Installation Guide
Sconce
(LF1-XX-XX-XX; All Finishes)
Application
Lightfalls by 3M™ + Todd Bracher (the "Product") is a decorative LED lighting system for dry, interior use.
Safety Information
Please read, understand and follow all safety information contained in this Installation Guide prior to the installation of these kits. Retain these instructions
at the installation site for future reference.
!
WARNING:
Indicates a potentially hazardous situation, which, if not avoided, could result in death or serious injury and/or property damage.
CAUTION:
!
Indicates a potentially hazardous situation, which, if not avoided, could result in minor or moderate injury and/or property damage.
To reduce risk associated with fire or electrical shock hazards:
• Electrical installation must be performed by a licensed electrician in accordance with NFPA and state or local electrical codes.
• Disconnect the power source before installing or servicing.
To reduce risk associated with fire:
• Only use the LED driver(s) provided by 3M.
To reduce risk associated with physical injury from the Product falling:
• The Lightfalls fixture can weigh up to 1 pounds/0.5 kilograms. Ensure that mounting brackets are adequately fastened to the load bearing point and
able to carry the required load. Always refer installation to a licensed electrician or certified lighting contractor.
• DO NOT use the Product if it has incurred any physical damage. Refer to a licensed electrician to check the Product before putting it into service.
To reduce risk associated with associated with environmental contamination:
• At the end of product life, dispose of electronic waste in accordance with applicable local and government regulations.
To reduce the risk associated with hot surface:
• Do not attempt to access and to touch the light fixture heat sink when it is operating.
LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014
EXPLANATION OF SIGNAL WORD CONSEQUENCES
WARNING
!
CAUTION
!
LIGHTFALLS by 3M™ + Todd Bracher
Sconce

Advertisement

Table of Contents
loading

Summary of Contents for 3M LIGHTFALLS

  • Page 1 To reduce risk associated with physical injury from the Product falling: • The Lightfalls fixture can weigh up to 1 pounds/0.5 kilograms. Ensure that mounting brackets are adequately fastened to the load bearing point and able to carry the required load. Always refer installation to a licensed electrician or certified lighting contractor.
  • Page 2: General Information

    Read Before Installing Be sure you have the most current Installation Guide. The information in this Installation Guide is subject to change. Call 3M at the above number, or go to www.3MArchitecturalMarkets.com/Lighting to obtain a current Installation Guide. The site should be inspected to ensure it has been adequately pre- pared for installation.
  • Page 3: Installation Overview

    Table B. DC Power Requirements (Varies Depending on Configuration) Model Description Max Input Typical Input Typical Input Current (A) Power (W) Voltage (V) LF1-XX 2 LEDs, each at half 0.45 16.2 power LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014 Page 3...
  • Page 4 Use provided harness to connect to LED assembly Dim– 0–10V Dimmer (such as Lutron Dim+ DIVA 0–10V Wire Nut dimmer) Figure 1: LF1 and LF-L3 Wiring Diagram Page 4 LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014...
  • Page 5 5. Install the Sconce Bracket to the anchor points with customer supplied screws (See Figure 3). Customer Supplied #6 Screws Screw Caps Sconce Bracket Figure 3: Sconce Bracket Installation LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014 Page 5...
  • Page 6 (See Figure 4). Figure 4: Wire Harness Connection 7. Position both Heatsink/LED Assemblies at the Sconce Bracket as shown (Figure 5). Figure 5: Heatsink/LED Assembly Position Page 6 LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014...
  • Page 7 Press with enough force to snap the reflector into place on the reflector standoff. To produce a different lighting effect, re-install the reflector rotated by 90°. Slots High Side Figure 7: Primary Reflector Installation LIGHTFALLS by 3M™ + Todd Bracher Installation Guide - Sconce, Rev. C, Feb. 2014 Page 7...
  • Page 8: Component Replacement

    LIGHTFALLS by 3M™ + Todd Bracher Sconce Before Energizing the Circuit Ensure that the cabling is secure, the connections are tight and the length of cable between the Lightfalls fixture and power unit is within the maximum for the gauge of wire used. Component Replacement Table C.
  • Page 9: Warranty Document

    Limited Warranty 1. When used in the Application, 3M warrants to the party who purchased the Product directly from 3M (the “Buyer”) that the Product will be free from defects in material and workmanship (the “3M Warranty”) for the applicable time period stated below (“Warranty Period”), which will begin on the earlier of: (a) Product installation date;...