  • Page 1: Installation Guide

    EL326 Industrial Ethernet Managed Switch Installation Guide Revision: 11 June 2013 www.sixnet.com...
  • Page 2 This page intentionally left blank. EL326 Installation Guide Rev 11-Jun-13 Page 2 of 32...
  • Page 3 Management Guide Installation Guide Industrial Ethernet Switch Layer 3 with 26 Ports: 20 10/100/1000BASE-T Ports  4 Combination 10/100/1000 SFP Ports  2 10GB Expansion Ports  2 high-speed stacking ports  EL326 Installation Guide Rev 11-Jun-13 Page 3 of 32...
  • Page 4: About This Guide

    Also, as part of the switch’s software, there is an online web-based help that describes all management related features. Revision History First release. Copyright & Trademarks Copyright 2012 Sixnet, Inc.. All Rights Reserved. Note: All information in this document is subject to change without notice. EL326 Installation Guide Rev 11-Jun-13 Page 4 of 32...
  • Page 5 (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, Sixnet disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application.
  • Page 6: Fcc Statement

    Notice: Changes or modification not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment. Industry Canada Statement This device complies with the limits of Industry Canada per ICES-003. Operation is subject to the following two conditions: EL326 Installation Guide Rev 11-Jun-13 Page 6 of 32...
  • Page 7 This device must accept any interference received, including interference that may cause undesired operation.  ce dispositif peut ne pas causer l'interférence nocive, et  ce dispositif doit accepter n'importe quelle interférence reçue, y compris l'interférence qui peut causer l'opération peu désirée. EL326 Installation Guide Rev 11-Jun-13 Page 7 of 32...
  • Page 8: Warranty Statement

    In no event shall Sixnet be liable for any loss of profits, loss of use of facilities or equipment, or other indirect, incidental or consequential damages.
  • Page 9: Table Of Contents

    Page 16 Section 5 Communication Wiring Page 20 Section 6 LED Indicators Page 24 Section 7 Technical Specifications Page 26 Section 8 Hi-Pot Testing Page 28 Section 9 Service Information Page 30 EL326 Installation Guide Rev 11-Jun-13 Page 9 of 32...
  • Page 10: General Information

    Section 1 General Information The Sixnet EL326 is a 26 port industrial Ethernet managed switch designed to meet the Overview extreme requirements of power substations, traffic control, railway and other harsh environments. It combines the high performance and security of an enterprise-class switch with rugged packaging and protected circuitry to meet the needs of the most demanding applications.
  • Page 11 These industrial Ethernet Switches meet the following standards plus others: Compliances (some qualifications may be pending – contact Sixnet for the latest information) Sixnet Inc. is an ISO9001:2008 certified company (FM 65232) since 1996. These devices are designed, developed and manufactured per an ISO9001 quality management system. Electrical safety...
  • Page 12: Installation And Mounting

    Make sure to read Section 3 regarding thermal considerations before installing your switch. The above image shows an EL326 in front style arrangement (ports in front and power in the back) mounted in a typical 19” rack, prior to wiring.
  • Page 13 For the most durable mounting you can use two brackets on each side (as shown in the image above). This is ideal for applications requiring the highest shock and vibration resistance. EL326 Installation Guide Rev 11-Jun-13 Page 13 of 32...
  • Page 14 (set of 2) (set of 2) Optional 23” bracket Optional 23/24” bracket Part #: EK1-BRCKT-23 Part #: EK1-BRCKT-2324 (set of 2) (set of 2) Optional wall bracket Part #: EK1-BRCKT-WALL (set of 2) EL326 Installation Guide Rev 11-Jun-13 Page 14 of 32...
  • Page 15 Note: AutoCAD and other drawings are available on the CD or at: www.sixnet.com Mechanical Dimensions for the EL326 and Brackets EL326 Installation Guide Rev 11-Jun-13 Page 15 of 32...
  • Page 16: Thermal Considerations

    Section 3 Thermal Considerations The EL326 switches are designed to operate from -35 to +80˚C when they are installed Overview properly. The switch is cooled via conduction and radiation. There are no fans. Instead there are various heat-sinks inside the switch to conduct the heat from the components to the heavy- gauge aluminum case.
  • Page 17: Power Wiring

    P1 input and supply. Only if P1 fails is power drawn from the P2 backup input and supply. Note: These default modes of operations can be changed at the factory. Contact Sixnet for details.
  • Page 18 For the highest electrical safety the EL326 switches are provided with several grounding Safety points. First, there are two green ground Grounding Two #10-32 Screws screws (see images) that attach directly to the switch case. These screws can be used for NEBS Compliant to provide a NEBS compliant safety ground.
  • Page 19 The “D” option power inputs are reverse polarity protected. This means that if you swap the Reverse Polarity + and – leads then the switch will not be damaged. However, the switch will not operate Protection when wired this way. EL326 Installation Guide Rev 11-Jun-13 Page 19 of 32...
  • Page 20 A switch or circuit-breaker must be included in the installation. 2. The switch or circuit-breaker must be suitably located and easily reached. 3. The switch or circuit-breaker must be marked as the disconnecting device for the equipment. EL326 Installation Guide Rev 11-Jun-13 Page 20 of 32...
  • Page 21: Communication Wiring

    RJ45 (copper) Ethernet ports, SFP (pluggable) Ethernet ports and console (serial RS232) ports. The EL326 has 24 Gigabit RJ45 copper ports that accept 10/100/1000 Mbps twisted pair Gig RJ45 cabling. Use data-quality (not voice-quality) twisted pair cable rated category 5E (or better) with Ports 1-24 standard RJ45 connectors.
  • Page 22 The RJ45 ports will auto-sense for Full or Half duplex operation, while the fiber ports default to Duplex full duplex operation or can be configured for Full or Half duplex. Refer to the software user Operation manual for details on the software configuration options. EL326 Installation Guide Rev 11-Jun-13 Page 22 of 32...
  • Page 23 “ring” or “closed-loop.” The closed- loop cable provides a redundant path for the stack link, so if one link fails, stack communications can still be maintained. EL326 Installation Guide Rev 11-Jun-13 Page 23 of 32...
  • Page 24 6. The Module LED on the switch’s front panel should turn green to confirm that the module is correctly installed and ready to use. EL326 Installation Guide Rev 11-Jun-13 Page 24 of 32...
  • Page 25: Led Indicators

    Section 6 LED Indicators The EL326 switches have: Overview  1 Communication LED for each port  3 Power LEDs (P1, P2 and PWR)  1 “OK” output LED  1 Diagnostic LED  1 Stack Link LED  1 Stack Master LED ...
  • Page 26 Flashing Amber System in standalone mode. An expansion module is installed and operating normally. Green Module LED An expansion module is installed but has failed. Amber There is no module installed. EL326 Installation Guide Rev 11-Jun-13 Page 26 of 32...
  • Page 27: Technical Specifications

    Section 7 Technical Specifications These specifications are subject to change. Contact Sixnet for the latest details. Refer to the Technical software user manual or datasheet for complete software specifications. Specs ETHERNET PERFORMANCE SECURITY   26 total Ethernet ports plus 2 expansion bays Enable / disable ports ...
  • Page 28 Safety: UL508 /ANSI / ISA12.12.01 / CSA C22.2 No. MECHANICAL 142 and No. 213; UL temperature  Rack or wall mounting: specs: EL326-AA/AO-1, T4 @ 80C EL326-DD/DO-1, 1U rack mount (19” brackets included) T4 @ +75C Optional 23”, 24", EIA, WECO, ETSI and wall  IEC61010-1, CE ...
  • Page 29: Hi-Pot Testing

    Hi-Pot Test Step 2 A. Contact Sixnet and ask to be sent a complimentary “hi-pot slot card”. B. Use a credit-card-sized plastic card (without raised lettering so not an actual credit card), laminated business card or other similar plastic card. The dimensions should be as shown in the diagram below.
  • Page 30 Caution: Make sure to remove the card when you are done testing. If you leave the card in place during normal operations then your switch will not be fully protected from surges. EL326 Installation Guide Rev 11-Jun-13 Page 30 of 32...
  • Page 31: Service Information

    Section 9 Service Information We sincerely hope that you never experience a problem with any Sixnet product. If you do Service need service, call Sixnet at (518) 877-5173 and choose the option for technical support. A Information trained specialist will help you to quickly determine the source of the problem. Many problems are easily resolved with a single phone call.
  • Page 32 This page intentionally left blank. EL326 Installation Guide Rev 11-Jun-13 Page 32 of 32...