Do you have a question about the 2050PSI and is the answer not in the manual?
Questions and answers
WILLIAM KEITH STANLEY
March 27, 2025
I don't see any view showing the back where you hook up the hose or the spray gun? the water hose keeps flying off as soon as i start it?
1 comments:
Mr. Anderson
March 27, 2025
To properly connect the hose and spray gun to the CleanShot 2050PSI and prevent the water hose from coming off, follow these steps:
1. Uncoil the high pressure hose. 2. Attach one end of the high pressure hose to the base of the spray gun and tighten by hand. 3. Attach the other end of the high pressure hose to the high pressure outlet on the pump and tighten by hand. 4. Connect a garden hose (no longer than 50 feet) to the water inlet and tighten by hand. 5. Ensure there is at least ten feet of unrestricted garden hose between the pressure washer and any shut-off valve. 6. Run water through the garden hose for 30 seconds to clear debris. 7. Turn on the water. 8. Squeeze the spray gun trigger to purge air and impurities from the pump.
Make sure all hoses are attached before starting the engine. Use only cold water (under 100°F).
This answer is automatically generated
Summary of Contents for CleanShot 2050PSI
Page 1
Llame: Línea Directa del Lavador a Presión - 1-800-743-4115 M-F 8-5 CT CleanShot™ is a trademark of Briggs & Stratton Power Products. CleanShot™ es una marca registrada de Briggs & Stratton Power Products. BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC JEFFERSON,WISCONSIN, U.S.A.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer TABLE OF CONTENTS SAFETY RULES Safety Rules........2-4 This is the safety alert symbol.
Page 3
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer DANGER WARNING Running engine gives off carbon monoxide, an Fuel and its vapors are extremely flammable an odorless, colorless, poison gas. explosive. Some chemicals or detergents may be harmful if...
Page 4
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer WARNING CAUTION Excessively high or low operating speeds increase risk Running engines produce heat and hot exhaust of injury and damage to pressure washer.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer KNOW YOUR PRESSURE WASHER Read this owner’s manual and safety rules before operating your pressure washer. Compare the illustrations with your pressure washer to familiarize yourself with the locations of various controls and adjustments.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer Required Assembly Tools NO Tools Required for Assembly ASSEMBLY PREPARING PRESSURE IMPORTANT: Read entire owner’s manual before you WASHER FOR USE attempt to assemble or operate your new pressure washer.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer Connect Hose and Water Supply to Run water through your garden hose for 30 seconds to clean out any debris. Pump IMPORTANT: DO NOT siphon standing water for the IMPORTANT: To avoid pump damage, you must assemble water supply.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer HOW TO USE YOUR Engage safety latch to spray gun trigger (Figure 5). Figure 5 — Spray Gun with Safety Latch Engaged PRESSURE WASHER...
Page 9
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer If you get spray nozzle too close, especially using high Figure 6 — Adjusting Nozzle for Pressure pressure mode, you may damage surface being cleaned.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer Attach the brush with the adapter to the spray gun. Allow detergent to "soak in" for 3-5 minutes before Tighten by hand (Figure 10).
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer Pull trigger on spray gun and hold. Nozzle Maintenance When water supply is steady and constant, engage A pulsing sensation felt while squeezing the spray gun safety latch.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer Reinstall orifice and in-line filter into nozzle extension. Use a 8mm allen wrench to remove black pump oil DO NOT overtighten orifice with allen wrench.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer PREPARING THE UNIT NOTE: PumpSaver is available as an optional accessory. It is not included with the pressure washer. Contact the FOR STORAGE nearest authorized service center to purchase PumpSaver.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer TROUBLESHOOTING Problem Cause Correction Nozzle in low pressure mode. Pull nozzle backward for high pressure mode. Water inlet is blocked. Clear inlet. Inadequate water supply.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer EXPLODED VIEW AND PARTS LIST – MAIN UNIT Item Part # Description Item Part # Description 194494GS ASSY, BASE 193482GS B5693GS HOSE 194344DGS ASSY,Wand, Hi-Lo...
Page 17
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 CleanShot™ 2050 PSI Pressure Washer EXPLODED VIEW AND PARTS LIST – PUMP Item Part # Description Item Part # Description 19 190571GS CAP, Oil A NSP ASSY, CASE, PISTON...
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY Effective January 1, 2003 replaces all undated Warranties and all Warranties dated before January 1, 2003 LIMITED WARRANTY Briggs &...
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ TABLA DE CONTENIDOS REGLAS DE SEGURIDAD Reglas De Seguridad ....... . 20-22 Éste es el símbolo de alerta de seguridad.
Page 21
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ PELIGRO ADVERTENCIA Al motor funcionar, se produce monóxido de La gasolina y sus vapores son extremadamente carbono, un gas inodoro y venenoso.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ ADVERTENCIA PRECAUCIÓN El lavadora de presión produce un rocío alto de la presión Los motores en funcionamiento producen calor y gases de escape a altas temperaturas. La temperatura cuál riesgo de aumentos de la herida y dañe a la unidad.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ CONOZCA SU MAQUINA LAVADORA DE PRESION Lea el manual del propietario y las reglas de seguridad antes de poner en marcha su máquina lavadora a presión.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ Herramientas Requeridas de la Asamblea NO herramientas requeridas de la asamblea MONTAJE PREPARANDO EL LAVADOR A PRESIÓN PARA SU USO IMPORTANTE: Lea totalmente el manual del propietario antes que intente ensamblar u operar su lavador a alta presión.
Page 25
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ Conecte la Manguera y el Suministro de Haga correr el agua a través de la manguera de su jardín por 30 segundos para limpiar cualquier escombro que se Agua a la Bomba encuentre en ella.
Page 26
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ CÓMO USAR SU MÁQUINA Coloque el pasador de seguridad al gatillo de la pistola rociadora (Figura 19). LAVADORA A PRESIÓN Figura 19 — La Pistola Rociadora con el Pasador de Si tiene problemas operando su máquina lavadora a presión, por...
Page 27
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ Para una limpieza más efectiva, mantenga la boquilla de Figura 20 — Ajustar la Presión de Aspersión rociado de 8 a 24 pulgadas de la superficie de limpieza.
Page 28
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2000 PSI de SpeedClean™ Para conectar el cepillo de servicio a la pistola de rociado: Aplique el detergente sobre la superficie seca, comenzando Coloque el pasador de seguridad al gatillo de la pistola rociadora. en la parte inferior del área y dirigiéndose hacia arriba, utilizando movimientos largos, parejos y superpuestos.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ ESPECIFICACIONES MANTENIMIENTO DE LA Presión de Salida ..2050 PSI MAQUINA LAVADORA A Promedio de Flujo ..2.0 galones por minuto (gpm) PRESION Detergente .
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ Cuándo el agua es constante y constante, compromete el Apague el motor y apague el suministro de agua. picaporte de la seguridad.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ Mantenimiento de los Anillos 'O' Figura 28 - Cambio del Aceite de la Bomba Compre una O–Juego de Mantenimiento de Anillo, el artículo numera 191922GS, en avisando el más cercano servicio autorizado...
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ PREPARANDO LA UNIDAD PARA PRECAUCIÓN SU ALMACENAMIENTO Usted deberá proteger su unidad de las temperaturas de congelamiento. El agua no debe permanecer en la unidad por un largo periodo de tiempo.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ NOTAS www.mymowerparts.com...
Page 34
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ NOTAS www.mymowerparts.com...
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 Lavadora de Presión 2050 PSI de CleanShot™ REPARACION DE AVERIAS Problema Causa Solución La boquilla está en el modo de baja Mueva la boquilla hacia atrás para el presión.
Briggs & Stratton Generac Generator Discount Parts Call 606-678-9623 or 606-561-4983 POLÍTICA DE GARANTÍA PARA EL PROPIETARIO DE EQUIPOS BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC Vigente a partir de Enero 1, 2003 reemplaza todas las Garantías previas sin fecha y todas las Garantías fechadas antes de Enero 1, 2003. GARANTÍA LIMITADA Briggs &...
Need help?
Do you have a question about the 2050PSI and is the answer not in the manual?
Questions and answers
I don't see any view showing the back where you hook up the hose or the spray gun? the water hose keeps flying off as soon as i start it?
To properly connect the hose and spray gun to the CleanShot 2050PSI and prevent the water hose from coming off, follow these steps:
1. Uncoil the high pressure hose.
2. Attach one end of the high pressure hose to the base of the spray gun and tighten by hand.
3. Attach the other end of the high pressure hose to the high pressure outlet on the pump and tighten by hand.
4. Connect a garden hose (no longer than 50 feet) to the water inlet and tighten by hand.
5. Ensure there is at least ten feet of unrestricted garden hose between the pressure washer and any shut-off valve.
6. Run water through the garden hose for 30 seconds to clear debris.
7. Turn on the water.
8. Squeeze the spray gun trigger to purge air and impurities from the pump.
Make sure all hoses are attached before starting the engine. Use only cold water (under 100°F).
This answer is automatically generated