Electrical Installation: Connections And I/O Signals - Schäfter+Kirchhoff SK22368GTOC-LA Instruction Manual

Color line scan camera 3x 7456 pixels, 4.7 µm x 4.7 µm, 120 / 60 mhz pixel frequency
Hide thumbs Also See for SK22368GTOC-LA:
Table of Contents

Advertisement

2.2 Electrical Installation: Connections and I/O Signals

For the SK22368GTOC-LA line scan camera data transfer and camera control is
provded by the Gigabit Ethernet interface 3 . Use a CAT6 twisted-pair cable to
connect the camera with a PC. The maximum cable length is 100 m.
The operating power has to be supplied by an external source into socket 1
If you want to operate the camera in FREE RUN trigger mode, the connection is
completed with the CAT6 Ethernet cable and the connection to an external power supply.
For any kind of synchronized operation the external trigger signal(s) have to be wired to socket 2 in addition.
A frame synchronization signal and two separate line synchronization signals can be handled. The various
trigger modes are particularly described in section Synchronization of the Imaging Procedure and the Object
Scan Velocity, p. 19
1
2
3
Accessories (see also Accessories and Spare Parts, p. 32):
Power Supply Unit PS051515
Input: 100-240 VAC, 0.8 A, 50/60 Hz, IEC 320 C14 coupler
(for IEC C13 power cord)
Output: +5V DC, 2.5 A / +15 V DC, 0.5 A / -15 V DC, 0.3 A
Cable length 1 m, with Lumberg connector KV60,
female 6-pin
(for power cable SK9015.x or SK9016.x)
Power Cable SK9015.x
Use this cable to feed external supply voltage into socket
Connectors:
Hirose plug HR10A, female 6 pin (camera side)
Lumberg SV60, male 6-pin connector (for supply voltage)
Length 1.5 m (standard) or 0.2 m
8
Power +5V, +15V
1
5
6
4
12
11
7
3
10
8
2
9
1
I/O Connector
2
TTL_Inx Specification
Data
3
RJ45 con nector for Gigabit Ethernet cable
Status indicators
Network connection speed
SK22368GTOC-LA Instruction Manual (11.2014)
Hirose series 10A, male 6-pin
Pin
4
3
1
5
2
2
6
1
3
Hirose series 10A, male 12-pin
5
4
3
6
4
5
12
11
3
7
6
1
10
8
2
9
1
Max. input frequency
Input voltage,
absolute max. range
Input voltage max. low
Input voltage min. high
Input current
off
no connection,
10 Mbyte/s connection, or
100 Mbyte/s connection
on
1 Gbyte/s connection
Network Cable CAT6.x
For connecting socket
interface. Both ends with RJ45 connectors.
External Synchronization Cable SK9024.x
Use this cable to feed external synchronization
signals into socket
.
1
Connectors:
Hirose plug HR10A, female 12 pin (camera side)
Phoenix 6 pin connector incl. terminal block (for
synchronization signals)
Length 3 m or 5 m. Other lengths on request.
2 Installation and Setup
!
Carry out the
software installation
prior to connecting
the network cable.
(see section 2.3 )
Signal
Pin
+15 V
4
+15 V
5
+5 V
6
Pin
Signal
1
GND
2
8
FrameSync IN
10
LineSync A IN
6
LineSync B IN
16.5 Mhz
min -0.5 V
max 7.0 V
Network activity
off
no connection
on
connected
flash
data is being
light
transmitted or
received
with the PC Ethernet
3
.
2
Schäfter + Kirchhoff GmbH • Hamburg
Signal
+5 V
GND
GND
0.99 V
2.31 V
10 µA
© 2014

Advertisement

Table of Contents
loading