Contents CB6 Gas Barbeque Part 1 Introduction ..................2 Part 2 Specifications ................. 3 Part 3 Installation ..................5 Part 4 Operation ..................7 Part 5 Cleaning and Maintenance ............8 Part 6 Gas Conversion ................10 Part 7 Replacement Parts List ..............14...
Part 1 Introduction We are confident that you will be delighted with your Cobra Series Barbeque, and it will become a most valued appliance in your commercial kitchen. To ensure you receive the utmost benefit from your new Cobra Appliance, there are two important things you can do.
Part 2 Specifications Model Covered in this Specification - - All Other Markets: CB6 GAS BARBEQUE. LP Gas / Butane General Input Rating 66.0 MJ/hr Supply Pressure 2.75 - 4.50 kPa A commercial heavy duty, fully modular, gas fired Burner Operating 2.60 kPa (*)
Page 6
Part 2 Specifications Dimensions GAS BARBEQUE (600mm)
18 m³/hr minimum. substances in the room, the appliance is installed in. LPG / Propane 18 m³/hr minimum. Cobra Series Barbeques are designed to provide 3. Position the appliance in its approximate years of satisfactory service and correct installation working position.
Page 8
5. Correctly locate the appliance into its final operating position and using a spirit level, adjust the legs so that the unit is level and at the 1. Cobra Model Barbeques do not require an correct height. electrical connection, they function totally on the gas supply only.
Pilot ignition can be viewed through openings in the plastic surround fitted to the piezo igniter button. 1. The Cobra Barbeques have been designed to 3. Hold in the gas control knob for approximately provide simplicity of operation and 100% safety 10-15 seconds, then release.
Part 5 Cleaning and Maintenance Weekly Cleaning AUTI ON NOTE: Always turn electrical supply at the mains supply before cleaning. Barbeque usage very high, This appliance is not water proof. recommend that the weekly cleaning procedure Do not use water jet spray to clean interior is carried out on a more frequent basis.
Page 11
Part 5 Cleaning and Maintenance c. To remove any discolouration, use an Periodic Maintenance approved stainless steel cleaner or stainless steel wool. Always rub in the direction of the NOTE: grain. All maintenance operations should only be carried out by a qualified service person. d.
Part 6 Gas Conversion Gas Conversion Procedure Pilot Burners AUTI ON 1. Disconnect the following:- Ensure that the Unit is isolated from the gas Gas supply tube to pilot burner. supply before commencing servicing. NOTE: These conversions should only be carried out by qualified persons.
Page 13
Part 6 Gas Conversion Gas Regulator - NAT Gas / LPG / Butane Only. NOTE, Pin rotated for Natural Gas NOTE, Pin rotated for LPG NOTE: The regulator supplied is convertible between Natural Gas and LP Gas, but it’s outlet pressure is fixed ex-factory and is NOT to be adjusted.
Page 14
Part 6 Gas Conversion Gas Specifications - Australia: Natural Gas LP Gas (Propane) Main Burner Injectors 2.70mm 1.65mm Pilot Burner Injectors 0.45 0.30 Low Fire Adjustment turns out (ccw) ½ turn out (ccw) Supply Pressure 1.13 - 3.40 kPa 2.75 - 4.50 kPa Burner Operating Pressure (*) 0.95 kPa (*) 2.6 kPa (*)
Page 15
Part 6 Gas Conversion - All Other Markets: Natural Gas Town Gas (**) Main Burner Injectors 2.70mm 4.50mm Pilot Burner Injectors 0.45 0.75 Low Fire Adjustment turns out (ccw) 2 turns out (ccw) Burner Operating Pressure (*) 0.95 kPa (*) 0.63 kPa (*) Main Burner Aeration Shutter Fully Open...
Part 7 Replacement Parts List Replacement Parts List IMPORTANT: Only genuine qualified replacement parts should be used for the servicing and repair of this appliance. The instructions supplied with the parts should be followed when replacing components. For further information and servicing instructions, contact your nearest qualified service branch (contact details are as shown on the reverse of the front cover of this manual).