1. Always use a defoamer when foaming occurs to prevent vacuum motor damage.
2. Keep machine from rain and snow, extremes in temperatures, and store in a heated
location. Use the machine indoors. Do not use outdoors.
3. Never use the machine without the pre-filter bag installed.
02-02-2010
1

Advertisement

Table of Contents
loading

Summary of Contents for U.S. Products FLOOD KING 120

  • Page 1 ® FLOOD KING 120V INFORMATION & OPERATING INSTRUCTIONS CAUTION: DO NOT OPERATE MACHINE UNTIL YOU HAVE READ ALL SECTIONS OF THIS INSTRUCTION MANUAL IMPROPER USE OF THE MACHINE WILL VOID THE WARRANTY 1. Always use a defoamer when foaming occurs to prevent vacuum motor damage. 2.
  • Page 2: Important Safety Instructions

    IMPORTANT SAFETY INSTRUCTIONS This machine is only suitable for commercial use, for example in hotels, schools, hospitals, factories, shops and offices other than normal residential housekeeping purposes. When using any electrical appliance, basic precautions should always be followed, including the following: NOTE: Read all instructions before using this machine.
  • Page 3: Maintenance

    INSPECTION: Carefully unpack and inspect your FLOOD KING for shipping damage. Each machine is tested and inspected before shipping. Any damage incurred during shipping is the responsibility of the carrier. You should notify the carrier immediately if you notice damage to the box or to the machine or parts. MAINTENANCE: Prior to each job, inspect the recovery tank pre-filters, the stainless steel in-line filters, the float, and the drain hose to make sure every thing is clean and able to function properly.
  • Page 4: Vacuum Operation

    SET-UP: Connect the vacuum/recovery hose to the vacuum inlet hose barb on the recovery tank. Connect the dump hose to the hose fitting on the rear of the machine. Check filters. Put the lid on the recovery tank. Plug the machine into a grounded outlet. VACUUM OPERATION: A switch is provided for each vacuum motor.
  • Page 6: Part List

    FLOOD KING PART LIST 120V Item Part No Description Item Part No Description 2077 Hose Barb, 1-1/2” 46B 1466 Hose barb/elbow 1463 Eblow, ABS, 45 degrees (3) 1468 Hose, 3/4” ID X 3” 1464 Bushing, 2” slip “T,” brass SUBVT-25 Tank, recovery Elbow, brass, 45 degree 4A 2070B...
  • Page 7: Specifications

    SPECIFICATIONS: POWER CORD: One, 25 ft, 12 gauge, 3-wire with hospital grade plug 13 Amps, total POWER CONSUMPTION: RECOVERY CAPACITY: 9 gallon VACUUM INTAKE HOSE: 2 inch X 25 ft Two, 3-stage VACUUM MOTOR(s): WATER LIFT/CFM: 100 inches / 170 cfm 520 AW in operational range AIR WATTS: OVERFLOW PROTECTION:...
  • Page 8 FLOOD KING ® 120V NOTES: 208-772-0573 • 800-257-7982 • FAX: 208-772-0577 : http://www.usproducts.com VISIT US AT...