(ALC5 Series)

Features

• 5 year warranty
• Damp location rated

BEFORE YOU BEGIN

Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK
• Turn power off before inspection, installation or removal.
• Properly ground electrical enclosure.
RISK OF FIRE
• Follow all NEC and local codes.
• Use only UL or IEC approved wire for input/output connections.
Minimum size 18 AWG.
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation. CAN ICES-3 (A)/NMB-3(A)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses,
and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the
interference at his own expense.
Save These Instructions
Use only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer.

Prepare Electrical Wiring

Electrical Requirements

• The LED driver must be supplied with 120-480 VAC, 50/60 Hz per product label and connected to an individual
properly grounded branch circuit, protected by a 15 or 20 ampere circuit breaker.

Grounding Instructions

• The grounding and bonding of the overall system shall be done in accordance with National Electric Code
(NEC) Article 600 and local codes.
imagination at work
LED Luminaire
WARNING/AVERTISSEMENT
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation avant d'inspecter, installer ou déplacer le luminaire.
• Assurez-vous de correctement mettre à la terre le boîtier d'alimentation électrique.
RISQUES D'INCENDIE
• Respectez tous les codes NEC et codes locaux.
• N'utilisez que des fils approuvés par UL ou IEC pour les entrées/sorties de
connexion. Taille minimum 18 AWG.
Installation Guide

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Albeo and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for GE Lighting Albeo

  • Page 1 Installation Guide Lighting Albeo LED Luminaire Linear Lighting (ALC5 Series) Features • 5 year warranty • Damp location rated BEFORE YOU BEGIN Read these instructions completely and carefully. WARNING/AVERTISSEMENT RISK OF ELECTRIC SHOCK RISQUES DE DÉCHARGES ÉLECTRIQUES • Turn power off before inspection, installation or removal.
  • Page 2 Unit Installation ALC5 Fixture Weight Carefully unpack unit and properly inspect for defects before installing. Wear work gloves to prevent dirt and oil from being Size 120-277V 347/480V transferred to the luminaire. 4 ft. fixture 8.5 lbs. 11.5 lbs. Choose a mounting method: chain, cable, rod, or surface mount. 8 ft.
  • Page 3 Surface Mounting Junction box Ceiling Loosen screws Move mounting brackets to ends Open LED lightbar Position the two mounting brackets at the ends of Loosen screws on side of fixture and unhinge LED the fixture and tighten. Attach the fixture to ceiling lightbar from fixture.
  • Page 4 A) Conduit B) Power cord Option: power input from side – Remove knockout 120-277V: Connect the green (ground), black (line) in endcap and A) Install 1/2” conduit, or B) install and white (neutral) wires of the AC line to the AC power cord with strain relief.
  • Page 5 (1-888-69-43-533) GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. The GE brand, logo, and Albeo are trademarks of the General Electric Company. © 2015 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.

Table of Contents