Air free P1000 Instruction Manual

Air free P1000 Instruction Manual

Air purifier

Advertisement

Ins
ns
nstruc
uc
uction
P1000/P2000
n
n Manual
Instruction Manual
P1000/P2000

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the P1000 and is the answer not in the manual?

Questions and answers

Summary of Contents for Air free P1000

  • Page 1 Manual Instruction Manual P1000/P2000 P1000/P2000...
  • Page 2 Copyright 2005 Policon Ltd. All Rights Reserved All rights reserved. No part of this publication may be reproduced, photocopied, transmitted, transcribed, stored in a retrieval system, or translated into any lan- guage in any form or by any means without the express prior written consent of Policon Ltd.
  • Page 3: Table Of Contents

    Index Introduction Applications Airfree and Mold Technical Characteristics Airfree Description Installing and Connecting Safety Instructions How does Airfree work? Maintenance Airfree’s Independent and Effi ciency Tests FAQ - Frequently Asked Questions Warranty...
  • Page 4 Congratulations for having purchased your Airfree. Airfree air purifi ers are manufactured under license of US Patent 5,874,050, and many other patents pending worldwide. Airfree was designed with most advanced American and German technologies, to drastically destroy indoor airborne micro- organisms and reduce ozone.
  • Page 5: The Invisible Enemies

    The Invisible Enemies Most people spend around 90% of their time time indoors, at home or in the of- fi ce. The EPA – Environmental Protection Agency claims the quality of air indoors can be 100 times worse than outdoors. Some factors contribute to indoor contamination: High concentration of people in rooms increase fungus, bacteria and vi- rus development, and cross contamination...
  • Page 6: Applications

    Applications Healthy rooms with pure clean air The effi cient and noiseless Airfree technology safely destroys mold spores, bacteria, viruses and other airborne organic microorganisms. Respiratory allergies and Asthma Airfree drastically reduces airborne organic allergens and ozone, provid- ing cleaner and safer environment for allergic people. Airfree destroys mold spores, bacteria, viruses, dust mite allergens, pet dander and re- duces ozone, all kept to minimum levels.
  • Page 7 Applications Offi ces, Public Buildings Populated rooms, corridors, and elevators offer a constant contamination risk to employees and guests. This situation is aggravated by the fl ow of hazardous fungi and other microbes entering through the A/C system, and the ozone generated by computers and photocopiers. The spread of air- borne transmittable diseases can accelerate in this environment.
  • Page 8 Applications Pollens Pollens are no exception and like other microorganims are totally destroyed when passing through Airfree patented sterilizing core. After being incinerated the resulting harmless particles are released back to the environment. Ozone (O3) Ozone is a very toxic gas that according to EPA can damage lung tissue, cause chest pain, throat irritation and trigger asthma.
  • Page 9: Airfree And Mold

    Airfree and Mold Guide for Airfree installation in mold contaminated rooms 1 - Install your Airfree unit in accordance with the user manual 2 - Allow your unit to run for at least one week to achieve signifi cant airborne mold spore reduction. 3 - Clean mold infected items and surfaces, since they are a continu- ous source of new spores.
  • Page 10: Technical Characteristics

    Technical Characteristics P1000 P2000 Model Capacity 450 sq ft. (42m 550 sq. ft (51m Inside Temperature 400°F (204°C) 400°F (204°C) Electric Consumption Voltage 120V 120V Noise Totally Silent Totally Silent 2.4 lbs (1,09 Kg) 2.8 lbs (1,27 Kg) Weight height: 10.4in height: 10.4in...
  • Page 11: Airfree Description

    Airfree Description 1- Top Lid with Air outlets and Anti-Stress Light 2- Side Shells 3- On/Off Led 4- Base 5- Air Inlets 6- Power Cord 7- Anti-Stress Light Dimmer The Airfree’s anti-stress light has a esthetic effect and may be relaxing. It is pos- sible to adjust the light intensity using the dimmer at Airfree’s base.
  • Page 12: Installing And Connecting

    fl ow and Airfree effi ciency in reducing microorganisms. Airfree P1000 was designed for rooms up to 450 sq. ft. (42m²), Airfree P2000 was designed for rooms up to 550 sq. ft. (51m²). The use of just one Airfree in rooms larger than recommended will reduce Airfree effi...
  • Page 13 Installing and Connecting Airfree can only be used in rooms with minimum air volume of 330 cu. ft. (10 m3), free of obstacles. Airfree can be installed in rooms equipped with air conditioning and heating systems. However it is recommended not to place Airfree nearby them to avoid potential interference in Airfree air fl...
  • Page 14: Safety Instructions

    Safety Instructions Before plugging in Airfree slightly shake it to check for any loose parts in its interior caused by unusual transportation event. If loose parts are noticed, please return the unit to the retailer. Do not place your Airfree in direct contact with water and liquids which may pose electric shock hazard and damage to the unit itself.
  • Page 15: How Does Airfree Work? Maintenance

    How does Airfree Work? Maintenance Purifi ed Air Cooling Chamber Cold and clean air is delivered environment without signifi cant change room temperature and humidity. Sterilizing Ceramic Core Inside the ceramic core 99.99% microorganims incinerated and eliminated from the environment Air Inlets Contaminated air enters Airfree by air convection...
  • Page 16: Airfree's Independent And Effi Ciency Tests

    Airfree Independent and Effi ciency Tests AIRFREE EFFICIENCY TESTS BY INDEPENDENT LABORATORIES, INSTITUTES AND UNIVERSITIES IN FOLLOWING COUNTRIES. Reduction of Microorganisms Laboratory Local Dust Mite alergens Fungus Bacteria DerP-1 Insect R&D Limited Cambridge/UK 70,6% to 97,95% Laboratory june, 2005 SGS Natec Institute* Hamburgo/Germany Laboratory Offi...
  • Page 17: Faq - Frequently Asked Questions

    3. What is Airfree’s air cleaning capacity? Airfree P1000 was designed for rooms up to 450 sq. ft. (42m²), Airfree P2000 was designed for rooms up to 550 sq. ft. (51m²).
  • Page 18 FAQ - Frequently Asked Questions 9. Is it necessary to keep doors and windows closed? It is preferable. But opening window for 1 or 2 hours a day will not affect Airfree effi ciency. 10. Does Airfree eliminate bacteria and viruses? Yes.
  • Page 19 FAQ - Frequently Asked Questions 15. How does Airfree destroy dust mites? Mold reduction in the environment causes reduction in the mold dependant dust mite population. Airfree also destroys the harmful allergens and fungus freed by dust mite feces that trigger respiratory allergies.
  • Page 20 22. Does Airfree need fi lter replacement? 23. Does Airfree consume a lot of energy? No. Airfree’s consumption is just 45 Watts for P1000 and 48 Watts for P2000 . 24. Can Airfree heated top lid burn children? No. The top lid’s temperature ir around 179.6°F (82ºC), which is not enough to burn a child’s hand.
  • Page 21: Warranty

    Warranty Warranty Certifi cate - 2 years Model: Serial Number Client Name: Address: City: Zip Code: Phone Number. ( Purchase Date Store Name: Invoice Number: In order to obtain full warranty terms and conditions as stated above please fi ll in and return Warranty Certifi cate to Authorized Airfree distributor.
  • Page 23 Warranty This product is warranted by AIRFREE PRODUCTS, to the original purchaser to be free from defects in material and workmanship under proper use for a period of two years from date of purchase. During this period, and upon proof of purchase and date of purchase, this product will be repaired or replaced with same or similar model without charges for parts or labor (except for a USD10 charge for insurance and handling) at distributor address.
  • Page 24 AIRFREE PRODUCTS Tel.: 351 - 213 156 222 Web: www.airfree.com Mail: info@airfree.com...

This manual is also suitable for:

P2000

Table of Contents