Download Print this page

Troubleshooting - Earlex Pro-Steam LCS150NA Operating Instructions Manual

Advertisement

Available languages

Available languages

PS0176 0507
21/5/08
There is a safety thermal cut-out device
fitted to the unit. If the unit is allowed to boil dry
this will operate and prevent further use. Switch
the unit off and allow it to cool for at least 5
minutes, refill with water and then switch on
again - the thermal cut-out should automatically
re-set. If this has not re-set allow a further
cooling period.
When you have finished using the unit allow
any remaining water to cool and then empty
the unit. We recommend flushing the tank out
with clean water before storing. NEVER
LEAVE WATER IN THE UNIT WHILST
BEING STORED.
Radiator Cap
To fit - screw onto the filler neck hand tight. Do
not overtighten.
To remove - ensure unit is switched off and has
stopped boiling. Wait for 5 minutes. Slowly
unscrew the cap, any remaining trapped steam
will be released from beneath the cap. Caution
- steam is very hot -wear a glove and keep
face clear. Refill to the level indicator as before
and follow above instructions.
DANGER FROM STEAM.
Accessories
A range of accessories is available for use with
your Earlex Professional Steamer,
SSP SMALL STEAM PLATE
For stripping small awkward areas. Plate size 6"
x 3".
PPF1 PERFORATING TOOL
Porcupine Perforator for even faster removal of
wallcoverings. Porcupine perforates the paper
and allows steam to penetrate faster. Ideal for
vinyls, painted coverings and textured coatings.
Earlex professional steamers are guaranteed for six (6) months for rental purposes and one year for
ordinary use from date of purchase against defects in workmanship and materials.
Removal of grounding pin voids warranty.
NOTE: The warranty shall NOT apply if the unit has been tampered with, when repairs or attempted
repairs have been made by unauthorized persons, or where an item has been subject to misuse,
abuse, accident or damage in transit. No charges will be accepted for unauthorized parts, repairs or
services.
IN NO EVENT SHALL THE COMPANY BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGE.
Some States do not allow limitations on how long an implied warranty lasts and some States do not
allow the exclusion or limitation of incidental or consequential damages, so part or all of the above
limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you
may also have other rights which vary from State to State.
4:03 pm
Page 4
ONE YEAR HOME USE WARRANTY
Other Uses
The steamers can also be used to:
G
Remove Artex®.
G
Lift stuck down vinyl tiles.
G
Sterilise soil.
G
Kill garden weeds.
TROUBLE SHOOTING
Unit Fails to Boil
G
The thermal cut-out has operated. Switch
off, allow to cool, refill with water then switch
on again.
G
If using an extension lead - check that the
thermal re-set button on the extension lead
has not tripped out. Check that the extension
lead is rated at a minimum of 15 amps.
If the unit still will not operate return the unit to
the dealer or authorised agent to check the
thermal fuse link and element. ONLY
QUALIFIED ELECTRICIANS SHOULD
UNDERTAKE THIS WORK.
Unit keeps cutting out
G
Check that water is above minimum level.
G
Check that the extension lead is rated at
15 amps minimum and fully unwound.
G
Check that no additives have been used.
Steam escaping from Pressure Cap
G
Check for blockages in hose or steam plate.
G
Clean seating around cap area.
Descaling
To maintain peak performance of the unit,
particularly in areas of hard water, it may be
necessary to descale the element in the unit.
Proprietary descaling products can be used,
always follow the manufacturers instructions.
4

Advertisement

loading

This manual is also suitable for:

Steammaster lmb 150na