  • Page 1 ’ PERATOR ANUAL Usage and care of your AVE and CES device...
  • Page 2: Otice To Ealth Are Roviders

    (prescription or recreational), d) are under the influence of alcohol, e) have had any head injuries, should not use the DAVID Delight Pro unless under the supervision of a health care provider qualified in the safe detection of seizures. OTICE TO...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS ............I OTICE TO EALTH ROVIDERS NSIDE RONT OVER INTRODUCTION ........................1 ..........................1 OMPONENT ....................... 1 DDITIONAL CCESSORIES ABOUT CES ..........................2 SESSION CONTROLS ......................3 ..............................3 OLUME ............................3 NTENSITY ..........................3 ELECTION ........................3 EARTBEAT ELECTION ........................
  • Page 4 TABLE OF CONTENTS WARNINGS ......................... 16 (AVE) ..................16 UDIO ISUAL NTRAINMENT (CES) ......................17 RANIO LECTRO ............................17 RECAUTIONS WARRANTY AND CARE ....................18 .......................18 ETURNING FOR EPAIRS ............19 NITED TATES AND NTERNATIONAL USTOMERS .......................19 ARE AND AINTENANCE .......................19 ISCLAIMER OF IABILITY TROUBLESHOOTING.......................
  • Page 5: Introduction

    The portability of the DAVID Delight Pro lends itself to easy travel (airport X-ray machines will not harm the DAVID Delight Pro). In order to obtain the maximum enjoyment and benefits from your DAVID Delight Pro, please read this operator's manual and the companion DAVID AVE User Guide thoroughly.
  • Page 6: About Ces

    ABOUT CES As far back as the first century, the Greeks and Romans used the electric eel, a variety of the “Torpedo Fish” for electrical stimulation. The electric eel was used well into the 19th century, even after the invention of electronic stimulation devices.
  • Page 7: Session Controls

    SESSION CONTROLS VOLUME The volume level affects both tones and the heartbeat together. There are 30 volume levels. To adjust the volume, press and release or press and hold the buttons. The graph will display the volume level. The volume cannot be adjusted during Soft Off™.
  • Page 8: Ave Operating Instructions

    AVE OPERATING INSTRUCTIONS SETUP The headphones connect to the headphone output jack ( ). When using an Extra User Package (sold separately), connect the 3.5mm splitter cable to the Delight Pro and connect each set of headphones to the splitter cable. Please ensure that you have the side marked “L”...
  • Page 9: Turn On/Turn Off

    AVE OPERATING INSTRUCTIONS TURN ON/TURN OFF Press and hold the power button ( ) until the power LED turns on. The graph (between the VOL and INT controls) will display the battery level when you first turn on the unit (see Battery Level). If no session is selected within two (2) minutes, the Delight Pro will turn off.
  • Page 10: Ces Operating Instructions

    CES OPERATING INSTRUCTIONS SETUP To use the CES feature of the Delight Pro, the unit must be powered from a 9V battery. If a 9-volt adapter is plugged in, the CES will be disabled as a safety precaution against electrical shock. Make sure to disconnect any adapter before using CES.
  • Page 11: Ces Intensity

    CES OPERATING INSTRUCTIONS CES INTENSITY The CES stimulus level can be adjusted at any time using the CES buttons. The graph displays the current CES stimulus level as you are adjusting it. The top-most lit LED will blink to indicate the level is being adjusted. The intensity of the CES stimulus should be adjusted to a level so that the stimulus is only mildly noticeable.
  • Page 12: Sound Sync Sessions

    SOUND SYNC SESSIONS The Delight Pro has the ability to use sound to run a special session for relaxation and lucid dreaming effects. To start a sound sync session, connect your audio device (eg CD or MP3 player) to the audio in jack ( ) with the 3.5mm stereo patch cord provided.
  • Page 13: User Designed Sessions

    USER DESIGNED SESSIONS The User Designed session group ( ) has been left blank for storing additional, or user created sessions. This provides space for five (5) standard sessions and one (1) sound sync session. Sessions are created using the DAVID Session Editor (sold separately).
  • Page 14: Quick Start (Ave)

    QUICK START (AVE) Find a comfortable spot Sessions are an average of 30 minutes. Find a place where you won’t be disturbed. Dark, quiet places are better. Stay hydrated Drink a glass of water at least 15 minutes before your session. Staying hydrated will help to prevent headaches or feeling groggy.
  • Page 15: Icon Descriptions

    ICON DESCRIPTIONS Icon Control Power Turn the Delight Pro on/off Initiate manual Soft Off™ Start Session/Tone and Heartbeat Control Starts the currently selected session Cycle through the available tones Turn the heartbeat on/off Volume Control Increase or decrease the loudness of the tones and heartbeat Intensity Control Increase or decrease the brightness of the eyeset lights...
  • Page 16 ICON DESCRIPTIONS Icon Session Group ( see page 13 for descriptions ) Energize Meditate Brain Booster Sleep Feeling Better User Designed [12]...
  • Page 17: Delight Pro Sessions

    DELIGHT PRO SESSIONS DO NOT use CES if you have a heart pacer. The electrical signals may cause the pacer to malfunction, leading to serious injury or death. Energize Sessions to wake you up and stimulate you 24 min 14Hz Used to achieve relaxed attention.
  • Page 18 DELIGHT PRO SESSIONS Brain Booster Sessions to help you focus and concentrate SMR for Reading 20 min 13.5-15Hz Use with a set of Tru-Vu Omniscreen Viewhole eyesets (sold separately) to improve attention and alertness while reading. L 13.5Hz SMR/Beta 24 min R 18Hz A gentle and entraining session that helps to focus mental functioning and memory.
  • Page 19 DELIGHT PRO SESSIONS Feeling Better Sessions to help your mood and reduce stress L 10Hz Mood Booster 1 30 min R 18Hz Settles down negative emotions from the right brain while stimulating the left brain to rebalance alpha asymmetry. L 10Hz Mood Booster 2 42 min R 18Hz...
  • Page 20: Warnings

    We recommend that all persons who have a history of epilepsy, photic epilepsy or have ever had a seizure of any kind not use the DAVID Delight Pro unless under the supervision of a health care professional who is qualified in the safe detection of seizures.
  • Page 21: Cranio -Electro Stim (Ces)

    A double blind study showed that CES works at sub-threshold (below feeling) level. RECAUTIONS Traumatic Childhood Experiences - The DAVID Delight Pro can cause the release of suppressed memories. If traumatic memories surface during or after a session, be certain to seek appropriate support. Somnatic Shock...
  • Page 22: Warranty And Care

    Should this unit become inoperative within the one-year period, it will be repaired or replaced at our option, without charge. Any postage, insurance and shipping costs incurred in returning the DAVID Delight Pro for service are the responsibility of the customer.
  • Page 23: For United States And International Ustomers

    Delight Pro whether willful or negligent either to person or damage to property of the purchaser, employees of the purchaser, persons designated by the purchaser for training in the use of the DAVID Delight Pro, clients or patients of the purchaser, any other person, designated by the purchaser for any purpose, prior to or subsequent to acceptance, delivery, installation and use of the DAVID Delight Pro either at the premises of Mind Alive Inc., or the premises of its...
  • Page 24: Troubleshooting

    TROUBLESHOOTING What Graph blinks a single bar, Replace the battery or use a 9-volt DC power then the Delight Pro adapter turns off Delight Pro does not turn Replace the battery or use a 9-volt DC power adapter Lights in eyeset are Ensure the eyeset cable is fully plugged into active on the left side the glasses and the...
  • Page 25: References

    REFERENCES Budzynski, T. & Budzynski, H. (2001) Brain brightening – preliminary report. In house manuscript, Mind Alive Inc. Fox, P. and Raichle, M. (1985) Stimulus rate determines regional blood flow in striate cortex. Annuls of Neurology, 17(3), 303-305. Shealy, N., Cady, R., Cox, R., Liss, S., Clossen, W., and Veehoff, D. (1989). A comparison of depths of relaxation produced by various techniques and neurotransmitters produced by brainwave entrainment.
  • Page 26: Notes

    NOTES ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ ____________________________________________________________________________________________ [22]...