easyRAID Q08+F2R2 Hardware User Manual

Fibre channel to serial ata ii disk array system

Advertisement

Quick Links

easyRAID Q08+F2R2
Hardware User Manual
42-30000-5074
Fibre Channel to Serial ATA II
Disk Array System
Version 1.0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Q08+F2R2 and is the answer not in the manual?

Questions and answers

Summary of Contents for easyRAID Q08+F2R2

  • Page 1 Q08+F2R2 Hardware User Manual 42-30000-5074 Fibre Channel to Serial ATA II Disk Array System Version 1.0...
  • Page 3 Q08+F2R2 Fibre Channel to Serial ATA II Disk Array System Hardware User Manual...
  • Page 5: Table Of Contents

    Components ......................4 Closed Front Panel ................... 4 Open Front Panel ..................... 5 Disk Tray ......................6 easyRAID Q08+F2R2 Rear View ..............7 Installing Disks ...................... 8 Making Connections ................... 10 Connecting the Host Interface ................ 10 Connecting a network ..................12 Connecting and Turning on the Power ............
  • Page 7: Preface

    Preface About this Manual This manual is designed to make the disk array system as easy to use as possible. Information contained in this document has been checked for accuracy, but no guarantee is given that the con- tents are correct. Information and specifications are subject to change without notice. Copyright Notice ©...
  • Page 8 Q08+F2R2 Serial ATA II Disk Array System Important Safety Instructions, Care and Handling Before starting, take a few minutes to read this manual. Read all of these instructions and save this manual for later reference. Protect the disk array system from extremely high or low temperatures.
  • Page 9 Q08+F2R2 Serial ATA II Disk Array System The appliance must be grounded. The disk array system is equipped with a 3-wire grounded type of power cord. This power cord will only fit into a grounded type of power outlet.
  • Page 10 Q08+F2R2 Serial ATA II Disk Array System Placement Notes • The disk array system LCD panel can be damaged by exposure to direct sunlight. Limit exposure to subdued or indirect sunlight only. • The disk array system should be used only in clean environments that are free from airborne contaminants such as dust, dirt, and smoke.
  • Page 11: Chapter 1 System Requirements

    1 System Requirements Ensure that the following requirements are met before installing the disk array system. Operating Environment • 15 cm (6-inches) of space around the disk array system for proper ventilation • ambient temperature of 5°C to 40°C (40°F to 104°F) •...
  • Page 12: Host Interface

    Fibre Channel Interface The easyRAID Q08+F2R2 has dual 2 Gbit fibre channel interfaces with SFP connectors for link- age to a fibre channel switch or host computer interface card. With the correct SFP transceiver and optical cable, the following transmission distances can be achieved.
  • Page 13: Chapter 2 Basic Configuration

    2 Basic Configuration This chapter describes disk array system connections and disk installation. Unpacking Contact your supplier if any of the following items are missing or damaged. Caution The disk array system is heavy. Be careful when lifting and moving it. Screw pack Front Panel Keys Disk Array System...
  • Page 14: Components

    Q08+F2R2 Serial ATA II Disk Array System Components Closed Front Panel Power P/S Fail Access Enter 5 6 7 Name Description Displays warning, operating, and configuration LCD panel information. Power-on indicator Indicates the disk array system power is on.
  • Page 15: Open Front Panel

    Q08+F2R2 Serial ATA II Disk Array System Open Front Panel Tray LED Indication Color Status Bule Access Green Disk Online No Disk Name Description Disk trays 1-8 Removable hot swap disk trays Front panel door Protects the disks and houses the LCD panel...
  • Page 16: Disk Tray

    Q08+F2R2 Serial ATA II Disk Array System Disk Tray Front Name Description Power/Error indicator LED Different colors indicate different disk states: • Green – Disk online • Orange – Disk full • Red – No disk This blue LED indicates that the disk is being Access indicator LED accessed.
  • Page 17: Easyraid Q08+F2R2 Rear View

    Q08+F2R2 Serial ATA II Disk Array System easyRAID Q08+F2R2 Rear View Name Description Cooling fan 1 System cooling fan. Host Port 2 Connects to the host server. (Secondary fibre channel) Host Port 1 Connects to the host server. (Primary fibre channel) RS-232 Port Connects to a VT100 terminal or equivalent.
  • Page 18: Installing Disks

    Q08+F2R2 Serial ATA II Disk Array System Installing Disks This section describes how to install disks in the disk array system. 1 Unlock the front panel door, then pull it open. Tray LED Indication Color Status Bule Access Green...
  • Page 19 Q08+F2R2 Serial ATA II Disk Array System 5 Slide the disk tray back into the empty slot (A), then slowly close the disk tray handle (B). 6 Repeat steps 2 to 5 until all of the required disks have been installed.
  • Page 20: Making Connections

    Fibre Channel Interface The easyRAID Q08+F2R2 has dual 2 Gbit fibre channel interfaces. Each interface can be used with optical or copper transceivers and cables. Follow these instructions to make optical connections. 1 Insert the LC Optical SFP transceiver (A) in to the easyRAID Q08+F2R2 FC CH 2 (secondary fibre channel) at the rear of the disk array system.
  • Page 21 Q08+F2R2 Serial ATA II Disk Array System Fibre Channel Daisy Chaining Four-port models can be daisy chained as shown in the following diagram.
  • Page 22: Connecting A Network

    Q08+F2R2 Serial ATA II Disk Array System Connecting a network Connect the network cable to the RJ-45 port at the rear of the unit. CO M UP S Connecting and Turning on the Power 1 Plug a power cable (A) to a power connector at the rear of the unit, then plug the second power supply cable into the second power connector (B).
  • Page 23: Mounting In A Rack

    Q08+F2R2 Serial ATA II Disk Array System Mounting in a Rack When the disk array system is completely set up, it can be installed in a standard 19-inch rack. Follow the instructions in this section to install the disk array system in a rack.
  • Page 24: Installing The Rail Extenders

    Q08+F2R2 Serial ATA II Disk Array System Installing the Rail Extenders Follow these instructions to fit the rail extenders if required. 1 If required, bolt the rail extenders into place as shown using the small bolts provided. 2 Slide the disk array system into the rack and bolt it into place with the supplied fixing screws.
  • Page 25: Chapter 3 Maintenance Replacing A Disk

    3 Maintenance Replacing a Disk A disk failure is indicated when the Power/Error LED at the front of the drive tray turns red and the audible alert sounds. Note Turn off the audible alert by pressing the Up and Down function but- tons on the front panel twice simultaneously.
  • Page 26: Replacing A Power Supply

    Q08+F2R2 Serial ATA II Disk Array System Replacing a Power Supply The disk array system is equipped with a Power Supply Fail Indicator LED at the front of the unit that turns red when one of the power supplies fails. The message “Power x failure” also appears on the LCD panel, where x refers to power supply 1, or 2, and an audible alert sounds.
  • Page 27 Q08+F2R2 Serial ATA II Disk Array System 4 Pull the power supply handle out. CO M UP S 5 Remove the faulty power supply by pulling the power supply handle A and pressing the release catch B at the same time.
  • Page 28: Upgrading Memory

    Q08+F2R2 Serial ATA II Disk Array System Upgrading Memory The disk array system takes a single DDR-333 184-pin DIMM with a maximum capacity of 2 GB. Follow these instructions to upgrade the memory. 1 Loosen the screws holding the controller cage in place.
  • Page 29 Q08+F2R2 Serial ATA II Disk Array System 4 Gently push the new DIMM into the socket, then push the corners of the DIMM down. The DIMM is secured by the DIMM retaining clips. Note The DIMM module will fit in only one direction. Do not force the DIMM into place.
  • Page 31: Appendix

    Appendix Hardware Specifications Item Specification Host Interface 2 Gb Fibre Channel Disk Interface SATA II, 3.0 Gb/s Dimensions 88 mm (H) x 447 mm (W) x 565 mm (D) Weight 19 Kg without disks RAID Functions • Raid levels: JBOD, 0, 1, 0+1, 3, 5, 30, 50, 6, TP, NRAID •...
  • Page 32 Q08+F2R2 Serial ATA II Disk Array System Item Specification Controller Intel i80331 64-bit RISC microprocessor Disk Interface SATA II (3.0 Gb/s) Disk Channels 8 channels Disk Interface Chipset Marvell MV88SX8050 Memory Type DDR-333 184-pin DIMM Memory Sockets Memory Size...

Table of Contents