downloading software. PROGRAMMING THE "FOLLOW ME" TELEPHONE NUMBER The main user code may be used to program , edit or delete the Page 10 User Manual APOLLO...
  • Page 11: Exit User Programming

    (telephone line failure, low battery voltage e.tc.). The LED "TROUBLE" will turn off when the system is armed. If there is a problem call the installer so he may perform maintenance. APOLLO User Manual Page 11...
  • Page 12 “ΒΥPASS” will start blinking. Enter the numbers of the zones you wish to bypass (e.g. 01, 03, 08, 12, e.t.c.) and then press [ENTER]. The system will arm, while the bypassed zones LED’s will blink during the exit Page 12 User Manual APOLLO...
  • Page 13 To bypass certain zones, which are common in both partitions, you must bypass them at each partition separately. • The zones that will be bypassed, with the above mentioned method, will automatically return to normal operation mode, when the system disarms. APOLLO User Manual Page 13...
  • Page 14 [BYPASS] [BYPASS]. The keypad buzzer will sound for confirmation, and the LED “BYPASS” will turn off. The zones that have been bypassed using the above, mentioned method, will automatically return to normal operation mode, when the system disarms. Page 14 User Manual APOLLO...
  • Page 15: Disarming The System

    All delay zones will operate as instant, and all interior zones are bypassed. 2. The following arming method is active only if, the installer has programmed the system to perform auto home arming. APOLLO User Manual Page 15...
  • Page 16: Cancel An Alarm

    LED “ARM” will change status. CANCEL AN ALARM To cancel an alarm enter [USER CODE] and press [ENTER]. The sirens of the system will be silenced, and the digital communicator will report to the Centarl Station. Page 16 User Manual APOLLO...
  • Page 17 NOTE: During auto arming the system is fully armed. If after the end of exit delay any zones are unbalanced they will be automatically bypassed. CHIME OPERATION If you wish to be notified when a door or window in your premices APOLLO User Manual Page 17...
  • Page 18: Displaying The Current Time

    In case the system operates in two partitions, the operation of every partition is the same as described in a simple installation. Following you will find abilities and functions of the system while operating in two partitions. Page 18 User Manual APOLLO...
  • Page 19 In case the system operates in 2 Partitions, you can arm or disarm any of them or both, at the same time. This is done using the following methods and a code that has the ability to arm or disarm both partitions. APOLLO User Manual Page 19...
  • Page 20 CODE] and press [ENTER]. The digital communicator will report to the Central Station. If the alarm was triggered by a fire zone, the siren sounds intermittently, and on the keypads the relative zone LED turns on. The Page 20 User Manual APOLLO...
  • Page 21: Trouble Table

    When a fire zone has a line fault, the keypad buzzer sounds intermittently. To silence the buzzer press any key. In case of telephone line failure, the keypad buzzer sounds continously. To silence the buzzer press any key. APOLLO User Manual Page 21...
  • Page 22: Maintenance

    [ENTER], so that you are certain that the sirens of the system operate properly. Test the battery voltage of the system, by pressing the [0] key for 2 seconds. On the LED display you will have the battery voltage. MAINTENANCE Page 22 User Manual APOLLO...
  • Page 23 • The replacement of the panel and siren’s batteries must take place every three years. APOLLO User Manual Page 23...
  • Page 24 W A R R A N T Y Sigma Security warrants its products hereinafter referred to as the “Product” or “Products” to be in conformance with its own plans and specifications and to be free of defects in materials and workmanship under normal use and service for a period of 24 months from the day of purchase from the Manufacturer.